Making the most of pharmacy technicians.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M L Alexander.
Explore the source record for details and available documents.
Implant impression copings reduce access to prepared teeth during the impression-making process. If the impression copings and teeth are in close proximity, it may be difficult to extrude impression material circumferentially around the margins of the tooth preparations. A technique is described that allows the impressions of the prepared teeth to be made without the implant impression copings interfering. The advantages and disadvantages of the technique are discussed.
BACKGROUND: Although approximately 2,000 medical practice guidelines have been proposed, few have been successfully implemented and sustained. We hypothesized that we could develop and institute practice guidelines to promote more appropriate use of costly anesthetics, to generate and sustain widespread compliance from a large physician group, and to decrease costs without adversely affecting clinical outcomes. METHODS: A prospective before and after comparison study was performed at a tertiary care medical center. Clinical outcomes data and times indicative of perioperative patient flow were collected on the first of two sets of patients 1 month before discussion of practice guidelines. Practice guidelines were developed by the physicians and their associated care team for the intraoperative use of anesthetic drugs. A drug distribution process was developed to aid compliance. Clinical outcomes data and times indicative of perioperative patient flow were collected on the second set of patients 1 month after institution of practice guidelines. Hospital drug costs and adherence to guidelines were noted throughout the study period and for each of the following 9 months by querying the database of an automated anesthesia record keeper. RESULTS: A total of 1,744 patients were studied. Drug costs decreased from 56 dollars per case to 32 dollars per case as a result of adherence to practice guidelines. Perioperative patient flow was minimally affected. Time (mean +/- SD) from end of surgery to arrival in the post-anesthesia care unit (PACU) increased from 11 +/- 7 min before the authors instituted practice guidelines to 14 +/- 8 min after practice guidelines (P < 0.0001). Admission of inpatients to the PACU receiving monitored anesthesia care increased from 6.5 to 12.9% (P < 0.02). Perioperative patient flow and clinical outcomes were not otherwise adversely affected. Compliance and cost savings have been sustained. CONCLUSIONS: This study is an example of a successful physician-directed program to promote more appropriate utilization of health care resources. Cost savings were obtained without any substantial changes in clinical outcomes. Institution of similar practice guidelines should result in pharmaceutical savings in the range of 50% at tertiary care centers around the country, with a slightly smaller degree of savings expected at institutions with more ambulatory surgery.
Investigations using ion trap devices for analytical atomic spectroscopy purposes have focused on the use of an inductively coupled plasma (ICP) ion source with ion trap mass spectrometric (ITMS) detection. Initial studies were conducted with an instrument assembled by simply appending an ion trap as the detector to a fairly conventional ICP/MS instrument, i.e. leaving an intermediate linear quadrupole between the plasma source and the ion trap. The principal advantages found with this system include the destruction of nearly all problematic and typical ICP/MS polyatomic ions (e.g., ArH(+), ArO(+), ArCl(+), Ar(2)(+), etc) and a dramatic reduction of the primary plasma source ion, Ar(+). These results prompted the development of a second-generation plasma source ion trap instrument in which direct coupling of the ICP and ion trap has been effected (i.e. no intermediate linear quadrupole); the same performance benefits have been largely preserved. Initial operation of this instrument is described, characterized, and compared to the originally described ICP/ITMS and conventional ICP/MS systems. In addition, experiments aimed at improving ICP/ITMS sensitivity and selectivity using broadband resonance excitation techniques are described. Finally, the potential for laser optical detection of trapped ions for analytical purposes is speculated upon.
The mutation rate was determined for mature sperm at eight specific gene loci on the third chromosome of Drosophila melanogaster using the low ion density radiations of 22 Mev betatron X-rays. A dose of 3000 rads of betatron X-rays produced a mutation rate of 4.36 X 10(-8) per rad/locus. Among the mutations observed, 66% were recessive lethals and 34% viable when homozygous. Only one of the 24 viable mutations was associated with a chromosome aberration. Among the 47 recessive lethals, no two-break aberrations were detected in 48.9% of the lethals, deletions were associated with 42.2%, inversions with 6.7% and translocations with 2.2%.-When these genetic results are compared to those for 250 KV X-rays, the mutation rate for betatron treatments was slightly lower (.76), the recessive lethal rate among induced mutations was higher, and the chromosome aberrations among lethal mutations were slightly lower than with 250 KV X-rays. Although the two types of irradiations differ by an ion density of approximately ten, the amount and types of inheritable genetic damage induced by the two radiations in mature sperm were not significantly different.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.