PubMed HealthSearch

Biomedical subjects

M L Cannon

Publications and source records attributed to M L Cannon.

10 recordsLinked to original sources

Liquid ventilation improves pulmonary function and cardiac output in a neonatal swine model of cardiopulmonary bypass.

OBJECTIVE: Neonatal and infant cardiopulmonary bypass results in multiorgan system dysfunction. Organ protective strategies have traditionally been directed at the myocardium and brain while neglecting the sometimes severe injury to the lungs. We hypothesized that liquid ventilation would improve pulmonary function and cardiac output in neonates after cardiopulmonary bypass. METHODS: Twenty neonatal swine were randomized to receive cardiopulmonary bypass with or without liquid ventilation. In the liquid-ventilated group, a single dose of perflubron was administered before bypass. The control group was conventionally ventilated. Each animal was placed on nonpulsatile, hypothermic bypass. Low-flow cardiopulmonary bypass was performed for 60 minutes. The flow rate was returned to 125 ml/kg per minute, and after warming to 37 degrees C, the animals were removed from bypass. Hemodynamic and ventilatory data were obtained after bypass to assess the effects of liquid ventilation. RESULTS: Without liquid ventilation, cardiopulmonary bypass resulted in a significant decrease in cardiac output, oxygen delivery, and static pulmonary compliance compared with prebypass values. Input pulmonary resistance and characteristic impedance increased in these control animals. At 30, 60, and 90 minutes after bypass, the animals receiving liquid ventilation showed significantly increased cardiac output and static compliance and significantly decreased input pulmonary resistance and characteristic impedance compared with control animals not receiving liquid ventilation. CONCLUSIONS: Liquid ventilation improved pulmonary function after neonatal cardiopulmonary bypass while increasing cardiac output. The morbidity associated with cardiopulmonary bypass may be significantly reduced if the adverse pulmonary sequelae of bypass can be diminished. Liquid ventilation may become an important technique to protect the lungs from the deleterious effects of cardiopulmonary bypass.

Animals

Increasing tidal volumes and pulmonary overdistention adversely affect pulmonary vascular mechanics and cardiac output in a pediatric swine model.

OBJECTIVES: In a pediatric swine model, the effects of increasing tidal volumes and the subsequent development of pulmonary overdistention on cardiopulmonary interactions were studied. The objective was to test the hypothesis that increasing tidal volumes adversely affect pulmonary vascular mechanics and cardiac output. An additional goal was to determine whether the effects of pulmonary overdistention are dependent on delivered tidal volume and/or positive end-expiratory pressure (PEEP, end-expiratory lung volume). DESIGN: Prospective, randomized, controlled laboratory trial. SETTING: University research laboratory. SUBJECTS: Eleven 4- to 6-wk-old swine, weighing 8 to 12 kg. INTERVENTIONS: Piglets with normal lungs were anesthetized, intubated, and paralyzed. After median sternotomy, pressure transducers were placed in the right ventricle, pulmonary artery, and left atrium. An ultrasonic flow probe was placed around the pulmonary artery. MEASUREMENTS AND MAIN RESULTS: The swine were ventilated and data were collected with delivered tidal volumes of 10, 15, 20, and 25 mL/kg and PEEP settings of 5 and 10 cm H2O in a random order. Pulmonary overdistention was defined as a decrease in dynamic compliance of > or =20% when compared with a compliance measured at a baseline tidal volume of 10 mL/kg. At this baseline tidal volume, airway pressure-volume curves did not demonstrate pulmonary overdistention. Tidal volumes and airway pressures were measured by a pneumotachometer and the Pediatric Pulmonary Function Workstation. Inspiratory time (0.75 sec), FIO2 (0.3), and minute ventilation were held constant. We evaluated the pulmonary vascular and cardiac effects of the various tidal volume and PEEP settings by measuring pulmonary vascular resistance, pulmonary characteristic impedance, and cardiac output. When compared with a tidal volume of 10 mL/kg, a tidal volume of 20 mL/kg resulted in a significant decrease in dynamic compliance from 10.5 +/- 0.9 to 8.4 +/- 0.6 mL/cm H2O (p = .02) at a constant PEEP of 5 cm H2O. The decrease in dynamic compliance of 20% indicated the presence of pulmonary overdistention by definition. As the tidal volume was increased from 10 to 20 mL/kg, pulmonary vascular resistance (1351 +/- 94 vs. 2266 +/- 233 dyne x sec/cm5; p = .004) and characteristic impedance (167 +/- 12 vs. 219 +/- 22 dyne x sec/cm5; p = .02) significantly increased, while cardiac output significantly decreased (951 +/- 61 vs. 708 +/- 48 mL/min; p = .001). Each of these effects of pulmonary overdistention were further magnified when the tidal volume was increased to 25 mL/kg. The tidal volume-induced alterations in pulmonary vascular mechanics, characteristic impedance, and cardiac output occurred to a greater degree when the PEEP was increased to 10 cm H2O. Pulmonary vascular resistance and characteristic impedance were significantly increased and cardiac output significantly decreased for all tidal volumes studied at a PEEP of 10 cm H2O as compared with 5 cm H2O. CONCLUSIONS: Increasing tidal volumes, increasing PEEP levels, and the development of pulmonary overdistention had detrimental effects on the cardiovascular system by increasing pulmonary vascular resistance and characteristic impedance while significantly decreasing cardiac output. Delivered tidal volumes of >15 mL/kg should be utilized cautiously. Careful monitoring of respiratory mechanics and cardiac function, especially in neonatal and pediatric patients, is warranted.

Animals

Surface resistance to abrasion of preformed laminate resin veneers.

Preformed laminate resin veneers should be adapted closely to the teeth to reduce the thickness of the composite layer. Minimal voids at the composite, veneer, and tooth junctional margin will result. Composite resins are difficult to finish, but laminate veneer can be highly polished. Poorly finished veneer surfaces appear to abrade to a smoother surface with toothbrushing while poorly finished composite surfaces remain rough. To reduce material loss from abrasion, the veneer restoration should be highly polished. Polishing the veneer at the gingival margin is particularly important to gingival health. Only rough veneer surfaces will be improved by toothbrushing abrasion. Special instructions should be given to patients with laminated veneers to reinforce proper oral hygiene and to discourage use of highly abrasive dentifrices. Continued monitoring of plaque accumulation should minimize problems related to oral hygiene.

Adolescent