PubMed Health⌕ Search

Biomedical subjects

M L Coles

Publications and source records attributed to M L Coles.

2 recordsLinked to original sources

Proposed performance criteria for extended wear contact lenses.

The introduction of silicone-hydrogel materials has changed expectations for the response to contact lenses used in extended wear. In keeping with this technology shift, we have re-evaluated the criteria by which practitioners judge the performance of extended wear lenses. Attendees at the 1999 Annual Clinical Conference of the British Contact Lens Association were surveyed. The proportion of respondents who considered it appropriate to fit selected patients with conventional, disposable and silicone-hydrogel soft lenses for extended wear was 63%, 67% and 86%, respectively. Only 11% of respondents did not fit extended wear because of personal experience with infectious keratitis, and over 50% relied on educators' advice in avoiding this practice. Fifteen per cent of practitioners reported fitting extended wear on occasions. Ninety-five per cent of respondents thought that the relative risk of infectious keratitis with daily wear compared with no lens wear should be ten or less, which was reduced to 60% when it was revealed that the current relative risk is estimated to be 60. A strong preference for a relative risk of infection with extended wear compared to daily wear of less than five times was indicated, which is consistent with current estimates. A minority of respondents were prepared to accept an overnight oedema level of over 6% with extended wear, although silicone-hydrogel materials have been shown to induce less than 4%. A wide variety of microcyst responses were considered reasonable, with many respondents accepting up to 40 per cornea; again, this result contrasted with early research data suggesting a level of 10 microcysts or less occurring with silicone-hydrogel materials. Interpretation of these findings has led us to the following proposals for safe extended wear: (i) extended wear fitting should preferably be done with silicone-hydrogel materials, rather than conventional hydrogels, where the available parameter ranges overlap; (ii) the relative risk of corneal infection with extended wear compared to daily wear should be two to five times, providing the relative risk of daily wear compared to the no lens wear'situation is reduced to 20 times, and (iii) extended wear lenses should produce an average of no more than 4% overnight oedema and no more than 10 microcysts per eye in the long term.

Journal Article↗

Extended wear in perspective.

BACKGROUND: Convenience and safety are major motivating factors in the choice of a mode of correction for refractive errors. Extended wear of contact lenses is associated with greater convenience than daily wear, but questions remain concerning the safety and risks associated with this modality. This paper investigates the hurdles that have rendered extended wear an unfavorable option thus far and seeks to identify strategies to overcome these obstacles. METHOD: We review the history of extended contact lens wear, focusing on soft extended wear for cosmetic use. Results of incidence and relative risk studies for the major complications are scrutinized. The factors that are associated with increased risk together with mechanisms which have been proposed on based on scientific research are analyzed to derive strategies for preventing adverse reactions in extended wear. RESULT: Infectious keratitis associated with extended wear of contact lenses has been identified by the community as a major issue, although the degree of concern may be disproportionate. Current perceptions of the relative risk of extended wear versus daily wear in the context of the risk for nonwearers may be misplaced, and the role of eye closure versus consistency and duration of wear remains open to debate. In the minds of practitioners and patients, other adverse reactions may be of greater significance in rejecting extended wear. Nonetheless, the potential extent of injury from infection demands attention. Studies collectively attest that corneal hypoxia during extended wear is a potential causative mechanism in infectious keratitis, suggesting that the provision of higher oxygen levels to the cornea will reduce morbidity rates from this unwanted complication. However, the issues of stagnation of the post-lens tear film during eye closure, mechanical properties of the lens, and lens movement remain unresolved and may prove to be contributing factors to adverse responses. CONCLUSIONS: Attention to oxygen permeability and mechanical properties of soft contact lenses should solve the remaining problems with extended wear. Materials currently under development promise to meet at least some of the desired properties and may lead to the long-awaited advent of safe extended wear.

Animals↗