PubMed Health⌕ Search

Biomedical subjects

M L Marin

Publications and source records attributed to M L Marin.

At least 55 records · Page 3Linked to original sources

Ex vivo human carotid artery bifurcation stenting: correlation of lesion characteristics with embolic potential.

PURPOSE: To develop an ex vivo human carotid artery stenting model that can be used for the quantitative analysis of risk for embolization associated with balloon angioplasty and stenting and to correlate this risk with lesion characteristics to define lesions suitable for balloon angioplasty and stenting. METHODS: Specimens of carotid plaque (n = 24) were obtained circumferentially intact from patients undergoing standard carotid endarterectomy. Carotid lesions were prospectively characterized on the basis of angiographic and duplex findings before endarterectomy and clinical findings. Specimens were encased in a polytetrafluoroethylene wrap and mounted in a flow chamber that allowed access for endovascular procedures and observations. Balloon angioplasty and stenting were performed under fluoroscopic guidance with either a Palmaz stent or a Wallstent endoprosthesis. Ex vivo angiograms were obtained before and after intervention. Effluent from each specimen was filtered for released embolic particles, which were microscopically examined, counted, and correlated with various plaque characteristics by means of multivariate analysis. RESULTS: Balloon angioplasty and stenting produced embolic particles that consisted of atherosclerotic debris, organized thrombus, and calcified material. The number of embolic particles detected after balloon angioplasty and stenting was not related to preoperative symptoms, sex, plaque ulceration or calcification, or artery size. However, echolucent plaques generated a higher number of particles compared with echogenic plaques (p < 0.01). In addition, increased lesion stenosis also significantly correlated with the total number of particles produced by balloon angioplasty and stenting (r = 0.55). Multivariate analysis revealed that these two characteristics were independent risk factors. CONCLUSIONS: Echolucent plaques and plaques with stenosis > or = 90% produced a higher number of embolic particles and therefore may be less suitable for balloon angioplasty and stenting. This ex vivo model can be used to identify high-risk lesions for balloon angioplasty and stenting and can aid in the evaluation of new devices being considered for carotid balloon angioplasty and stenting.

Angioplasty, Balloon↗

Aortoiliac aneurysms: endoluminal repair--clinical evidence for a fully supported stent-graft.

PURPOSE: To evaluate aortoiliac aneurysms repaired with endovascular stent-grafts complicated by hemodynamically significant graft stenosis. MATERIALS AND METHODS: Fifty-four patients (52 men, two women; age range, 41-90 years; mean age, 75 years) with aneurysms of the infrarenal aorta (n = 36) or iliac artery (n = 18) underwent repair by means of placement of an endovascular stent-graft. Technical success was evaluated angiographically during and after placement. At follow-up (range, 12-44 months), all patients underwent sequential duplex ultrasonography, helical computed tomography, and physical examination. RESULTS: Stent-grafts were placed successfully in all cases. Stenosis at the internal iliac arterial origin was identified at angiography in 17 patients (31%). Supplemental intragraft stents were placed in 11 patients, and stent-graft angioplasty alone was performed in one patient. Intragraft stents were placed percutaneously in five patients when stenosis was discovered during follow-up. CONCLUSION: Supplemental intragraft stents were required in 31% of aortoiliac endovascular stent-grafts to correct stent-graft stenosis and preserve long-term function. Placement of a fully supported stent-graft is necessary to repair an aortoiliac aneurysm.

Adult↗

The effect of nonporous PTFE-covered stents on intimal hyperplasia following balloon arterial injury in minipigs.

PURPOSE: To report an experimental study investigating the ability of nonporous polytetrafluoroethylene (PTFE) covering on a metallic stent to retard the development of neointimal hyperplasia (NIH). METHODS: Three groups of Hanford miniature swine underwent standardized balloon injury to both external iliac arteries. Group I animals (control) received balloon injuries only. Group II had the site of balloon injury supported by a properly sized, balloon-expandable Palmaz stent placed directly over the injury site. Group III animals received a Palmaz stent covered with PTFE graft. All animals underwent arteriography immediately after intervention and again prior to sacrifice and specimen harvest at 4 weeks. The specimens were examined grossly and histologically at the proximal, middle, and distal segments for NIH development. RESULTS: Uncovered stents developed significantly more NIH (p < 0.0001) and greater luminal narrowing (p < 0.001) than the controls. PTFE-covered stents (group III) exhibited less NIH (p < 0.001) and luminal reduction (p < 0.01) than bare stents (group II) at the middle portion of the stent-graft, but the PTFE cover had no effect on NIH and lumen reduction at the proximal or distal ends of the prosthesis. CONCLUSIONS: PTFE-covered stents retarded NIH at 4 weeks, but only at the midportion of the devices; the covering did not prevent neointimal pannus ingrowth at the proximal and distal ends.

Angiography↗

Value of CT angiography for postoperative assessment of patients with iliac artery aneurysms who have received endovascular grafts.

OBJECTIVE: The purpose of the study was to assess the usefulness of CT angiography for follow-up of patients with iliac artery aneurysms who have undergone endovascular treatment. SUBJECTS AND METHODS: Twelve patients with iliac artery aneurysms (10 true aneurysms and two pseudoaneurysms) were examined with CT angiography within 1 week of receiving transfemorally placed endovascular grafts. All patients underwent follow-up CT angiography from 3 to 30 months (mean, 11 months) later. Follow-up CT angiography at 6 months or later (mean, 14 months) was also available in 10 patients. All studies were obtained after i.v. contrast administration using 3-mm collimation, 1.6-2.0 pitch, 2-mm retrospective reconstruction, and with subsequent three-dimensional rendering and multiplanar reformation. The shape and patency of the graft, perigraft thrombosis, and the size of the aneurysm were assessed. RESULTS: All grafts remained patent and without deformity. Complete thrombosis of the aneurysm was shown by initial postoperative CT angiography in 11 patients and confirmed by follow-up studies. A single case of a perigraft leak was revealed by CT angiography and confirmed by follow-up angiography. No aneurysm showed change in size at late follow-up. CONCLUSION: CT angiography is an accurate method for evaluating endovascular devices. CT angiography can be used as a primary technique for follow-up of patients who have undergone endovascular repair of iliac aneurysms.

Aged↗

Stimulation of cytokine production in clonal macrophage and T-cell models by Streptococcus thermophilus: comparison with Bifidobacterium sp. and Lactobacillus bulgaricus.

The effects of four commercial strains of Streptococcus thermophilus used in yogurt manufacturing on cytokine production were evaluated by using a macrophage model (RAW 264.7 cells) and a T-helper-cell model (EL4.IL-2 thymoma cells) and compared to immunologically active strains of Lactobacillus bulgaricus, Bifidobacterium adolescentis, and Bifidobacterium bifidum. All cytokines (TNF-alpha and IL-6 in RAW 264.7 cells and IL-2 and IL-5 in EL4.IL-2 cells) were affected by heat-killed S. thermophilus in a strain- and dose-dependent fashion. Organisms of all three genera induced significant increases in IL-6 production by the macrophage line ranging from 31- to 192-fold, with S. thermophilus St 133 showing the greatest activity. The four S. thermophilus strains also strongly induced TNF-alpha production (from 135- to 176-fold). IL-6 and, to a lesser extent, TNF-alpha production were also increased when the macrophages were costimulated with lipopolysaccharide and cells of the three groups of lactic acid bacteria. Upon concurrent stimulation of EL4.IL-2 cells with phorbol 12-myristate-13-acetate, seven of the eight strains displayed significant enhancement of IL-2 and IL-5 production, with S. thermophilus being most effective. Taken together, the S. thermophilus strains stimulated macrophage and T-cell cytokine production to a similar or greater extent than did the species of Bifidobacterium and Lactobacillus. These and previous results lend further support to the contention that lactic acid bacteria, in a concentration-dependent manner, can differentially induce cytokine production in macrophages, but that the effects on T cells required a costimulatory signal and were less remarkable.

Animals↗

Anastomotic intimal hyperplasia: a comparison between conventional and endovascular stent graft techniques.

Endovascular grafts (EVGs) have been proposed as a treatment for a variety of vascular diseases; however, the impact of EVGs on graft healing has not been fully evaluated. The aim of this study is to compare anastomotic intimal hyperplasia (AIH) and endothelialization in EVGs and conventional bypass grafts (CGs). Seven mongrel dogs received an EVG in one iliac artery and a CG in the other iliac artery using a 5 mm x 4 cm polytetrafluoroethylene graft. The EVG was secured to the native vessel wall, with balloon expandable stents at either ends of the graft. CGs were anastomosed using running sutures. Intravascular ultrasound was performed at the time of sacrifice (8 weeks) to determine percentage of stenosis at the distal anastomosis. Specimens were divided longitudinally for light microscopic analysis (thickness of distal AIH) and scanning electron microscopic studies (percentage of endothelial coverage of the graft). Percentage of stenosis at the distal anastomosis was significantly higher in EVGs compared with CGs (28.2 +/- 18.2% versus 1.8 +/- 2.8%; P < 0.01) due to significantly greater mean intimal thickness in the EVGs (441.1 +/- 101.1 microns versus 82.4 +/- 41.9 microns; P < 0.01). The total percentage of area covered by endothelial cells was also significantly greater in EVGs compared with CGs (80.5 +/- 37.5% versus 30.3 +/- 37.1%; P < 0.05). Intraluminal location enhanced endothelialization of the polytetrafluoroethylene graft; however, it also resulted in greater AIH. Further device refinements including stent design may be required to maximize the potential of these endovascular procedures.

Anastomosis, Surgical↗

Endovascular grafts for noninfected aortoiliac anastomotic aneurysms.

PURPOSE: This report describes our experience with endovascular repair of aortic and iliac anastomotic aneurysms. METHODS: Between June 1994 and March 1996, 12 noninfected aortic or iliac anastomotic aneurysms in 10 patients who had serious comorbid medical conditions that precluded or made difficult standard operative repair were treated using endovascular grafts. No patient in this study had a history of fever, leukocytosis, or computed tomographic evidence of a periprosthetic fluid collection that was suggestive of infection of the original graft. Endovascular grafts composed of polytetrafluoroethylene and balloon-expandable stents were introduced through a femoral arteriotomy and were placed using over-the-wire techniques under C-arm fluoroscopic guidance. RESULTS: Endovascular grafts were successfully inserted in all patients with aortic or iliac anastomotic aneurysms. There were no procedure-related deaths, and complications included one postprocedure wound hematoma and one perioperative myocardial infarction. Graft patency has been maintained for a mean of 16.1 months, with no computed tomographic evidence of aneurysmal enlargement or perigraft leakage. CONCLUSIONS: Endovascular grafts appear to be a safe and effective technique for excluding some noninfected aortoiliac anastomotic aneurysms in high-risk patients and may become a treatment option in all patients who have clinically significant lesions.

Aged↗

Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion.

PURPOSE: To evaluate and compare the intraaneurysmal pressure (IAP) after exclusion using two different endovascular grafts. METHODS: Eight mongrel dogs had a 3 x 3 cm polytetrafluoroethylene (PTFE) aneurysm sewn as an interposition graft of the infrarenal aorta. A pressure transducer implanted into the aneurysm wall permitted continuous electronic IAP monitoring. Four aneurysms were excluded with a transluminally placed endovascular graft made of a PTFE graft and two Palmaz stents (PTFE-EG), three were excluded with a tantalum-Dacron endovascular graft (TD-EG), and one was surgically treated with a standard PTFE graft (PTFE-Surg). The dogs were observed for 18 to 50 days (mean, 37.5 days) and were evaluated after surgery with duplex and spiral computed tomographic scans. RESULTS: All grafts successfully excluded the aneurysms without perigraft channels or leaks as documented by arteriogram and duplex and computed tomographic scans. The mean IAPs after repair with all PTFE-EGs were significantly lower (p < 0.001) than the mean systemic pressures. In addition, the mean IAP reduction was significantly greater (p < 0.005) in the PTFE-EG group than in the TD-EG group. CONCLUSIONS: Aneurysm exclusion with PTFE-EG significantly lowered IAP, did so significantly better than the TD-EG, and approached the IAP reduction obtained by standard repair. Such pressure reduction is necessary for effective protection against aneurysm rupture.

Animals↗

Evaluation of endovascular abdominal aortic aneurysm repair: anatomical classification, procedural success, clinical assessment, and data collection.

PURPOSE: To detail a methodology for evaluation of endovascular abdominal aortic aneurysm (AAA) repair that has been achieved through consensus of an international multidisciplinary team of investigators. METHODS: This schema features an anatomical classification for AAAs, a definition of procedural success, and a procedure for clinical assessment, as well as the necessary data collection forms. Patient data include demographics, procedural and clinical success, complications, and follow-up. Procedural details can be related to anatomic situations, comorbid processes, devices, and effective aneurysmal exclusion. RESULTS: These data would allow assessment of the procedures, physician learning curves, procedural indications, techniques, methodologies, the relationship of indications to success and complications, devices and subsequent graft patency, and aneurysmal exclusion. CONCLUSIONS: The use of this standardized data collection system could enable physicians and industry to better understand endovascular AAA repair and ultimately improve patient care.

Aortic Aneurysm, Abdominal↗

An experimental model for the acute and chronic evaluation of intra-aneurysmal pressure.

PURPOSE: To develop an animal model for the acute and chronic monitoring of pressure within abdominal aortic aneurysms (AAAs) to be treated with endovascular grafts. METHODS: A strain-gauge pressure transducer was placed within an AAA created from a prosthetic vascular graft. Prosthetic aneurysms were implanted into 17 canine infrarenal aortas. The intra-aneurysmal pressure was monitored and correlated with noninvasive forelimb sphygmomanometry for 2 weeks. After this time, an intravascular manometer catheter was passed into the aneurysm. Simultaneous pressure measurements were obtained using the implanted strain-gauge pressure transducer, the manometer catheter, and the forelimb sphygmomanometer. Angiography was performed to assess intraluminal morphology, aneurysm anastomoses, and adjoining aortic vessels. In addition, two control animals underwent intra-aneurysmal pressure monitoring after standard surgical aneurysm repair. RESULTS: There was excellent correlation (r = 0.97) between the pressure measurements obtained with the implanted strain-gauge pressure transducer and the intravascular manometer. Close correlation was also observed between the implanted strain-gauge transducer and the forelimb sphygmomanometer (r = 0.88) during postprocedural monitoring. Intra-aneurysmal pressure was lowered dramatically by surgical exclusion (aneurysm: 15/5 +/- 7/4 mmHg; systemic: 124/66 +/- 34/17 mmHg; p < 0.001). The prosthetic aneurysms were successfully imaged with angiography. CONCLUSIONS: This animal model provides an accurate and reproducible means for measuring intra-aneurysmal pressure on an acute and chronic basis. It may be possible to use this model in the assessment of endovascular devices to determine their efficacy in reducing intra-aneurysmal pressure. Evaluation of complications associated with their use, such as patent aneurysm side branches, perigraft channels, and perianastomotic reflux, may also be possible.

Animals↗

Differential cytokine production in clonal macrophage and T-cell lines cultured with bifidobacteria.

When used in commercial fermented dairy products, bifidobacteria may enhance immunity by stimulating cytokine secretion by leukocytes. To assess whether interaction between bifidobacteria and leukocytes promote cytokine production, we cultured RAW 264.7 cells (macrophage model) and EL-4.IL-2 thymoma cells (helper T-cell model) in the presence of 14 representative strains of heat-killed bifidobacteria. In unstimulated RAW 264.7 cells, all bifidobacteria induced pronounced increases (up to several hundred-fold) in the production of tumor necrosis factor-alpha compared with that of controls. Interleukin-6 production by unstimulated cells also increased significantly, but less than did tumor necrosis factor-alpha. Upon concurrent stimulation of RAW 264.7 cells with lipopolysaccharide, production of tumor necrosis factor-alpha and interleukin-6 were both enhanced between 1.5- to 5.8-fold and 4.7- to 7.9-fold, respectively, when cultured with 10(8) bifidobacteria/ml. In unstimulated EL-4.IL-2 cells, bifidobacteria had no effect on the production of interleukin-2 or interleukin-5. Upon stimulation of EL-4.IL-2 with phorbol-12-myristate-13-acetate, there were variable increases in interleukin-2 secretion (up to 2.4-fold for 10(6) Bifidobacterium Bf-1/ml) and interleukin-5 secretion (up to 4.6-fold for 10(8) B. adolescentis M101-4). The results indicated that, even when variations among strains were considered, direct interaction of most bifidobacteria with macrophages enhanced cytokine production, but the effects on cytokine production by the T-cell model were less marked. Interestingly, the 4 bifidobacteria strains used commercially for diary foods showed the greatest capacity for cytokine stimulation. The in vitro approaches employed here should be useful in future characterization of the effects of bifidobacteria on gastrointestinal and systemic immunity.

Animals↗

Endovascular surgery: threat or opportunity?

Although the fundamentals of Endovascular Surgery were set down over 30 years ago, only recently has the potential impact of this therapy become readily apparent. Endovascular therapies with new instrumentation for the treatment of arterial aneurysms, occlusions, trauma, and venous thrombotic disorders have progressed dramatically over the past 5 years. Guidewire and catheter techniques for endovascular instrumentation of vessels have also been shown to compliment standard vascular surgical interventions. The need for vascular surgeons to obtain the knowledge and professional skills to perform wire and catheter techniques is essential to convert the professional "threat" of endovascular surgery to a future of "opportunity."

Aneurysm↗

Varying strategies and devices for endovascular repair of abdominal aortic aneurysms.

The endovascular repair of abdominal aortic aneurysms has been investigated in a clinical setting since 1991. Although initially the procedure was performed using surgeon-made devices, it did not take long for the medical industry to realize the potential of this procedure. There are six commercially made devices, which are unique, each with their own strengths and weaknesses. This article describes the principal endovascular graft types that are currently under investigation as well as the strategies for their use. In addition, the inclusion criteria for endovascular repair of abdominal aortic aneurysms are discussed.

Aortic Aneurysm, Abdominal↗

Endovascular approaches for traumatic arterial lesions.

Vascular injuries caused by blunt or penetrating trauma can be challenging to diagnose and treat, particularly when they involve central vessels. Endovascular treatment for vascular trauma includes the placement of embolization coils and intravascular stents and the employment of stented grafts. The use of stented grafts appears to be associated with decreased blood loss, a less invasive insertion procedure, reduced requirements for anesthesia, and a limited need for an extensive dissection in a traumatized field. These advantages are especially important in patients with central arteriovenous fistulas or false aneurysms, particularly those who are critically ill from other coexisting injuries or medical comorbidities. In these circumstances, the use of stented grafts already appears justified to treat traumatic central arterial lesions. Endovascular grafts are important tools for the treatment of vascular trauma, and they should be included in the armamentarium of the vascular surgeon.

Angiography↗