Cascade analysis for medical imaging detectors with stages involving both amplification and dislocation processes.

Cascade analysis is a powerful tool which can be used to calculate the signal and noise properties of medical imaging detectors. It involves the conceptual separation of the imaging chain into stages which consist of either pure amplification or pure dislocation stages. It is, however, not always possible to break the physical processes down to these elementary stages. In this work we derive a new cascade equation which is applicable to any stage which involves multiple amplifications and dislocations. The equation simplifies to the known equations for pure amplification and pure dislocation stages in the appropriate limits, and can be numerically calculated using Monte Carlo techniques for more complicated situations. We demonstrate the use of this equation with an example: we derive an expression for the DQE of a metal/phosphor detector for megavoltage imaging with our formalism, and evaluate the expression with Monte Carlo techniques. We have found that there is excellent agreement between theory and experimental results, and believe that the formalism could be useful for other applications where the amplification and dislocation processes cannot be divided into elementary stages.

Diagnostic Imaging↗

Detective quantum efficiency of a direct-detection active matrix flat panel imager at megavoltage energies.

The use of an amorphous selenium (a-Se) based direct-detection active matrix flat-panel imager (AMFPI) is studied for megavoltage imaging. The detector consists of a 1.2 mm copper front plate and 200 microm a-Se layer, and has a 85 microm pixel pitch. The Modulation Transfer Function (MTF), Noise Power Spectrum (NPS), and Detective Quantum Efficiency (DQE) are measured for 6 and 15 MV photon beams. A theoretical expression for the DQE is derived using a recently developed formalism for nonelementary cascade stages. A comparison of theory with experiment is good for the 6 and 15 MV beams. The model is used to explore the DQE for more typical pixel sizes. The results indicate that with proper modifications, such as a larger a-Se thickness, a direct flat-panel AMFPI is a very promising detector for megavoltage imaging.

Electrons↗

Investigation into the physical characteristics of active matrix flat panel imagers for radiotherapy.

The effect of physical characteristics on active matrix flat panel imagers (AMFPIs) at megavoltage energies is studied. The detective quantum efficiency (DQE) of both direct and indirect AMFPIs is modeled using a modified cascade analysis combined with Monte Carlo simulations. It is found that for a given thickness of the sensitive layer less than about 1 mm, there should be no significant difference between the detection techniques, but for larger mass thicknesses (> or = 1 mm) there should be an advantage to using direct detection if such thick layers can be manufactured. The effect of the front plate on both direct and indirect techniques is also explored in terms of both the DQE and scatter rejection. It is found that for small sensitive layer thicknesses (< or =0.3 mm) a front plate thickness of about 1 mm Cu is optimal, whereas for larger mass thicknesses about 0.4 mm Cu should lead to better image quality.

Computer Simulation↗

Setup verification in linac-based radiosurgery.

A semi-automatic technique for the direct setup alignment of radiosurgical circular fields from an isocentric linac to treatment room laser cross-hairs is described. Alignment is achieved by acquiring images of the treatment room positioning laser cross-hairs superimposed on the radiosurgical circular field image. An alignment algorithm calculates the center of the radiosurgical field image as well as the intersection of the laser cross-hairs. This determines any alignment deviations and the information is then used to translate the radiosurgical collimator to its correct aligned position. Two detectors, each being sensitive to the lasers and ionizing radiation, were used to acquire the radiation/laser images. The first detector consists of a 0.3-mm-thick layer of photoconducting a-Se deposited on a 1.5-mm-thick copper plate and the second is film. The algorithm and detector system can detect deviations with a precision of approximately 0.04 mm. A device with gyroscopic degrees of freedom was built in order to firmly hold the detector at any orientation perpendicular to the radiosurgical beam axis. This device was used in conjunction with our alignment algorithm to quantify the isocentric sphere relative to the treatment room lasers over all gantry and couch angles used in dynamic stereotactic radiosurgery.