In vitro evaluation of Haemonetics MCS+ apheresis platelet concentrates treated with photochemical pathogen inactivation following plasma volume reduction using the INTERCEPT Preparation Set.

Pathogen inactivation using the INTERCEPT Blood System requires platelet resuspension in InterSol and reduced plasma. Platelets in plasma collected on the Haemonetics MCS+ were processed on the INTERCEPT Preparation Set for plasma volume reduction and addition of InterSol. The use of the Preparation Set resulted in a mean platelet loss of 5.6 +/- 3.4%. Subsequent photochemical treatment (PCT) with amotosalen and ultraviolet A light, and 7 days of storage, resulted in acceptable changes for platelet swirling, lactate, lactate dehydrogenase (LDH), platelet factor-4 (PF4), p-selectin, glycoprotein V (GpV), pO2, pCO2, tumour necrosis factor-alpha (TNF-alpha) and interleukin-8 (IL-8). All platelet units processed with the Preparation Set and PCT met European requirements for leucoreduction and pH values.

Blood Platelets↗

Leukodepletion of platelet concentrates and plasma collected with haemonetics MCS+ apheresis system. Experience of EFS-Alsace.

The prevention of transfusion reactions and transmission of infectious diseases partly relies on the systematic removal of leukocytes from blood products. Apheresis platelets and plasma collected on the Haemonetics MCS+ collection system require filtration to obtain low levels of residual leukocytes. This filtration step is automated for platelet concentrates, whereas plasma filtration requires sterile docking of a leukoreduction filter. Our experience shows residual leukocyte levels of approximately 10(5) for platelets (the French requirements are 10(6) per unit) and 10(2) for apheresis plasma (no existing standard in France). Leukocyte residuals in platelets are highly dependent on the filtration rate, which should be as slow as possible. Whereas the current method of filtration is convenient for platelets, the connection of an in-line filter for plasma causes some organizational problems and is also associated with a loss of plasma. Haemonetics' latest development, the use of a filtering core bowl, should avoid the requirement for the connection of an additional filter for plasma filtration and will ensure continuous filtration of platelets, reducing, even further, the residual leukocyte count in platelet concentrates.

Blood Platelets↗