PubMed Health⌕ Search

Biomedical subjects

M Langhans

Publications and source records attributed to M Langhans.

10 recordsLinked to original sources

Role of cytokinin and auxin in shaping root architecture: regulating vascular differentiation, lateral root initiation, root apical dominance and root gravitropism.

BACKGROUND AND AIMS: Development and architecture of plant roots are regulated by phytohormones. Cytokinin (CK), synthesized in the root cap, promotes cytokinesis, vascular cambium sensitivity, vascular differentiation and root apical dominance. Auxin (indole-3-acetic acid, IAA), produced in young shoot organs, promotes root development and induces vascular differentiation. Both IAA and CK regulate root gravitropism. The aims of this study were to analyse the hormonal mechanisms that induce the root's primary vascular system, explain how differentiating-protoxylem vessels promote lateral root initiation, propose the concept of CK-dependent root apical dominance, and visualize the CK and IAA regulation of root gravitropiosm. KEY ISSUES: The hormonal analysis and proposed mechanisms yield new insights and extend previous concepts: how the radial pattern of the root protoxylem vs. protophloem strands is induced by alternating polar streams of high IAA vs. low IAA concentrations, respectively; how differentiating-protoxylem vessel elements stimulate lateral root initiation by auxin-ethylene-auxin signalling; and how root apical dominance is regulated by the root-cap-synthesized CK, which gives priority to the primary root in competition with its own lateral roots. CONCLUSIONS: CK and IAA are key hormones that regulate root development, its vascular differentiation and root gravitropism; these two hormones, together with ethylene, regulate lateral root initiation.

Cytokinins↗

Immunolocalization of plasma-membrane H+-ATPase and tonoplast-type pyrophosphatase in the plasma membrane of the sieve element-companion cell complex in the stem of Ricinus communis L.

Plasma-membrane-located primary pumps were investigated in the sieve element (SE)-companion cell complex in the transport phloem of 2-week-old stems of Ricinus communis L. and, for comparison, in stems of Cucurbita pepo L. and in the secondary phloem of Agrobacterium tumefaciens-induced crown galls as a typical sink tissue. The plasma-membrane (PM) H+-ATPase and the tonoplast-type pyrophosphatase (PPase) were immunolocalized by epifluorescence and confocal laser scanning microscopy (CLSM) upon single or double labeling with specific monoclonal and polyclonal antibodies. Quantitative fluorescence evaluation by CLSM revealed both pumps in one membrane, the sieve-element PM. Different PM H+-ATPase antibody clones, raised against the PM H+-ATPase of Zea mays coleoptiles, induced in mouse and produced in mouse hybridoma cells, discriminated between different phloem cell types. Clones 30D5C4 and 44B8A1 labeled sieve elements and clone 46E5B11D5 labeled companion cells, indicating the existence of different phloem PM H+-ATPase isoforms. The results are discussed in terms of energization of SE transporters for retrieval of leaking sucrose, K+ and amino acids, as one of the unknown roles of ATP found in SEs. The function of the PPase could be related to phloem sucrose metabolism in support of ATP-requiring processes.

Antibodies, Monoclonal↗

Effect of breathing 100% oxygen on retinal and optic nerve head capillary blood flow in smokers and non-smokers.

AIM: The effect of breathing 100% oxygen on retinal and optic nerve head capillary blood flow in smokers and non-smokers was investigated using scanning laser Doppler flowmetry (SLDF) as a new non-invasive method to visualise and quantify ocular blood flow. METHOD: 10 eyes of 10 young healthy non-smoking volunteers (mean age 26 (SD 3) years) and nine eyes of nine young healthy smoking volunteers (mean age 26 (4) years) were investigated. All participants were asked not to smoke or consume caffeine containing drinks for at least 4 hours before the measurements. Blood flow measurements were performed before and after 100% oxygen was applied to the subjects through a mask over a period of 5 minutes (6 litres per minute). Juxtapapillary retinal and optic nerve head blood flow were determined in arbitrary units using SLDF representing a combination of laser Doppler flowmetry and a scanning laser system allowing visualisation and quantification of the retinal and optic nerve head blood flow. Blood flow was determined in an area of 100 microns x 100 microns. The level of carboxyhaemoglobin was determined in all subjects. A Wilcoxon matched pairs signed ranks test (non-parametric) was used for statistical evaluation. RESULTS: In the non-smoking group, retinal 'flow' was reduced by 33% (p = 0.005), optic nerve head 'flow' by 37% (p = 0.005). In the smoking group retinal flow was reduced by 10% (p = 0.01), optic nerve head flow by 13% (p < 0.008). The difference in reactivity to oxygen breathing between smokers and non-smokers was highly significant (p < 0.00001). Increased carboxyhaemoglobin levels were not found in either of the groups. A significant reduction of the mean arterial blood pressure of 6% (5%) (p < 0.02) was observed in the non-smoking group after administration of oxygen. CONCLUSION: These results indicate that hyperoxia leads to a decrease in capillary blood flow of the retina and optic nerve head secondary to vasoconstriction, and that smokers do not respond to oxygen breathing as non-smokers do. The findings might be based on factors such as long term effects of nicotine on the sympathetic and parasympathetic nervous system.

Adult↗

[Unnecessary admission from the surgical social medicine viewpoint].

Wrongfully inpatient admission means unnecessary treatment of patients with the means of a hospital. In a study of the Medical Service (MDK) in the German state of Hessen 58% of 954 inpatients were considered wrongfully admitted. 199 patients were treated surgically, the wrongful admission rate of 63% is caused by an unnecessary duration of pre- and postoperative treatment time as well as by organizational deficits.

Aged↗

Perfusion of the juxtapapillary retina and optic nerve head in acute ocular hypertension.

Chronically elevated intraocular pressure (IOP) is often associated with glaucomatous optic nerve atrophy. Impaired blood flow may play a role in the pathogenesis of this disease. We present data concerning juxtapapillary retinal and optic nerve-head blood flow during acute increases in IOP. With the combination of a laser Doppler flowmeter and a scanning-laser system (Scanning Laser Doppler Flowmeter, SLDF; Heidelberg Engineering) the perfusion of the retina and the optic nerve head was quantified and visualized. Juxtapapillary retinal and optic nerve-head blood flow was measured simultaneously by SLDF during variations in IOP induced by a suction cup in nine healthy volunteers. The ocular pressure was increased for 2 min to IOP +15 mmHg, then to IOP +30 mmHg, and finally, to IOP +45 mmHg. Ocular perfusion pressure (PP) was calculated as the mean arterial blood pressure minus the IOP. The declines in juxtapapillary retinal flow as expressed in present per 10-mmHg IOP elevation ranged from 3.6% to 14.1% (median 7.4%). Over all measurements we found a significant linear relationship between juxtapapillary retinal blood flow and PP (r = 0.55, P < 0.0001). The observed decrease in optic nerve-head blood flow with increasing IOP was significantly greater as compared with the retinal blood flow decrease (8.4%/10 mmHg versus 7.4%/10 mmHg, P < 0.05). SLDF enables the quantification and visualization of perfused capillaries of the retina and the optic nerve head in high resolution. Acute elevations of IOP led to a decreases in juxtapapillary retinal and optic nerve-head blood flow of 7.4% and 8.4%/ 10-mmHg IOP increase, respectively.

Acute Disease↗

[2-dimensional mapping and retinal and papillary microcirculation using scanning laser Doppler flowmetry].

PURPOSE: To present clinical applications of a new non-invasive method imaging in a high-definition the topography of perfused retinal vessels. METHOD: By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualized and quantified. The principles of measuring blood flow by Laser Doppler Flowmetry are based on the optical Doppler effect: laser light scattered by a moving particle is shifted in frequency by an amount delta f. Our data acquisition and evaluation system is a modified laser scanning tomograph. The technical data are: retinal area of measurement 2.7 mm x 0.7 mm, 10 degree-field with 256 points x 64 lines, measurement accuracy 10 microns, wavelength 670 nm and 790 nm, light power 100 microW, data acquisition time 2,048 s. Every line is scanned 128 times by a line-sampling rate of 4,000 Hz. By performing a discrete Fast Fourier Transformation over 128 intensities of each retinal point the laser Doppler-shift is calculated for each retinal point. With these data a 2-D map with 256 x 64 points of the retinal perfusion is created. The brightness of the picture-point is coded by the value of the Doppler shift. We estimated the reliability and the validity of the method. Perfusion-pictures of the superficial retinal layer and in the optic nerve head were presented. RESULTS: The reliability-coefficients r1 of "Flow", "Volume" and "Velocity" were 0.85, 0.83, and 0.85 respectively. The blood flow measurements by the presented method ("Scanning Laser Doppler Flowmetry") in an artificial capillary gave a linear relationship (r-value 0.973, p < 0.00001) between defined blood velocities and the measured blood flow. By the confocal technique, dependent on the focus, capillaries of the retinal superficial vasculature of the optic nerve head became visible with a high resolution. Off line the blood flow of areas of 110 microns x 110 microns were calculated in terms of laser Doppler flowmetry. CONCLUSION: "Scanning Laser Doppler Flowmetry" facilitates the visualisation of perfused retinal capillaries and vessels in high resolution. The representation of the function of the retinal circulation by SLDF leads to an image similar to the anatomical situation. The 2-dimensional mapping of local blood flow leads to a physiological picture of the retinal perfusion with visible vessels and capillaries.

Adult↗

[Effect of form elasticity of the prosthesis shaft in response to stress of the proximal femur].

Uncemented hip prostheses are characterized by a variable design of the stem. In these investigations, nine different prostheses were studied according to the model of a standard bone (Kunststoffnormfemur). After preparation of the cavity of the prostheses with original instruments and after its implantation, strain gauges were placed at 16 certain points. Measurements were carried out in steps of 200 N until reaching the maximal force of 2kN. Prostheses that are characterized by an anatomical design of the stem resemble the physiological nature of normal bone, in contrast to the models with a rectangular cross-section or with a stretched lateral shape of the stem.

Biomechanical Phenomena↗