PubMed Health⌕ Search

Biomedical subjects

M Leroux

Publications and source records attributed to M Leroux.

At least 55 records · Page 3Linked to original sources

Airway response to inhaled methacholine in healthy nonsmoking twins.

The variability of maximum expiratory flows is genetically determined, and the airway response to chronic cigarette smoking is also influenced by genetic factors. In nonsmoking nonatopic healthy individuals there is a wide variability of acute airway responses to bronchoactive drugs. The present study was designed to investigate whether this variability might also be genetically determined. We tested this hypothesis by measuring the threshold of airway response to inhaled methacholine using a partial flow-volume curve as the index of response in 10 monozygotic (MZ) and 10 dizygotic (DZ) healthy nonsmoking pairs of twins. Methacholine aerosol was given in doubling doses from number 1 (0.031 mg/ml) to number 11 (32 mg/ml). The mean threshold (+/-SD) for the MZ twins was dose 4.5 +/- 2.4 and for the DZ twins was 7.2 +/- 2.0 (P = 0.0004). No explanation could be found for the difference in mean threshold between MZ and DZ twins. The mean intrapair difference in threshold (+/-SD) for the MZ twins was 2.7 +/- 1.6 doubling doses and for the DZ twins was 2.4 +/- 1.8 (P = 0.7). Slope of dose response to methacholine and intrapair differences were not different between MZ and DZ twins. The present study supports the view that environmental factors are more important than genetic factors in determining the variability of acute airway responsiveness to bronchoactive drugs in healthy nonsmoking individuals.

Adolescent↗

Pharmacokinetic study of valproic acid in a neonate.

Valproic acid was administered to a neonate (gestational age of 39 weeks) at 24 days post partum in an initial single dose of 7.5 mg/kg. Multiple serum samples were collected for 24 hours post dose. Valproic acid was continued and the study was repeated in the same child at 6 months of age at which time the dose had been increased to 13.5 mg/kg (27 mg/kg/day). Serum samples were collected for 12 hours post dose in this second study. A one-compartment model was assumed for calculation of the relevant pharmacokinetic parameters. The half-life (t 1/2) at 24 days of age was 17.2 hours, clearance (Cl) 0.18 ml/min/kg, and volume of distribution (Vd) 0.28 liter/kg. This t 1/2 was less than reported values in neonates younger than 10 days but longer than the average t 1/2 in adults. At 6 months of age, clearance had increased to 0.53 ml/min/kg, t 1/2 had decreased to 7.5 hours, while Vd was relatively unchanged (0.34 liter/kg). Factors possibly causing these changes include hepatic enzyme maturation and concomitant administration of anticonvulsant drugs.

Age Factors↗

Comparison of gas-liquid chromatography and EMIT assay for serum valproic acid.

We describe a simple direct extraction method for the gas-liquid chromatography determination of serum valproic acid. The working range for the assay is 2-180 mg/L and our within-run precision was 5.8 and 4.3% at the 40 and 90 mg/L concentrations respectively. Hemolyzed and lipemic sera as well as samples from patients with hyperbilirubinemia and from patients with decreased renal function were put through the assay and no interfering peaks were noted. Interference occurred when teflon-lined screw caps were used during the extraction step. The method was proven to be accurate by linear regression analysis of samples containing weighed-in amounts of valproic acid. The above assay was compared to an enzyme immunoassay technique (EMIT). The working range for the latter is 10-150 mg/L and the with-run precision was 10.8 and 5.9% and 90 mg/L concentration respectively. Samples were run by both the gas-liquid chromatograph and enzyme immunoassay methods and gave very similar results over the range 16-139 mg/L.

Bilirubin↗

Decrease in lung recoil pressure after cessation of smoking.

Tests of lung mechanics and single-breath carbon monoxide diffusing capacity (DLCO) were done in 26 apparently healthy cigarette smokers before and 2 months after cessation of smoking. There was a significant increase in vital capacity and 1-sec forced expiratory volume as well as improvement in frequency dependence of lung dynamic compliance. Slope and phase III and density dependence of maximal expiratory flow showed a borderline improvement DLCO did not change. Static lung pressure-volume curves showed a small but significant (P less than 0.01) shift toward lower pressures. We concluded that the previously reported decrease in lung recoil pressure observed in smokers is even more accentuated after cessation of smoking.

Adult↗

Measurement of creatine kinase Z in human sera using a DEAE-cellulose mini-column method.

A DEAE-cellulose mini-column method has been developed which allows for the quantitation in human serum of creatine kinase Z, a sub-band of creatine kinase first described by Lim ((1975) Clin. Chem. 21, 975, Abstract 181) and Sax et al. (Sax, S.M., Moore, J.J., Giegel, J.L. and Welsh, M. (1976) Clin. Chem. 22, 87). We have shown that creatine kinase Z is rather unstable in nature, and converts to a form which electrophoreses with creatine kinase MM on agarose gel electrophoresis. CK-Z is not present in normal human serum. CK-Z is present in human heart extracts, in patients with myocardial infarcts and in patients with skeletal muscle trauma. In infarct patients CK-Z levels paralleled changes in the CK-MB levels. CK-Z ranged in activity from 8.8-67.2 I.U. whereas CK-MB ranged from 29.6-121.6 I.U. in infarct patients. CK-Z and CK-MB activity were measured at or close to the peak rise in total CK activity.

Brain↗

The early detection of airway obstruction.

To assess the sensitivity of tests for early, small airway obstruction, we selected 52 cigarette smokers with a ratio of 1-sec forced expiratory volume to forced vital capacity greater than 70 per cent from a smoking cessation clinic. From these subjects, 29 of the 46 tested demonstrated frequency dependence of dynamic compliance, a finding arbitrarily defined as indicative of small airway obstruction in this group. Dynamic compliance was correlated with the British Medical Research Council questionnaire, routine pulmonary function tests, closing volume as a per cent of vital capacity, maximal expiratory flow-volume curves, and flow dependence of distribution of inhaled boluses of xenon-133 (finite difference Xe). Symptoms of respiratory disease, and abnormal flow-volume curves, specific conductances, and ratios of residual volume to total lung capacity were also present in some subjects, but they correlated very poorly with frequency dependence of dynamic compliance. On the other hand, finite difference Xe was abnormal in 85 per cent of cases with frequency dependence of compliance and closing volume was abnormal in 70 per cent. In 8 of 12 subjects restudied 2 months after they stopped smoking, dynamic compliance was less frequency dependent than before smoking cessation. Similar improvements were noted in finite difference Xe, but closing volume was unchanged. Although closing volume and dynamic compliance tended to be abnormal in the same subject, concordance was not excellent, and the effects of smoking cessation suggested that the 2 tests had different determinants.

Adult↗

Site of airway obstruction in asthma as determined by measuring maximal expiratory flow breathing air and a helium-oxygen mixture.

Because maximum expiratory flow-volume rates in normal subjects are dependent on gas density, the resistance between alveoli and the point at which dynamic compression begins (R(us)) is mostly due to convective acceleration and turbulence. We measured maximum expiratory flow-volume (MEFV) curves in asthmatics and chronic bronchitics breathing air and He-O(2). In the latter and in some asthmatics, MEFV curves did not change, indicating that R(us) is mostly due to laminar flow. Therefore, the point at which dynamic compression begins must be further upstream than in normal subjects and the site of obstruction must be in small airways. In other asthmatics, flow increased normally indicating obstruction in larger airways. The response to He-O(2) did not correlate with initial values of pulmonary resistance, the initial MEFV curves or the response to bronchodilators. We conclude that the site of airway obstruction varies among asthmatics and that the site of obstruction is not detectable by measurement of the usual parameters of lung mechanics.

Adolescent↗

A multivariable analysis of factors governing the steady-state pharmacokinetics of valproic acid in 52 young epileptics.

A number of factors have been implicated in the interpatient variability of valproic acid (VPA) pharmacokinetics. These include patient age, concurrent anticonvulsant therapy, and dosage of VPA. In the clinical setting, it is important to determine which of these variables exert a major effect on the observed differences in VPA disposition. Accordingly, we analyzed the data from 52 young epileptic patients using multivariate statistical methods. Concurrent anticonvulsant therapy was the major determinant of VPA clearance in this patient population. The half-life of VPA was significantly related to age, but volume of distribution and clearance were not. The dosage of VPA affected the volume of distribution of VPA but not the half-life or clearance of this drug. These results provide a more rational understanding of VPA pharmacokinetics in the clinical setting and have implications for the monitoring and manipulation of VPA therapy in the epileptic population.

Adolescent↗

Effect of point of care testing on length of stay in an adult emergency department.

Devices are now available that are practical for point of care testing (PCT) in hospital settings. Previous studies in clinical settings, however, have failed to demonstrate a reduction in patients' length of stay (LOS) associated with the use of PCT. This randomized controlled study compared PCT with central laboratory testing in a hospital Emergency Department to assess the difference in patients' LOS. Patients randomized to PCT (n = 93) had a median stay of 3 h, 28 min (interquartile range [IR] 2:28 to 5:30), while those allocated to the central laboratory (n = 87) had a median stay of 4 h, 22 min (IR 3:04 to 5:47). The median stay associated with PCT was significantly shorter. Among patients who were destined to be discharged home, there was also a significantly shorter stay, but not among those who were destined to be admitted. It was concluded that the use of PCT can achieve significant time savings in an Emergency Department.

Adolescent↗