PubMed HealthSearch

Biomedical subjects

M Limkeman

Publications and source records attributed to M Limkeman.

3 recordsLinked to original sources

Analysis of fluorescence decay kinetics from variable-frequency phase shift and modulation data.

Recently it has become possible to measure fluorescence phase-shift and modulation data over a wide range of modulation frequencies. In this paper we describe the analysis of these data by the method of nonlinear least squares to determine the values of the lifetimes and fractional intensities for a mixture of exponentially decaying fluorophores. Analyzing simulated data allowed us to determine those experimental factors that are most critical for successfully resolving the emissions from mixtures of fluorophores. The most critical factors are the accuracy of the experimental data, the relative difference of the individual decay times, and the inclusion of data measured at multiple emission wavelengths. After measuring at eight widely spaced modulation frequencies, additional measurements yielded only a modest increase in resolution. In particular, the uncertainty in the parameters decreased approximately as the reciprocal of the square root of the number of modulation frequencies. Our simulations showed that with presently available precision and data for one emission bandpass, two decay times could be accurately determined if their ratio were greater than or equal to 1.4. Three exponential decays could also be resolved, but only if the range of the lifetimes were fivefold or greater. To reliably determine closely-spaced decay times, the data were measured at multiple emission wavelengths so that the fractional intensities of the components could be varied. Also, independent knowledge of any of the parameters substantially increased the accuracy with which the remaining parameters could be determined. In the subsequent paper we present experimental results that broadly confirm the predicted resolving potential of variable-frequency phase-modulation fluorometry.

Kinetics

Resolution of mixtures of fluorophores using variable-frequency phase and modulation data.

We measured fluorescence phase shift and modulation data for one-, two- and, three-component mixtures of fluorophores at modulation frequencies ranging from 1 to 140 MHz. These data were analyzed using the least-squares procedure described in the preceding paper (Lakowicz, J. R., G. Laczko, M. Cherek, E. Gratton, and M. Limkeman, 1984, Biophys. J., 46:463-477). Using data obtained at a single emission bandpass, the lifetimes and preexponential factors of two-component mixtures could be easily resolved if the lifetimes differed by a factor of 2. With currently available instrumental stability, three-component mixtures could be resolved when the overall range of decay times was 10-fold, (e.g., 1.3, 4.4, and 12 ns). Measurement of phase and modulation data at several emission wavelengths, where the ratio of the preexponential factors varied, enhanced our ability to resolve closely spaced two and three-component decays. Two-component mixtures could then be resolved if the lifetimes differed by 30% (4.4 and 6.2 ns). Also, the multiple-wavelength data allowed the lifetimes and emission spectra of the three-components of a mixture to be resolved. These results demonstrated that resolution of multiexponential decay laws was possible using frequency-domain phase-modulation fluorometry.

Anthracenes

A continuously variable frequency cross-correlation phase fluorometer with picosecond resolution.

A detailed description of the construction and performance of a variable frequency cross-correlation phase fluorometer is reported. The phase fluorometer operates over the frequency range 1-160 MHz with a maximum resolution of a few picoseconds. The effects of distortions introduced by the light modulator and the nonlinear dynode characteristic are discussed in terms of the harmonic content of the detected signal. A source of systematic errors due to nonhomogeneous modulation is also discussed with particular attention to the color effect of the photomultipliers. The application of the phase fluorometer to the measurement of very long and very short lifetimes is reported. Some application to the measurement of multiexponential decays is also illustrated.