Assistant programming software: a new tool for an improved programming of pacemakers.

Programming the new DDD pacemakers is becoming increasingly difficult. One must take into account the pacemaker's complexity, the fact that some parameters are linked to others, and the clinical profile of the patient. This difficult problem will lead to the design of software to assist programming, which will help the implanting physicians in choosing adequate programmed settings adapted to the functioning of the device and to the physiology and pathology of the patient. These programming aides should meet certain basic requirements to make them safe, efficient, and easy to use. One such system designed by ELA Médical, "Programming Assistant" is herein described. The preliminary results of an initial study on the acceptance of this programming aide among physicians involved in cardiac pacing are given and discussed.

Adult↗

A new algorithm for a high level of protection against pacemaker-mediated tachycardia.

Pacemaker-mediated tachycardia (PMT) is a well-known complication of DDD pacing. PMT needs a permeable V-A conduction and is usually initiated by a premature ventricular or atrial systole, artifact sensing, or misprogramming (long AV delay [AVD]). Today, protection against PMT is expected from pacemaker multiprogrammability. Unfortunately, this prevention is often ineffective; postventricular atrial refractory period (PVARP) must be prolonged, which limits the upper tracking rate and the patient capacity. The new Chorus ELA Medical DDD pacemaker provides classic protection against PMT (PVARP prolongation after premature V or A complex, magnet application, noise sensing), but also automatically reduces an eventual PMT and adjusts AVD or PVARP for a high level of protection. The process is divided in four steps: (1) a sensing step for 16 cycles, with V-P conduction analysis; (2) confirmation of the presence of the PMT and analysis of V-A conduction time; (3) a termination step, by extending the PVARP after the following ventricular heart beat; and (4) in case of immediate recurrence of the tachycardia, reprogramming of the AVD and eventually of the PVARP. By first reducing AVD, before reprogramming PVARP, the pacemaker preserves point 2:1, providing a higher exercise capacity. This algorithm was successfully tested in three patients who had a permeable V-A conduction, without any adverse effect.

Algorithms↗