PubMed Health⌕ Search

Biomedical subjects

M Long

Publications and source records attributed to M Long.

108 records · Page 6Linked to original sources

Psychiatric diagnosis of morbidly obese gastric bypass patients.

Eighty morbidly obese patients who had had gastric bypass operations were interviewed for psychiatric diagnoses using DSM-III criteria. The lifetime prevalence of Axis I clinical psychiatric diagnoses was 47.5%, with depressive disorders occurring in 28.7% of the total sample. No other diagnosis exceeded a 2.5% prevalence. The authors believe there is no evidence of an increased prevalence of major psychiatric disorder in obese persons when strictly defined diagnostic criteria are used.

Adolescent↗

Effects of contingent payment on compliance with a naltrexone regimen.

The effects of several schedules of payment on duration and patterns of compliance with a naltrexone regimen were examined. Patients were paid under contingencies based on either number of doses ingested or on a fixed time schedule. Reinforcement schedules based on number of doses ingested produced more consistent treatment-oriented behavior than a time-based schedule. Covariation between behavior and alternating contingencies (A-B-A) indicated that the schedules contributed to increased duration of treatment compared to previous noncontingent payment. The issue of using extrinsic reinforcers such as monetary payment to enhance compliance is discussed and additional procedures are suggested.

Adult↗

Chiropody.

Explore the source record for details and available documents.

Foot Diseases↗

Effect of electric field on erythrocyte sedimentation rate. IV. Volume fraction dependence of human red cells in plasma.

We measured the volume fraction dependence of erythrocyte sedimentation for human red cells in autologous plasma while the volume fraction, Hct, ranges from 0.220 to 0.650. A modified electrophoretic instrument was employed to investigate the electric effect of an upward DC field on erythrocyte sedimentation at a constant source supply of Vs = 60.0 +/- 0.5 V. The sedimentation curves all coincided well with the sigmoidal type equation, l = lmax/¿l + (t50/t)n¿, at Vs = 0, or 60.0 V. Here, lmax is the length of plasma level, l, when the time, t, tends to infinity; t50 is the elapsed time when the plasma level falls to lmax/2, and n is a constant (n > 0). A non-linear least-squares method was employed to fit experimental data. It was found that lmax decreased and t50 increased with the increase of Hct, while n ranged from 1.53 to 3.95. The volume fraction dependence of sedimentation velocity, Vmax, defined as the maximum slope of the sedimentation curve, fits well with an exponential-type curve, both at Vs = 60.0 V and at Vs = 0 V: Vmax = Vs (1-Hct)exp(-BHct), where Vs is the velocity at infinite dilution and B is a phenomenological parameter. In the range of Hct = 0.220-0.650, Vs and B are 326.1 mm/hr and 4.30, respectively, at Vs = 60.0 V, while they are 130.4 mm/hr and 2.46, respectively, at Vs = 0 V.

Blood Sedimentation↗

A comparison of the Ameroid constrictor versus ligation in the surgical management of single extrahepatic portosystemic shunts.

Twenty-two dogs were managed surgically for a single extrahepatic portosystemic shunt; 12 with surgical ligation and 10 with an Ameroid constrictor. Utilization of the Ameroid constrictor significantly decreased surgery time to approximately half that of the ligation technique. A decreased intraoperative and postoperative complication rate was noted with the Ameroid constrictor group. Follow-up evaluation demonstrated comparable efficacy when comparing surgical techniques. The Ameroid constrictor offered a surgical occlusion technique for management of a single extra-hepatic portosystemic shunt that was equally effective to ligation while shortening surgical time and minimizing the risks that are commonly associated with ligation of the shunting vessel.

Animals↗

Liquid chromatographic method for determination of patulin in clear and cloudy apple juices and apple puree: collaborative study.

A collaborative trial was conducted to validate the effectiveness of a liquid chromatographic (LC) procedure for determination of patulin in both clear and cloudy apple juices and apple puree. The test portion of clear apple juice was directly extracted with ethyl acetate; cloudy apple juice and apple puree were treated with pectinase enzyme before extraction. After back-extraction into sodium carbonate to remove interfering acidic compounds, the extract was dried and concentrated, and patulin was determined by LC with UV detection. Clear and cloudy apple juices, apple puree test samples naturally contaminated with patulin, and blank test samples for spiking with patulin were sent to 14 collaborators in 12 different European countries. Test portions of each of the 3 test sample types were spiked with patulin at 75 ng/g. Recoveries of patulin ranged from 80 to 92%. Based on the results for spiked test samples (blind pairs) and naturally contaminated test samples (blind pairs at 3 levels), the relative standard deviations for repeatability (RSDr) and reproducibility (RSDR) ranged from 8 to 35% and 11 to 36%, respectively. Although HORRAT values of <1.4 were obtained for all 3 matrixes at patulin levels ranging from 26 to 121 ng/g, better performance values (RSDr values 6-10% and RSDR values 11-25%) were obtained for clear and cloudy apple juice spiked above 50 ng/g, which is either the statutory limit or the advisory level for patulin contamination in apple juices in many countries.

Beverages↗

Titling and licensure.

Explore the source record for details and available documents.

American Nurses' Association↗