PubMed Health⌕ Search

Biomedical subjects

M Luszik-Bhadra

Publications and source records attributed to M Luszik-Bhadra.

26 records · Page 2Linked to original sources

A prototype personal neutron dosemeter with one silicon diode.

The performance of a personal neutron dosemeter with a single silicon diode using a linear combination of its pulse height information was studied. Its dosimetric behaviour in fields with neutrons of different energy and directional distribution is shown for neutron energies ranging from thermal to 100 MeV and for directions of incidence ranging from frontal to lateral. The dosemeter is photon-insensitive and its dose detection threshold is at about 20 microSv. The dosimetric characteristics are compared with those of commercial dosemeters based on silicon detectors.

Consumer Product Safety↗

Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy.

Photoneutron production was investigated on Siemens KD 2 and Varian Clinac accelerators operating in the 6-18 MV range. Neutron dose equivalent rates were measured on the surface of a water phantom at the isocenter of the accelerators and also inside the phantom at depths of 1, 5, and 10 cm and off-axis distances of 0, 20, and 50 cm. Superheated drop detectors based on dichlorofluoromethane and etched-track detectors with boronated converters were employed in this study. The energy response of these detectors permits a direct measurement of dose equivalent without prior knowledge of the neutron energy spectra. Dose equivalent rates were assessed using the Q(L) relationship from ICRP publication 60, as well as using earlier data from ICRP publication 21. This permitted both a comparison with previously published data and an assessment of the impact of the recent ICRP recommendations--which were found to increase the dose equivalent levels by about 30%. In addition, the depth corresponding to 50% of maximum dose equivalent, dH50, was determined along the central axis of the beams and at 50 cm off-axis. Monte Carlo neutron transport calculations were performed to determine the depth-dose equivalent distributions in a phantom irradiated with monoenergetic neutrons. Effective energies of the photoneutron spectra were then estimated by comparing our measured dH50 values to those calculated for monoenergetic neutrons. It was found that the effective photoneutron energy is 1.8-2.1 MeV within the 10-18 MV x-ray beams, and it is 0.5-0.8 MeV for photoneutrons transmitted through the accelerator head. Data from this work cover most of the x-ray beam energies in clinical use and permit an assessment of integral dose values as well as specific organ doses to a radiotherapy patient.

Humans↗

Personal neutron dosimetry in the space station MIR and the Space Shuttle.

A passive neutron dosemeter based on nuclear track detectors and TLD's was used in 1995 and 1997 on the MIR station and in Space Shuttle flights to MIR. As it is equipped with neutron converters and shieldings of different types the track detector system allows the neutron dose equivalent to be determined in rough energy intervals. The results of the measurements on the MIR station and in the Space Shuttle flights are presented and the influence of charged particles in the complex mixed radiation field in space is discussed. Improvements are possible by means of a new active neutron dosemeter which is under development at the PTB. First measurements with a prototype in the high-energy reference fields at CERN are presented and discussed.

Equipment Design↗