Narrow line photoassociation in an optical lattice.

With ultracold 88Sr in a 1D magic wavelength optical lattice, we performed narrow-line photoassociation spectroscopy near the 1S0 - 3P1 intercombination transition. Nine least-bound vibrational molecular levels associated with the long-range 0u and 1u potential energy surfaces were measured and identified. A simple theoretical model accurately describes the level positions and treats the effects of the lattice confinement on the line shapes. The measured resonance strengths show that optical tuning of the ground state scattering length should be possible without significant atom loss.

Journal Article↗

X-ray image intensifier performance and patient doses for combinations of supplemental beam filters and vascular contrast agents.

We present an investigation of the fluoroscopic imaging and dosimetric performances of iodine- and gadolinium-based vascular contrast agents in combination with K-absorption edge filters of atomic numbers between 50 (tin) and 82 (lead). These combinations were studied using a theoretical model for a range of diagnostic x-ray spectra (55 to 100 kVp) and for water phantoms representative of thin and thick anatomies. Performance was characterized by radiographic contrast, a derived image quality index, the patient integral and entrance skin doses, and the x-ray tube load. For a given thickness of anatomy, an optimum combination of spectrum kVp, contrast agent and supplemental filter was defined by maximum imaging performance for a minimum or tolerable x-ray tube load and patient dose. It was possible to both improve imaging performance and reduce dose by the use of an appropriate combination of spectrum kVp and filter. For gadolinium-based contrast, performance was optimized with tungsten filtration at 90 kVp for both thin and thick anatomies. It was not possible, however, to optimize the iodinated contrast performance with a single combination of supplemental filter and spectrum kVp. The optimal performance for iodinated contrast was achieved with gadolinium filtration at 60 kVp for thin anatomy and with ytterbium filtration at 80 kVp for thick anatomy. The best performance for thin anatomy was that of the combination of iodinated contrast/gadolinium filter at 60 kVp and the best performance for thick anatomy was that of the combination of gadolinium-based contrast/tungsten filter at 90 kVp.

Chromatography, Gel↗

A comparison of fixed and variable kVp technique protocols for film-screen mammography.

Mammographic image quality, contrast and dose for a variable tube potential (kVp) technique protocol for film-screen mammography have been investigated. In this protocol, the tube potential is increased for larger breast thicknesses. Comparisons were made with fixed kVp protocols, in which the tube potential is kept constant and the breast thickness compensated for by prolonging the exposure ("fixed kVp" protocol). All measurements were performed on a mammography unit with a molybdenum target and filter. Image quality was quantified by image contrast, image detail detection and the minimum detectable dimension of low contrast objects. It was demonstrated that for a compressed breast thickness of less than about 40 mm, varying the tube potential had a negligible effect upon dose but a significant effect upon image quality. For a compressed breast thickness greater than about 60 mm, the effect of the tube potential upon image quality was much reduced; however, the effect upon dose was significantly greater. The variable kVp protocol takes advantage of this feature to yield a significantly lower dose for thicker breasts with a small reduction in image quality, often only within experimental uncertainty. For an exposure under automatic exposure control, increasing the tube potential from 26 kVp to 30 kVp for a breast of a reference tissue composition (50% adipose and 50% glandular) with a compressed thickness of 60 mm reduced the mean glandular dose from 6 mGy to 3.9 mGy (-35%), but increased the minimum detectable dimension of a low contrast mass from 0.8 (+/- 0.1) mm to 1.1 (+/- 0.1) mm. Adopting a variable kVp protocol led to a median patient mean glandular dose per film of 2.7 mGy, nearly independent of compressed breast thickness. In our survey, the mean age of women presenting for mammography is younger and the mean compressed breast thickness is less than reported from screening centres. This suggests that there will be a higher proportion of denser, glandular tissue in the breasts incorporated within this survey than for surveys from screening centres. The clinical use of the variable kVp protocol allows the extraction from patient data of separate changes in breast composition which are due to patient age and breast thickness. It is concluded that the reference breast tissue composition is not an accurate representation of the women presenting at this centre.

Adolescent↗

Optimizing optical density of a Kodak mammography film-screen combination with standard-cycle processing.

The optimization of optical density in film-screen mammography is crucial in attaining good image quality. While a target range for film optical density of 1.4-1.8 has been recommended for centres participating in the National Health Service Breast Screening Programme (NHSBSP), past investigations have shown that combinations of mammography film and screen and processor conditions can have various optimum densities, some of which are outside this recommended range. The optimum optical density of the film/screen/processor conditions combination used at our institution (the Kodak MIN-RM/MIN-R combination designed for standard-cycle processing) was evaluated using a breast detail phantom study. It was found that the optimum optical density was 1.25 OD. We recommend that an individual institution determines the optimum optical density for the film-screen combination it uses and the processing conditions specific to it.

Mammography↗