PubMed Health⌕ Search

Biomedical subjects

M M Chen

Publications and source records attributed to M M Chen.

At least 55 records · Page 3Linked to original sources

A technique for measuring the thermal conductivity and evaluating the "apparent conductivity" concept in biomaterials.

A simple technique for measuring thermal conductivity of biomaterials is described. The method is based on depositing a pulse of heat into the material of choice, and fitting the subsequent local temperature decay to that predicted by a theoretical model. This transient method is most suitable in situations where frequent measurements of the thermal conductivity are desired. The method was evaluated by calculating the thermal conductivity of several inert materials. The measured conductivities compared well with published values. The developed technique was also used to examine the applicability of the "apparent conductivity" index to combine both conductive and blood-convective thermal effects in living, blood perfused tissues. Using both simulated and experimental results, it was shown that the changes in the apparent conductivity are highly correlated with changes in blood flow. However, quantitative application of this index must be restricted to conditions that are similar to those which existed at the time the apparent conductivity was measured.

Agar↗

Computer-based system for continuous on-line measurements of tissue blood perfusion.

We describe a new system for an almost continuous, on-line measurement of local blood perfusion in living tissue. The technique uses a thermal method based on measurements of the tissue temperature decay after a short pulse (approximately equal to 3 s) of local heating. The instrumentation system consists of six small thermistor microprobes, a probe interface unit and a DEC LSI-11/23 microcomputer. The system is equipped with six thermistor channels, and the number can be increased with further signal conditioning modules, thereby increasing the locations at which blood perfusion can be measured. The results agree favourably with values for tissue blood flow obtained simultaneously using either the microspheres method or an electromagnetic probe. The system has been in use for three years and there is good reason to believe that it can be reliably applied in many situations where a continuous multichannel monitor of local blood perfusion is necessary.

Animals↗

Theory on thermal probe arrays for the distinction between the convective and the perfusive modalities of heat transfer in living tissues.

Recent suggestions for an improved model of heat transfer in living tissues emphasize the existence of a convective mode due to flowing blood in addition to, or even instead of, the perfusive mode, as proposed in Pennes' "classic" bioheat equation. In view of these suggestions, it might be beneficial to develop a technique that will enable one to distinguish between these two modes of bioheat transfer. To this end, a concept that utilizes a multiprobe array of thermistors in conjunction with a revised bioheat transfer equation has been derived to distinguish between, and to quantify the perfusive and convective contribution of blood to heat transfer in living tissues. The array consists of two or more temperature sensors one of which also serves to locally insert a short pulse of heat into the tissue prior to the temperature measurements. A theoretical analysis shows that such a concept is feasible. The construction of the system involves the selection of several important design parameters, i.e., the distance between the probes, the heating power, and the pulse duration. The choice of these parameters is based on computer simulations of the actual experiment.

Animals↗

A sensitivity analysis of the Thermal Pulse Decay method for measurement of local tissue conductivity and blood perfusion.

The Thermal Pulse Decay (TPD) method for the determination of local tissue thermal conductivity and blood perfusion rate is based on a comparison of measured with theoretically calculated temperatures. A sensitivity analysis of the theoretical model is performed. This analysis supports the establishment of an experimental protocol which reduces the measurement errors: An "optimal" measurement time interval for typical perfusion rates (up to 6 mL/mL/min) was found to be between 3 and 11 s after the heat pulse is turned off. Within this interval, the maximum error in determination of tissue conductivity and blood perfusion caused by experimental measurement errors is expected not to exceed 5 percent. The presently chosen pulse duration of 3 s is in agreement with the analysis as a good compromise between accuracy and excessive tissue heating.

Humans↗

Thermal pulse decay method for simultaneous measurement of local thermal conductivity and blood perfusion: a theoretical analysis.

Presented here is a theoretical analysis of the recently developed thermal pulse decay (TPD) method for a simultaneous measurement of local tissue conductivity and blood perfusion rate. The paper describes the theoretical model upon which the TPD method is based and details its capabilities and limitations. The theoretical aspects that affected the development of the measurement protocol are also discussed. The performance of the method is demonstrated with an experimental example which compares the measurements of local kidney blood perfusion rates made using the TPD method with the total renal blood flow obtained coincidentally using a blood flowmeter, in an anesthetized dog.

Animals↗

Adaptive thermal modeling: a concept for measurement of local blood perfusion in heated tissues.

A new Adaptive Thermal Modeling (ATM) method for the measurement of local tissue blood perfusion rate is introduced. The method is based on a two-phase numerical technique. The first phase includes a fast, finite difference scheme for solution of the transient temperature field. The second phase involves iterative corrections of the perfusion until the modeled temperatures coincide with those measured by the temperature sensors. The results obtained from computer generated "data", as well as from laboratory experiments demonstrate the potential capability of the ATM method to continuously measure local perfusion rates in heated tissues. Rigorous analysis of the technique is planned for the near future so that it can be applied to in vivo measurements of local tissue blood perfusions.

Adaptation, Physiological↗

Cimetidine--acetaminophen interaction in humans.

The effect of single-dose and multiple-dose cimetidine administration on acetaminophen pharmacokinetics was investigated in a three-phase, randomized, crossover study using four normal subjects. In each phase of the study, subjects ingested 750 mg of acetaminophen as a single dose alone (A), or in combination with 200 mg of cimetidine (A + C), or following a one-week pretreatment with daily cimetidine, 200 mg every six hours and 400 mg before retiring (A + C*). Statistical analysis using two-way analysis of variance indicated no significant difference in peak concentration and peak time of acetaminophen between treatments. Cimetidine did not significantly affect acetaminophen half-life, 2.38 hours (A), 2.65 hours (A + C), and 2.50 hours (A + C*). Acetaminophen clearance was minimally affected by cimetidine; the mean clearance of acetaminophen ranged from 4.16 (A + C*) to 5.57 mL/min/kg (A). Area under the acetaminophen plasma concentration-time curve was slightly increased by cimetidine, 35.4 (A), 41.6 (A + C), and 47.6 micrograms/mL/h (A + C*). Since cimetidine did not affect acetaminophen pharmacokinetics to any significant extent, clinical combination of both medications at therapeutic dosage presumably would not produce adverse interactions.

Acetaminophen↗

Proposed methods for the measurement of regional renal blood flow using heat transfer analysis.

The kidney, with its heterogeneous regional perfusion in the two anatomically and functionally distinct vascular beds of the renal cortex and medulla, and with its non-uniform blood vessel geometries, presents a unique challenge for measuring intrarenal blood flow distribution. Determining whole organ perfusion, on the other hand, is comparatively simple for the kidney, but it provides relatively little information about the suspected dependency of renal excretory function on local perfusion rate. Among the variety of methods proposed for gauging regional renal blood flow, some depend on measuring one or more of the tissue's thermal properties. The most straightforward, but least reliable, involve measurements either of focal tissue temperature alone, or of regional tissue thermal gradients. Simply using heat as a diffusible indicator, however, is unreliable as a measure of blood flow, for many of the same reasons that using an inert gas in a dilution technique is unreliable. Recently developed thermal analytical methods, though, hold promise for measuring local tissue blood flow with accuracy and precision. Two of them are reviewed here. One depends on measurement of the effective thermal conductivity of a small mass of tissue by evaluating the steady state ratio between regional unidirectional heat flux across it and the associated temperature gradient in one vector along a segment of it through an imposed spheroidal heat field. The other depends on analyses of tissue temperature decay subsequent to a controlled pulse of heat delivered through a small inserted thermistor bead. Both techniques use bioheat transfer equations to deduce regional blood flow by differentiating between heat dissipation due to local thermal conductivity and that attributable to the effects of regional convection. Although both methods are unavoidably invasive, neither produces debilitating damage in the tissue volume in which perfusion is measured, nor increases local temperature or metabolism enough to affect blood flow itself. Both techniques quantify local blood flow in small volumes of tissue by detailed evaluation of the many properties of tissue and blood which affect heat transfer, and both allow for a virtually unlimited number of nearly continuous sequential measurements at short (nom. 1 min) time intervals.

Animals↗

Absorption and disposition of ethambutol in rabbits.

The absorption and disposition of ethambutol was examined in six rabbits in a three-way crossover study. Each rabbit received 45-mg/kg doses of ethambutol in three treatments: one intravenous injections and two oral solutions, ethambutol alone and ethambutol in the presence of aluminum hydroxide (40 mg/kg). Half-lives of ethambutol ranged from 2.26 to 5.20 h when administered alone and 2.18 to 4.00 h when coadministered with the antacid; the difference was not significant (p greater than 0.3). Mean clearance after the oral administrations (189.2 mL/min/kg) was significantly greater than the mean intravenous clearance (43.7 mL/min/kg) (p less than 0.01), suggesting a first-pass metabolism of ethambutol when administered nonparenterally to rabbits. The volume of distribution ranged from 5.5 to 17.8 L/kg, suggesting an extensive distribution of ethambutol outside the central compartment and, possibly, a localized deposit within the body tissues. Mean bioavailability of ethambutol was approximately 28% and was not affected by the presence of aluminum hydroxide. The rate of ethambutol absorption, however, was slightly delayed by the antacid.

Aluminum Hydroxide↗

Acetaminophen-aluminum hydroxide interaction in rabbits.

Acetaminophen-aluminum hydroxide interaction was investigated in a crossover study using six rabbits. Blood samples were collected at various time intervals for up to 6 hr following the oral administration of acetaminophen alone or in combination with aluminum hydroxide. Aluminum hydroxide at a 40-mg/kg dose did not appear to affect the rate and extent of acetaminophen absorption. The influence of aluminum hydroxide on gastric emptying could be compromised by gastric absorption of acetaminophen, resulting in a negligible effect on the overall bioavailability of acetaminophen.

Acetaminophen↗

[Evaluation of the GNF computer-coding system for the identification of non-fermentative Gram-negative bacilli].

In order to evaluate the effectiveness of the GNF computer-coding system for the identification of glucose non-fermenting gram-negative bacilli, we employed 406 strains of bacteria including 367 clinical isolates and 39 standard strains for testing. These strains were inoculated into the following eleven conventional biochemical test media: Triple Sugar Iron Agar, Simmon's Citrate Agar, Christensen's Urea Agar, Sulfide-Indole-Motility Medium, Semisolid Voges-Proskauer Test Medium, Moeller's Ornithine Decarboxylase Test Medium, Pyocyanin Test Medium, Oxidation/Fermentation (O/F) Glucose, O/F Fructose, Nitrate Broth, Moeller's Arginine Dihydrolase Test Medium. The results of these tests plus those from the hanging drop motility test and the oxidase test were converted into bacterial code number and then checked with the GNF computer-coding system. It was found that the first preference of agreement was 75.6%, second 15.3%, third 5.9%, and fourth or more 3.2%. In regard to the speed of bacterial identification by using the GNF system and information from hemolysis pattern and flagella stain, it was indicated that 84.7% would be correctly identified within 36-48 hours after isolation. If more confirmational tests were employed, the accurate identification rate would reach to 98.7% after 4 days of isolation. In addition, the use of the GNF computer-coding system can standardize identification procedures, shorten the identification period, and save cost in terms of materials supply, inoculation time, media preparation and media-storing space. Therefore, we conclude that the GNF computer-coding system is an effective tool in the identification of the glucose non-fermenting gram-negative bacilli.

Computers↗

Pulse-decay method for measuring the thermal conductivity of living tissues.

The present communication presents a single microprobe technique for measuring tissue thermal properties based on the dissipation of a measured amount of energy and the observation of the resulting temperature rise a given time later. An advantage of this method is that the effective sampling volume can be varied by varying the measurement time. Using a measurement time of a few seconds, the sampling volume was estimated to be several orders of magnitude greater than the probe volume. Hence artifacts due to probe-induced trauma or stress would be insignificant. Additional advantages of the technique are: the results were independent of the probe shape, size and properties, and hence represents absolute measurements without the need for calibration; the required electronics and computations are simple; the determination of thermal conductivity requires only a single measurement; and comparison of data at different measurement times yields a clear and unequivocal indication of nonconductive contributions of heat transfer, if present.

Biomechanical Phenomena↗

Maximizing health system output with political and administrative constraints using mathematical programming.

Decisions about delivery programs to improve health status are characterized by indivisibilities or "lumpiness," interdependencies between case types with varying health output, high fixed costs, administrative constraints, and qualitative quity and political considerations. The nature of the constraints and the goal of health services strongly suggest a mathematical programming model to maximize a comprehensive measure of health status. In a previously unreported development, binary integer programming can be extended to consider shared fixed costs, a widespread problem in optimizing effectiveness measures such as health status. The model proposed here applies conceptually across all target populations and health programs and could be used to optimize the output of a total health system. The effects of such optimization would be appropriately reflected in the weighted life expectancy computed as a social indicator.

Cost-Benefit Analysis↗

No-fault malparactice insurance. Proximate cause and the quality of medical care.

No-fault medical malpractice insurance has been proposed as an alternative to the present tort liability approach. Statistical examination of the concept of proximate cause reveals not only that the question of acceptable care, and therefore of fault, is unavoidable in identifying patients deserving compensation, but also that specifying fault in an individual case is scientifically untenable. A simple formula for a Coefficient of Causality clarifies the question of proximate cause in existing trial practices and suggests that many of the threats associated with malpractice suits arise from the structure of the tort-insurance system rather than from professional responsibility for medical injury. The concepts could provide the basis for a revised claims and compensation procedure.

Expert Testimony↗