PubMed Health⌕ Search

Biomedical subjects

M M Fejer

Publications and source records attributed to M M Fejer.

18 recordsLinked to original sources

Enhanced second-harmonic generation in AlGaAs/AlxOy tightly confining waveguides and resonant cavities.

We demonstrate second-harmonic generation (SHG) from sub-micrometer-sized AlGaAs/AlxOy artificially birefringent waveguides. The normalized conversion efficiency is the highest ever reported. We further enhanced the SHG using a waveguide-embedded cavity formed by dichroic mirrors. Resonant enhancements as high as approximately 10x were observed. Such devices could be potentially used as highly efficient, ultracompact frequency converters in integrated photonic circuits.

Journal Article↗

Dichroic mirror embedded in a submicrometer waveguide for enhanced resonant nonlinear optical devices.

We report the design, fabrication and characterization of novel dichroic mirrors embedded in a tightly confining AlGaAs/Al(x)O(y) waveguide. Reflection at the first-harmonic wavelength as high as 93% is achieved, while high transmission is maintained at the second-harmonic wavelength. The measured cavity spectrum is in excellent agreement with finite-difference time-domain simulations. Such a mirror is essential for achieving resonant enhancement of second-harmonic generation.

Journal Article↗

High resolution polar Kerr effect measurements of Sr2RuO4: evidence for broken time-reversal symmetry in the superconducting state.

The polar Kerr effect in the spin-triplet superconductor Sr2RuO4 was measured with high precision using a Sagnac interferometer with a zero-area Sagnac loop. We observed nonzero Kerr rotations as big as 65 nanorad appearing below Tc in large domains. Our results imply a broken time-reversal symmetry state in the superconducting state of Sr2RuO4, similar to 3He-A.

Journal Article↗

Fiber-laser frequency combs with subhertz relative linewidths.

We investigate the comb linewidths of self-referenced, fiber-laser-based frequency combs by measuring the heterodyne beat signal between two independent frequency combs that are phase locked to a common cw optical reference. We demonstrate that the optical comb lines can exhibit instrument-limited, subhertz relative linewidths across the comb spectra from 1200 to 1720 nm with a residual integrated optical phase jitter of approximately 1 rad in a 60 mHz to 500 kHz bandwidth. The projected relative pulse timing jitter is approximately 1 fs. This performance approaches that of Ti:sapphire frequency combs.

Journal Article↗

Cavity with a deformable mirror for tailoring the shape of the eigenmode.

We demonstrate an optical cavity that supports an eigenmode with a flattop spatial profile--a profile that has been proposed for the cavities in the Advanced Laser Interferometer Gravitational Wave Observatory, the second-generation laser interferometric gravitational wave observatory--because it provides better averaging of the spatially dependent displacement noise on the surface of the mirror than a Gaussian beam. We describe the deformable mirror that we fabricated to tailor the shape of the eigenmode of the cavity and show that this cavity is a factor of 2 more sensitive to misalignments than a comparable cavity with spherical mirrors supporting an eigenmode with a Gaussian profile.

Journal Article↗

Narrow-linewidth near-degenerate optical parametric generation achieved with quasi-group-velocity-matching in lithium niobate waveguides.

We demonstrate narrow-linewidth near-degenerate optical parametric generation in reverse-proton-exchange lithium niobate waveguides with quasi-group-velocity-matching, which is realized by using wavelength-selective directional couplers and tight-radius bends. With appropriate designs for 1.6 ps long pump pulses at 785.1 nm we obtained near-degenerate signal (idler) pulses with a time-bandwidth product as low as 1.1, compared with 10.5 for conventional devices without quasi-group-velocity-matching. This improvement in the temporal property is a result of both a pulse compression effect and a filter effect coming from our scheme of quasi-group-velocity-matching.

Journal Article↗

1.5 microm photon-counting optical time-domain reflectometry with a single-photon detector based on upconversion in a periodically poled lithium niobate waveguide.

Optical time-domain reflectometry (OTDR) is one of the most powerful tools in the characterization of optical fiber links. We demonstrate a photon-counting OTDR system at 1.5 microm with a single-photon detector, which combines frequency upconversion in a periodically poled lithium niobate waveguide and a silicon avalanche photodiode. The system exhibits high sensitivity, good spatial resolution, and short measurement time.

Journal Article↗

Two-spatial-mode parametric amplifier in lithium niobate waveguides with asymmetric Y junctions.

For optical parametric amplifiers in proton-exchange waveguide devices reported to date, both the signal and the idler photons are in the TM00 mode, causing difficulty in distinguishing signal from idler. We report a two-mode optical parametric amplifier. The key components, asymmetric Y junctions, successfully launch the pump wave in a pure TM10 mode and separate the signal and the idler in the TM10 and TM00 modes with a power ratio of as much as 27.5 dB. With high parametric gain, optical parametric generation with a threshold of 300 pJ/pulse was demonstrated for 1.8 ps long pump pulses near 780 nm. These periodically poled lithium niobate waveguides are efficient integrable photon sources.

Journal Article↗

Amplitude modulation and apodization of quasiphase-matched interactions.

We propose several techniques to modulate the local amplitude of quasi-phase-matched (QPM) interactions in periodically poled lithium niobate waveguides and demonstrate apodization by using each of these techniques. When the hard edges are removed in the spatial profile of the nonlinear coupling, the sidelobes of the frequency tuning curves are suppressed by 13 dB or more, compared with a uniform grating, consistent with theoretical predictions. The sidelobe-suppressed gratings are useful for frequency conversion devices in optical communication systems to minimize interchannel cross talk, while the amplitude modulation techniques in general have potential uses in applications that require altering the tuning curve shapes.

Journal Article↗

Optical parametric generation of a mid-infrared continuum in orientation-patterned GaAs.

We have generated an ultrabroad mid-infrared continuum by using single-pass optical parametric generation (OPG) in orientation-patterned GaAs (OP-GaAs). The spectrum spans more than an octave, from 4.5 to 10.7 microm, measured 20 dB down from the peak. The 17.5 mm long, 0.5 mm thick, all-epitaxially-grown OP-GaAs sample with a 166.6-microm quasi-phase-matching period was pumped with 3.1-3.3 microm wavelength, 1 ps pulses up to 2 microJ in energy. The OPG threshold was observed at 55 nJ pump energy with the pump polarized along the [111] crystal direction. The slope efficiency near threshold was 51%, and the external conversion efficiency was as high as 15%.

Journal Article↗

Highly efficient single-photon detection at communication wavelengths by use of upconversion in reverse-proton-exchanged periodically poled LiNbO3 waveguides.

Conventional single-photon detectors at communication wavelengths suffer from low quantum efficiencies and large dark counts. We present a single-photon detection system, operating at communication wavelengths, based on guided-wave frequency upconversion in a nonlinear crystal with an overall system detection efficiency (upconversion + detection) exceeding 46% at 1.56 microm. This system consists of a fiber-pigtailed reverse-proton-exchanged periodically poled LiNbO3 waveguide device in conjunction with a silicon-based single-photon counting module.

Journal Article↗

Tandem chirped quasi-phase-matching grating optical parametric amplifier design for simultaneous group delay and gain control.

We present a broadband optical parametric amplifier design using tapered gain and tandem chirped quasi-phase-matching gratings to obtain flat gain and group-delay spectra suitable for applications such as ultrashort-pulse amplification and fiber-optic communication systems. Although a tapered-gain amplifier consisting of a single chirped grating can provide constant gain over a wide frequency range, it cannot be used to control the group delay across the spectrum. We propose controlling both the gain and the group delay profiles using a two-stage amplifier configuration, in which the idler of the first is used as the input signal of the second.

Journal Article↗

Quasi-group-velocity matching using integrated-optic structures.

We propose a device to compensate for group-velocity mismatch (GVM) effects that limit the efficiency-bandwidth product in nonlinear frequency-mixing devices. Integrated wavelength-dependent delay lines are introduced periodically in a waveguide containing a series of quasi-phase-matching (QPM) gratings. Appropriate choice of the time delays can compensate for GVM. We have demonstrated a two-stage device in a periodically poled lithium niobate waveguide. Two approximately 150-fs-long pulses generated 6 ps apart by second-harmonic generation in two QPM gratings were resynchronized by a fixed delay line, and their relative phase was fine controlled by temperature tuning. This technique, which can be iterated to more than two segments, permits optical frequency mixers with a higher efficiency-bandwidth product than would be possible in a single grating short enough to avoid GVM effects.

Journal Article↗

Optical parametric oscillation in quasi-phase-matched GaAs.

We demonstrate an optical parametric oscillator (OPO) based on GaAs. The OPO utilizes an all-epitaxially-grown orientation-patterned GaAs crystal that is 0.5 mm thick, 5 mm wide, and 11 mm long, with a domain reversal period of 61.2 microm. Tuning either the near-IR pump wavelength between 1.8 and 2 microm or the temperature of the GaAs crystal allows the mid-IR output to be tuned between 2.28 and 9.14 microm, which is limited only by the spectral range of the OPO mirrors. The pump threshold of the singly resonant OPO is 16 microJ for the 6-ns pump pulses, and the photon conversion slope efficiency reaches 54%. We also show experimentally the possibility of pump-polarization-independent frequency conversion in GaAs.

Journal Article↗

Vapor-transport equilibrated near-stoichiometric lithium tantalate for frequency-conversion applications.

Near-stoichiometric lithium tantalate (SLT) crystals were produced from congruent lithium tantalate by a vapor-transport equilibration process. Because of the resultant increase in photoconductivity and reduction in photogalvanism, the crystals showed no observable photorefractive damage at 514.5 nm up to the highest intensity used, 2 MW/cm2. The crystals also exhibited low green-induced infrared absorption, a Curie temperature of 693 degrees C, and a coercive field of 80 V/mm. The SLT samples were periodically poled with an 8-microm-period grating, permitting first-order quasi-phase-matched second-harmonic generation of 532-nm radiation at 43 degrees C. A 17-mm-long sample generated 1.6 W of continuous-wave output power at 532 nm for 50 h. With 150-ns pulses at a 100-kHz repetition rate in the same sample, 5-W average-power, 532-nm radiation was generated for 1000 h. No damage to the crystal and no aging effects were observed during these experiments.

Journal Article↗

Periodically poled lithium niobate waveguide sum-frequency generator for efficient single-photon detection at communication wavelengths.

We present a device to facilitate single-photon detection at communication wavelengths based on continuous-wave sum-frequency generation with an upconversion efficiency exceeding 90%. Sum-frequency generation in a periodically poled lithium niobate waveguide is used to upconvert signal photons to the near infrared, where detection can be performed efficiently by use of silicon avalanche photodiodes.

Journal Article↗

Direct imaging of multimode interference in a channel waveguide.

By use of a near-field scanning optical microscope in collection mode, multimode interference was directly measured in an annealed proton-exchanged LiNbO3 waveguide. Periodic transitions from a single-peaked Gaussianlike intensity distribution to a double-peaked intensity distribution were observed. The intensity distribution along the waveguide was calculated, and the results agree well with the experimental observation.

Journal Article↗

Light-emitting diodes: a novel light source for phototherapy.

High intensity light-emitting diodes (LEDs) are being studied as possible light sources for the phototherapy of hyperbilirubinemic neonates. These power-efficient, low heat-producing light sources have the potential to deliver high intensity light of narrow wavelength band in the blue-green portion of the visible light spectrum, which overlaps the absorption spectrum of bilirubin (BR). We compared the efficacy between single LEDs of different color and then constructed a prototype phototherapy device using 300 blue LEDs. The efficacy of this device was compared with that of conventional phototherapy devices by measuring the in vitro photodegradation of BR in human serum albumin. When blue, blue-green, green, and white LEDs were compared, the blue light was the most effective in degrading BR by 28% of dark control, followed by blue-green (18% of control), and then white light (14% of control). Green light was the least effective (11% of control). The prototype device with three focused arrays, each with 100 blue LEDs, generated greater irradiance (> 200 microW.cm-2.nm-1) than any of the conventional devices tested. It also supported the greatest rate of BR photodegradation. We conclude that light from LEDs should be considered a more effective treatment for hyperbilirubinemia than light from presently used phototherapy devices. Furthermore, the unique characteristics of this light source may make it especially suitable for use in safe and lightweight home phototherapy devices.

Color↗