PubMed Health⌕ Search

Biomedical subjects

M M Gross

Publications and source records attributed to M M Gross.

At least 19 recordsLinked to original sources

[Out-of-hospital births in Germany--a comparison of "large", "medium", and "small" free-standing birth centres].

BACKGROUND: How do maternal and foetal outcomes in out-of-hospital births vary in relation to birth centre size? PATIENTS AND METHODS: Routine perinatal data from out-of-hospital births in 80 birth centres in Germany between 1999 and 2002 were analysed. Birth centres were grouped according to their annual mean birth rate into small (< or = 70 births per year), medium (71 - 155 births per year), and large (> 155 births per year) units. Breech births (n = 43) and twins (n = 14) were excluded from the analysis (level of significance p < 0.01). RESULTS: Pregnancy and perinatal risks, foetal and maternal morbidity and mortality, perineal lacerations and transfer of newborns to NICU did not differ between the three groups which comprised a total of 14,629 births. Less episotomies were performed in large birth centres compared to small or medium-sized birth centres. Significantly less women were transferred from medium-sized birth centres to hospital following delivery. Five minute Apgar scores < or = 7 were significantly more frequent in birth centres with the highest birth rates. During labour significantly less women were transferred to hospital from medium-sized birth centres than from small or large centres. The transfer rate difference between nulliparae and multiparae was 4 : 1. CONCLUSION: Perinatal parameters appear to differ in some aspects according to how the birth centres were labelled. Nevertheless, these differences have only little clinical significance and may be explained by the demographic characteristics of the population. These results do not allow the general conclusion that the quality of out-of-hospital care in Germany differs in relation to the annual birth rates of the birth centres.

Birthing Centers↗

[German-speaking midwifes prefer vaginal mode of delivery to elective Caesarean].

Increasing ceasarean section rates are a world wide concern in obstetrics. One of the latest contributing factors is the elective caesarean section in uncomplicated singleton pregnancy at term. The preference for this mode of delivery was primarily brought forward by obstetric practitioners (Al Mufty, McCarthy, Fisk 1996). A questionnaire, which mainly aimed to ask germanspeaking midwifes in Austria, Germany and Switzerland about their personal choice of delivery mode, was included in one of the issues of the German-language midwifery journal "Die Hebamme". This questionnaire contained 5 half-closed/half open questions describing specific obstetric occurrences. The midwifes were asked to express their preferred mode of delivery and describe their reason for choosing. 446 questionnaires (12 %) were returned. The majority (100 %) of the german speaking midwifes preferred a normal vaginal delivery in an uncomplicated singleton pregnancy at term with a child in cephalic presentation. The rating was about the same (97 %) in the presence of general risk factors which don't indicate a primary caesarean section. Breech presentation and macrosomia are a matter of concern to the midwifes. Midwifes arguing for a first child in breech presentation or with macrosomia > 4.5 kg vote highly significantly more frequently for elective caesarean section than midwifes arguing for at least the second child. The first-rate reasons for the preference of vaginal delivery concern the natural and physiological way of delivery, the personal experience of delivery, the higher risks of caesarean section and the possibility of a later caesarean section in case of fetal distress during first or second stage of labour. Concerns are expressed about the maintenance of competence amongst practitioners, thus influencing the choice of mode of delivery in obstetrics.

Attitude of Health Personnel↗

Intrapartum fetal heart rate monitoring: do Swiss midwives implement evidence into practice?

OBJECTIVE: Evidence Based Medicine has shown that the results of continuous electronic fetal heart rate (FHR) monitoring are equivalent to those of intermittent auscultation. We were interested in the method midwives preferred to use to monitor FHR during labour and the factors which influenced their choice of method. STUDY DESIGN: A questionnaire with Likert scaled questions was sent to 500 German speaking Swiss midwives. Data analysis was performed by using SPSS for Windows. RESULTS: The majority of the midwives were confident monitoring FHR using intermittent auscultation as their main method during low risk delivery. The essential factors influencing the choice of method of FHR monitoring were their own personal experience and hospital guidelines. Less important were factors such as risk category, litigation, the mother's preferences, research results, time and staffing levels. CONCLUSIONS: Although the skills necessary to implement evidence into obstetrical practice are still available, evidence based research results do not seem to be of great importance, when midwives decide which method to use for intrapartum FHR monitoring. Hospital policies and the professional training received were more important factors. Programs designed to implement evidence in care should reflect the identification and use of these factors in order to facilitate the process of realisation.

Evidence-Based Medicine↗

Effects of functional ability and training on chair-rise biomechanics in older adults.

BACKGROUND: Difficulty in rising from a chair is common in older adults and may be assessed by examining the biomechanics of the rise. The purposes of this study were (i) to analyze the biomechanics of rise performance during chair-rise tasks with varying task demand in older adults with varying rise ability and (ii) to determine whether a strength-training program might improve chair-rise success and alter chair-rise biomechanics, particularly under situations of increased task demand. METHODS: A training group (n = 16; mean age, 82 years) completed a 12-week strength-training regimen while a control group (n = 14; mean age, 84 years) participated in a seated flexibility program. Outcomes included the ability to complete seven chair-rise tasks, and, if the chair-rise tasks were successful, the biomechanics of these rises. Chair-rise task demand was increased by lowering the seat height, restricting the use of hands, increasing rise speed, and limiting foot support. RESULTS: At baseline, increased chair-rise task demand generally required increased task completion time, increased anterior center of pressure (COP) placement, increased momentum, increased hip flexion, and increased hip and knee torque output. Those unable to rise at 100% knee height without the use of their hands (task NH-100), compared with those able to rise during task NH-100, followed this pattern in requiring increased time, more anterior placement of the COP, and increased hip flexion to rise in the least demanding tasks allowing the use of hands. However, the unable subjects generated less momentum and knee torque in these tasks. At 12 weeks, and compared with baseline and controls, the training group demonstrated changes in chair-rise biomechanics but no significant changes in rise success. The training subjects, as compared with the controls, maintained a more posterior COP, increased their vertical and horizontal momentum, maintained their knees in greater extension, and maintained their knee-torque output. CONCLUSIONS: These data demonstrate that subtle yet significant changes can be demonstrated in chair-rise performance as a result of a controlled resistance-training program. These biomechanical changes may represent a shift away from impairment in chair-rise ability, and, although the changes are small, they represent how training may reduce rise difficulty.

Aged↗

Locomotor advantages of Neandertal skeletal morphology at the knee and ankle.

We quantified Neandertal knee extensor and ankle plantarflexor moments to determine whether differences between Neandertal and recent human skeletal morphology represent important functional differences. Neandertal skeletal differences in the patella, tibial tuberosity, and calcaneus were used to modify a computer model of recent humans to calculate the moment arms and moments of Neandertal knee extensor and ankle plantarflexor muscles. We also conducted sensitivity studies on the effect of musculotendon parameters on the Neandertal moments. As expected, we found that Neandertal moment arms were greater than recent humans at the ankle (122-141%); however, the magnitude of the increase was not well-predicted from measurements of size differences between Neandertal and recent human skeletons. At the knee, Neandertal moment arms were greater than those of recent humans in the locomotor range (108%) but less so at more flexed knee angles (102%). Not all Neandertal skeletal adaptations at the knee contributed to increased moment arm. Knee extensor moments were enhanced in the Neandertal models in the locomotor range (111%), regardless of musculotendon parameters. At the ankle, however, Neandertal plantarflexor moment was greater than that of recent humans (149-200%) at all joint angles only if muscle fiber length increased proportionately with moment arm. Our results demonstrate that Neandertal skeletal morphology, compared to that of recent humans, generated greater moments at both the knee and ankle in the locomotor range but not at higher angles of knee flexion or ankle plantarflexion.

Animals↗

A comparison of three-dimensional and two-dimensional analyses of facial motion.

The purpose of this study was to compare the amplitude of facial motion obtained using three-dimensional (3-D) and two-dimensional (2-D) methods. The amplitude of motion of fifteen facial landmarks during five maximal animations (smile, lip-purse, grimace, eye closure, and cheek-puff) was quantified in 3-D and 2-D using a video-based system. Results showed that the 3-D amplitudes were significantly larger than the 2-D amplitudes, especially for landmarks on the lower face during the smile animation. In the latter instance, the 2-D amplitudes underestimated the 3-D amplitudes by as much as 43%. The difference between 3-D and 2-D amplitudes was greater for 2-D amplitudes obtained from one camera rather than from multiple cameras. The results suggest that a 2-D analysis may not be adequate to assess facial motion during maximal animations, and that a 3-D analysis may be more appropriate for detecting clinical differences in facial function.

Adult↗

Reliability of a three-dimensional method for measuring facial animation: a case report.

Reliable methods of quantifying functional impairment of the craniofacial region are sorely lacking. The purpose of this study was to test the reliability of a three-dimensional method for assessing the functional repertoire of the face. Subjects were instructed to perform repeated sequences of five maximal facial animations. Facial motions were captured by three 60-Hz video cameras, and three-dimensional maximum motion amplitudes were calculated. Student's t-test and Pearson product-moment correlation coefficients were used to test for significant differences between repetitions. The results show moderate to excellent reliability of the amplitude of motion for the landmarks over all animations. For each specific animation, certain landmarks demonstrated excellent reliability of motion.

Adult↗

Effect of retroviral integration on control of expression of a tumor marker in HeLa cells.

Fusion between HeLa cells and normal human fibroblasts results in the suppression of tumorigenicity. Under prolonged culture conditions, rare tumorigenic segregants arise and have been shown to reexpress a cell surface antigen, p75, which is also present in the HeLa parent but not in the fibroblast parent or in the nontumorigenic HeLa x fibroblast hybrid. Expression of p75 strictly correlates with tumorigenicity in HeLa and human somatic cell hybrids, as has been shown by chromosomal segregation and after gamma-irradiation. Using insertional mutagenesis, we induced expression of p75 in the nontumorigenic hybrid. Three cell clones were isolated that expressed p75 at different levels. Two of these clones exhibited a high level of p75 expression and displayed an altered morphology similar to that of the previously characterized tumorigenic segregants and consistent with the appearance of tumorigenicity. When injected into athymic nude mice, two clones were found to be tumorigenic, one from the onset of subculturing and the second only after further propagation for approximately 50 population doublings. The third clone showed very low p75 expression, had no altered morphology, and was nontumorigenic.

Alkaline Phosphatase↗