PubMed Health⌕ Search

Biomedical subjects

M M Platts

Publications and source records attributed to M M Platts.

At least 19 recordsLinked to original sources

Anaphylactoid reactions during haemodialysis are due to ethylene oxide hypersensitivity.

Anaphylactoid reactions during haemodialysis are unusual, but increasingly recognised. It has recently been reported that there is a significant association between such reactions and the presence of IgE to albumin exposed to ethylene oxide (ETO). Review of the clinical features and epidemiology of dialysis anaphylaxis in the light of this new data suggests that these reactions are due to ETO hypersensitivity.

Anaphylaxis↗

Spleen size in chronic renal failure.

To investigate the cause of clinically detectable splenomegaly, which is common in patients receiving regular haemodialysis, splenic volume was assessed by isotopic scanning using intravenously injected technetium-99m microspheres in 34 controls and 149 patients with chronic renal failure. Of the patients, 16 had never received dialysis, 10 were undergoing continuous peritoneal dialysis, 94 were undergoing regular haemodialysis, and 29 had undergone successful renal transplantation more than nine months previously. Mean splenic volume was increased only in the patients who were receiving haemodialysis. Splenic enlargement was probably not due to iron overload as it occurred in all patients who had received haemodialysis, 14 of whom had not received intravenous iron. No patient had had hepatitis. Splenic enlargement was probably related to the process of haemodialysis itself and may have been due either to red cell damage produced by haemodialysis or to an immunological reaction induced by a component of haemodialysis, possibly ethylene oxide.

Female↗

Water purification and the incidence of fractures in patients receiving home haemodialysis supervised by a single centre: evidence for "safe" upper limit of aluminium in water.

Between 1968 and 1980 fractures occurred in 56 of 284 patients treated by home haemodialysis in the Sheffield area for longer than one year. Patients sustained four times as many fractures while using dialysate prepared with water containing more than 1.0 mumol aluminium per 1 (2.7 micrograms/100 ml) than while using water containing a smaller concentration. When aluminium was removed from water by deionisation the incidence of fractures diminished during the next year and no patient developed dialysis encephalopathy. These findings show that 1.0 mumol/l is a safe maximum concentration of aluminium in water for use in home haemodialysis. It can be detected by the colorimetric aluminium analyses used by many water authorities. When financial resources are limited it is expedient to reserve aluminium analyses by electrothermal atomic absorption for plasma from patients receiving regular haemodialysis. Ingestion of aluminium hydroxide contributes significantly to the increased plasma aluminium concentration of these patients.

Aluminum↗

Impact of continuous ambulatory peritoneal dialysis on treatment of renal failure in patients aged over 60.

Thirty eight patients aged over 60 with end stage renal disease were treated by continuous ambulatory peritoneal dialysis for up to three years. Most of these patients, because of their age or coexisting diseases, had been considered to be unsuitable for haemodialysis by the criteria used before the advent of continuous ambulatory peritoneal dialysis in 1980. Actuarial patient survival at one and two years was 72% and 61% respectively, and only two patients were permanently transferred to haemodialysis. Twenty one of the 23 survivors were fully rehabilitated, the remaining two being partially disabled but living at home. Continuous ambulatory peritoneal dialysis permits more liberal selection of patients with end stage renal disease for renal replacement treatment with excellent survival and rehabilitation and without overburdening scarce hospital haemodialysis facilities.

Aged↗

IgE against ethylene oxide-altered human serum albumin in patients who have had acute dialysis reactions.

Serum samples obtained from seven hemodialysis patients with immediate-type allergic reactions, from six hemodialysis patients without reactions, and from three nonatopic control subjects were analyzed for IgE against human serum albumin exposed to ethylene oxide (ETO-HSA). ETO is used to sterilize medical equipment like dialyzers that cannot withstand heat sterilization. IgE to ETO-HSA, measured by a polystyrene tube technique was found in six of seven dialysis reactor patients but in only one of six nonreactor patients (p less than 0.05 two-tailed Fisher's exact test). No control sera from three nonatopic individuals had antibody. The reactor patients had 2.0 +/- 8.0 ng (SD) of ETO-HSA bound per milliliter of serum, whereas nonreactor patients had 0.2 +/- 8.0 ng per milliliter bound (p less than 0.05 one-tailed Student's t test on log transformed values). We suggest that there is an association between the presence of IgE to ETO-HSA and immediate-type allergic reactions to dialysis in this group of patients.

Antibody Specificity↗

Splenic siderosis and parenteral iron dextran in maintenance haemodialysis patients.

The histological features of 40 spleens surgically removed from maintenance haemodialysis patients are reported. Twenty-four of the 40 (60%) showed massive iron loading and a significant direct correlation was found between iron loading and the amount of intravenous iron dextran administered. Since parenteral iron dextran appears to be a major factor in causing iron overload in haemodialysis patients its use as a method of iron replacement in these patients would appear inappropriate.

Blood Transfusion↗

Genital oedema in patients treated by continuous ambulatory peritoneal dialysis: an unusual presentation of inguinal hernia.

Four patients receiving continuous ambulatory peritoneal dialysis presented with scrotal or labial oedema but no detectable cough impulse. Two of the patients later developed clinical evidence of inguinal hernia, and in the other two inguinal hernias were found at operation. These cases suggest that genital oedema occurring in a patient receiving continuous ambulatory peritoneal dialysis is a sign of a small inguinal hernia which may not be detectable clinically.

Adult↗

Anaphylactoid reactions due to haemodialysis, haemofiltration, or membrane plasma separation.

A previously undescribed anaphylactoid reaction to haemodialysis, haemofiltration, or membrane plasma separation occurred in 15 patients receiving regular dialysis. The illness varied in severity from urticaria, sneezing, and watering of the eyes to severe bronchospasm and cardiovascular collapse, and began within a minute of blood being returned from the dialyser or filtration device to the patient. Reactions developed only when a dialyser sterilised with ethylene oxide was used for the first time and never after sterilisation with formalin. Several patients had more than one reaction while three had a reaction each time a new dialyser was used. Incorrect priming of the dialysers may be a partial explanation of these attacks, but the exact reason for their occurrence is unknown. This is a dramatic and potentially life-threatening syndrome that may not previously have been recognised as a reaction to dialysis.

Anaphylaxis↗

The role of vitamin D metabolites in the osteomalacia of renal disease.

Osteomalacia is commonly found in patients with severe renal impairment. Its aetiology is multifactional and not simply due to deficient production of active metabolites of vitamin D. Decreased availability of calcium and phosphate and the accumulation of aluminium is some dialysis-treated patients are also important aetiological factors. The treatment of osteomalacia depends, in part, upon its accurate diagnosis, and identifying and reversing the underlying cause.

Calcium↗

Dialysis encephalopathy: precipitating factors and improvement in prognosis.

The course of typical dialysis encephalopathy (D.E.) in 12 patients is described. Five patients are still alive from 31 to 57 months after the onset of the disease. Their mental state has improved, but 3 have severe, residual paraplegia. Improvement was associated with the presence of a well functioning renal transplant or dialysis with deionized water. Only one case has developed since deionization of water containing more than 50/micrograms/l of aluminium has been routine. The patients' histories suggest that immobilization, surgery, administration of corticosteroids and hypophosphatemia, all of which induce a negative calcium balance, may release aluminium or another toxic substance from bone and precipitate the onset of D.E.

Alkaline Phosphatase↗

Composition of the domestic water supply and the incidence of fractures and encephalopathy in patients on home dialysis.

Of the 202 patients undergoing home dialysis in the Trent region, 11 developed dialysis encephalopathy, 21 suffered spontaneous fractures, and 36 who had undergone dialysis for over four years had neither of these complications. Because the incidence of complications seemed to be unevenly distributed the water supplies were analysed. Water supplied to the homes of the patients with fractures or encephalopathy contained significantly less calcium and fluorine and significantly more aluminium and manganese than that piped to patients without these complications. The high aluminium concentrations in the bone of patients with encephalopathy was confirmed, but aluminium concentrations in the brains from three patients with encephalopathy were not increased. Patients who undergo dialysis in areas where water contains high aluminium concentrations should be supplied with deionisers.

Aluminum↗

Long-term haemodialysis and thyroid function.

Several indices of thyroid function were assessed in 74 patients with chronic renal failure. Sixty patients had undergone haemodialysis for varying periods. Within the first six months of haemodialysis treatment protein-bound iodine and total thyroxine (T4) levels rose, but after this T4 levels and the free thyroxine index fell progressively. Three out of the 12 patients who had undergone haemodialysis for longer than three years had subnormal T4 and supranormal thyrotrophin concentrations and a subnormal response to thyrotrophin stimulation. Lon-term haemodialysis may be a cause of biochemical hypothyroidism.

Humans↗