Efficacy and safety of tenecteplase in combination with the low-molecular-weight heparin enoxaparin or unfractionated heparin in the prehospital setting: the Assessment of the Safety and Efficacy of a New Thrombolytic Regimen (ASSENT)-3 PLUS randomized trial in acute myocardial infarction.

BACKGROUND: The combination of a single-bolus fibrinolytic and a low-molecular-weight heparin may facilitate prehospital reperfusion and further improve clinical outcome in patients with ST-elevation myocardial infarction. METHODS AND RESULTS: In the prehospital setting, 1639 patients with ST-elevation myocardial infarction were randomly assigned to treatment with tenecteplase and either (1) intravenous bolus of 30 mg enoxaparin (ENOX) followed by 1 mg/kg subcutaneously BID for a maximum of 7 days or (2) weight-adjusted unfractionated heparin (UFH) for 48 hours. The median treatment delay was 115 minutes after symptom onset (53% within 2 hours). ENOX tended to reduce the composite of 30-day mortality or in-hospital reinfarction, or in-hospital refractory ischemia to 14.2% versus 17.4% for UFH (P=0.080), although there was no difference for this composite end point plus in-hospital intracranial hemorrhage or major bleeding (18.3% versus 20.3%, P=0.30). Correspondingly, there were reductions in in-hospital reinfarction (3.5% versus 5.8%, P=0.028) and refractory ischemia (4.4% versus 6.5%, P=0.067) but increases in total stroke (2.9% versus 1.3%, P=0.026) and intracranial hemorrhage (2.20% versus 0.97%, P=0.047). The increase in intracranial hemorrhage was seen in patients >75 years of age. CONCLUSIONS: Prehospital fibrinolysis allows 53% of patients to receive reperfusion treatment within 2 hours after symptom onset. The combination of tenecteplase with ENOX reduces early ischemic events, but lower doses of ENOX need to be tested in elderly patients. At present, therefore, tenecteplase and UFH are recommended as the routine pharmacological reperfusion treatment in the prehospital setting.

Aged↗

Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography.

AIMS: We studied the capability of heart rate (HR) adjusted change in multichannel magnetocardiogram (MCG) to detect exercise-induced ischemia. METHODS AND RESULTS: The MCG and 12-lead ECG were recorded simultaneously during supine exercise testing in 17 healthy controls and 24 patients with single vessel coronary artery disease (CAD). In the MCG analysis, we plotted the orientation of the magnetic field map (MFM) against the HR in each cardiac cycle during recovery. A regression line was fitted to the data and the line slope (degrees/bpm) was determined. In the ECG, the ST-segment depression vs HR (ST/HR) slope was evaluated. The HR adjusted MFM rotation was more extensive in the pooled CAD group, and in all subgroups with different stenosed vessel, than in the control group at the ST-segment (1.5 +/- 2.1 degrees/bpm vs 0.29 +/- 0.25 degrees/bpm, p < 0.0005) and at the T-wave apex (0.95 +/- 0.81 degrees/bpm vs 0.24 +/- 0.25 degrees/bpm, p < 0.0005). Areas under the receiver operating characteristic curves of the HR adjusted MFM rotation at the ST-segment (88.5%) and the T-wave (86.0%) were higher than the ones without HR adjustment (75.5% and 68.1%, respectively), and higher than the area of ST/HR slope in the ECG (80.2%). CONCLUSION: HR adjusted MFM rotation detects transient ischemia independent of the stenosed vessel. HR adjustment improves the performance of the MCG in ischemia detection by the analysis of the ST-segment and the T-wave. The MCG was superior to the 12-lead ECG.

Aged↗

ST-segment level and slope in exercise-induced myocardial ischemia evaluated with body surface potential mapping.

Body surface potential mapping (BSPM) is superior to 12-lead electrocardiography for detection of acute and old myocardial infarctions (MIs). We used BSPM to examine electrocardiographic criteria for acute reversible myocardial ischemia. BSPM with 123 channels was performed in 45 patients with coronary artery disease (CAD) and 25 healthy controls during supine bicycle exercise testing. Of the 45 patients, 18 patients had anterior, 14 had posterior, and 13 had inferior ischemia documented by coronary angiography and thallium scintigraphy. The ST amplitude was measured 60 ms after the J-point and the ST slope calculated by fitting a regression line from the J-point to 60 ms after it. The optimal locations for detecting ST depression and ST-slope decrease were identified. In the pooled CAD patient group, the optimal location for ST depression was 5 cm below standard lead V(5) (CAD group: -70 +/- 70 microV; controls: 70 +/- 80 microV, p <0.001). Using a cut-off value of -10 microV, the ST depression separated the patients with CAD from controls with a sensitivity of 84% and a specificity of 96%. The ST slope became more horizontal in the patient group than in the control group. The optimal location for ST-slope decrease was over the left side (CAD group: 20 +/- 20 microV/s; controls: 720 +/- 320 microV/s, p <0.001). Using a cut-off value of 320 microV/s, the ST slope separated patients with CAD from controls with a sensitivity of 93% at a specificity level of 88%. The area under the receiver operating characteristic curve of ST slope tended to be higher than the one of ST depression (97% vs 93%; p = 0.097). In conclusion, regions sensitive for ST depression and for ST-slope decrease could be identified in BSPM, despite variation in the location of ischemia and the presence or absence of a history of MI. ST slope is a sensitive and specific marker of transient myocardial ischemia, and might perform even better than ST depression.

Body Surface Potential Mapping↗

Recording locations in multichannel magnetocardiography and body surface potential mapping sensitive for regional exercise-induced myocardial ischemia.

INTRODUCTION: This study aimed to identify the optimal locations in multichannel magnetocardiography (MCG) and body surface potential mapping (BSPM) to detect exercise-induced myocardial ischemia. METHODS: We studied 17 healthy controls and 24 coronary artery disease (CAD) patients with stenosis in one of the main coronary artery branches: left anterior descending (LAD) in 11 patients, right (RCA) in 7 patients, and left circumflex (LCX) in 6 patients. MCG and BSPM signals were recorded during a supine bicycle stress test. The capability of a recording location to separate the groups was quantified by subtracting the mean signal amplitude of the normal group from that of the patient group during the ST segment and at the T-wave apex, and dividing the resulting amplitude difference by the corresponding standard deviation within all subjects. RESULTS: In MCG the optimal location for ST depression was at the right inferior grid for the RCA, at the mid-inferior grid for the LCX, and in the middle of these locations for the LAD subgroup (mean ST amplitudes: CAD -80 +/- 360fT, controls 610 +/- 660fT; p < 0.001). In BSPM it was on the left upper anterior thorax for the LAD, left lower anterior thorax for the RCA, and on the lower back for the LCX subgroup (mean ST amplitudes: CAD -39 +/- 61 microV and controls 38 +/- 38 microV; p < 0.001). In MCG the optimal site for T-wave amplitude decrease was the same as the one for the ST depression. In BSPM it was on the middle front for the LAD, on the back for the LCX and on the left abdominal area for the RCA group. In accordance with electromagnetic theory, the largest ST segment and T-wave amplitude changes took place in MCG in locations orthogonal to those in BSPM. CONCLUSION: This study identified magnetocardiographic and BSPM recording locations which are sensitive for detecting transient myocardial ischemia by evaluation of the ST segment as well as the T-wave. These locations strongly depend on ischemic regions and are outside the conventional 12-lead ECG recording sites.

Aged↗

Magnetocardiographic intra-QRS fragmentation analysis in the identification of patients with sustained ventricular tachycardia after myocardial infarction.

The aim of this study was to investigate if magnetocardiographic (MCG) analysis of cardiac micropotentials within the QRS complex can identity patients prone to ventricular arrhythmias, and to compare it to MCG time-domain, late-field analysis. The study population consisted of 136 patients with remote MI, 53 with and 83 without a history of VT. After averaging and high pass filtering of multichannel MCG signals, time-domain parameters describing the end-QRS activity and fragmentation index M and score S describing the whole QRS complex were computed. Fragmentation and time-domain parameters differed between the VT and control groups: fragmentation index M was 12 +/- 3 versus 9 +/- 2 (P <0.001), fragmentation score S was 83 +/- 42 versus 56 +/- 21 (P < 0.001), and filtered QRS duration was 144 +/- 32 versus 114 +/- 19 ms (P < 0.001) in VT and control groups, respectively. A combination of fragmentation parameters yielded 87% sensitivity and 61% specificity in VT identification. Corresponding figures for a time-domain parameter combination were 81% and 72%. Sensitivity of time-domain analysis was 88% and specificity was 75% in a subgroup with anterior MI. In multivariate analysis, fragmentation and time-domain analyses discriminated VT patients from controls independently of the extent of coronary artery disease or left ventricular dysfunction. MCG in postinfarction patients reveals pathology associated with propensity to ventricular arrhythmias inside and not only at the end of the QRS complex. MCG seems most accurate in the anterior infarct location.

Aged↗

Repolarization abnormalities detected by magnetocardiography in patients with dilated cardiomyopathy and ventricular arrhythmias.

INTRODUCTION: Abnormal repolarization is one of the acknowledged mechanisms leading to malignant ventricular arrhythmias. We used a novel magnetocardiographic technique to investigate the role of inhomogeneous repolarization in patients with nonischemic dilated cardiomyopathy prone to sustained ventricular arrhythmias. METHODS AND RESULTS: Forty-nine dilated cardiomyopathy patients were studied, 18 with a history of sustained ventricular tachycardia (n = 6) or ventricular fibrillation (n = 12) and 31 with no ventricular arrhythmias. The magnetocardiogram was registered and QT apex and QT end intervals were determined by a computer algorithm. Inhomogeneity of repolarization was characterized with indices describing QT apex and QT end dispersion, and T wave end duration. In addition, time-domain late fields of the QRS complex in magnetocardiography and QT dispersion in 12-lead ECG were determined. T wave end was longer in the arrhythmia group in patients with sinus rhythm (87 +/- 15 msec vs 73 +/- 12 msec; P = 0.005) and in those not having bundle branch block. Magnetocardiographic late fields of the QRS complex were not different between groups. QT apex and end dispersion on magnetocardiography or 12-lead ECG showed no difference. CONCLUSION: Prolongation of the end part of the T wave revealed by magnetocardiography is related to malignant ventricular arrhythmias in dilated cardiomyopathy. The results suggest that abnormal repolarization rather than delayed conduction underlies the arrhythmias in this disease.

Adult↗

Postmyocardial infarction patients susceptible to ventricular tachycardia show increased T wave dispersion independent of delayed ventricular conduction.

INTRODUCTION: Experimentally, both delayed ventricular conduction and nonhomogeneous ventricular repolarization contribute to reentrant arrhythmias. We tested the hypothesis that increased T wave dispersion is independent of delayed ventricular conduction associated with arrhythmia vulnerability in postmyocardial infarction (post-MI) patients. METHODS AND RESULTS: We studied 32 post-MI patients with clinical or inducible monomorphic ventricular tachycardia (VT group), 28 post-MI patients without arrhythmias (MI group), and 13 healthy controls, using magnetocardiographic (MCG) mapping with signal averaging. Twelve-lead ECG was the reference. Filtered QRS duration (fQRS) and T wave peak to T wave end interval (TPE) were used as measures of ventricular conduction and nonhomogeneity in ventricular repolarization, respectively. In MCG, the VT group showed the longest fQRS (135+/-34 msec vs 114+/-22 msec in the MI group; P = 0.012). Mean TPE and maximum TPE in VT versus MI groups were 78+/-9 msec versus 70+/-6 msec (P < 0.001) and 117+/-23 msec versus 104+/-19 msec (P = 0.020), respectively. Maximum TPE did not correlate with fQRS in the VT group (r = 0.063; P = NS) but did correlate in the MI group (r = 0.396; P = 0.037). For identification of post-MI patients prone to VT, selection of cutoff values for fQRS >140 msec and mean TPE >81 msec gave sensitivity and specificity of 41% and 89%, and 31% and 96%, respectively. Their combination increased sensitivity to 63% while maintaining 89% specificity. CONCLUSION: Post-MI patients susceptible to VT show increased T wave dispersion independent of delayed ventricular conduction.

Aged↗

Current-density estimation of exercise-induced ischemia in patients with multivessel coronary artery disease.

Magnetocardiographic and body surface potential mapping data measured in 6 patients with multivessel coronary artery disease were used in equivalent current-density estimation (CDE). Patient-specific boundary-element torso models were acquired from magnetic resonance images. Positron emission tomography data registrated with anatomical magnetic resonance imaging data provided the gold standard. Discrete current-density estimation values were computed on the epicardial surface of the left ventricle from difference (stress-rest) ST-segment maps. The ill-posed inverse problem was regularized with 3 different methods (Tikhonov regularization with an identity or a surface Laplacian operator and a maximum a posteriori estimator). Comparisons with positron emission tomography studies showed that the maximum a posteriori estimator is superior to other regularizations, provided that a suitable a priori information is available. In general, good correspondence was found for segments of high and low amplitude in current-density estimations, and the viable and scar areas in positron emission tomography, respectively.

Body Surface Potential Mapping↗

Beat-to-beat analysis method for magnetocardiographic recordings during interventions.

Multichannel magnetocardiography (MCG) during exercise testing has been shown to detect myocardial ischaemia in patients with coronary artery disease. Previous studies on exercise MCG have focused on one or few time intervals during the recovery period and only a fragment of the data available has been utilized. We present a method for beat-to-beat analysis and parametrization of the MCG signal. The method can be used for studying and quantifying the changes induced in the MCG by interventions. We test the method with data recorded in bicycle exercise testing in healthy volunteers and patients with coronary artery disease. Information in all cardiac cycles recorded during the recovery period of exercise MCG testing is, for the first time, utilized in the signal analysis. Exercise-induced myocardial ischaemia was detected by heart rate adjustment of change in magnetic field map orientation. In addition to the ST segment, the T wave in the MCG was also found to provide information related to myocardial ischaemia. The method of analysis efficiently utilizes the spatial and temporal properties of multichannel MCG mapping, providing a new tool for detecting and quantifying fast phenomena during interventional MCG studies. The method can also be applied to an on-line analysis of MCG data.

Coronary Disease↗

Magnetocardiographic and electrocardiographic exercise mapping in healthy subjects.

In 12-lead electrocardiography (ECG), detection of myocardial ischemia is based on ST-segment changes in exercise testing. Magnetocardiography (MCG) is a complementary method to the ECG for a noninvasive study of the electric activity of the heart. In the MCG, ST-segment changes due to stress have also been found in healthy subjects. To further study the normal response to exercise, we performed MCG mappings in 12 healthy volunteers during supine bicycle ergometry. We also recorded body surface potential mapping (BSPM) with 123 channels using the same protocol. In this paper we compare, for the first time, multichannel MCG recorded in bicycle exercise testing with BSPM over the whole thorax in middle-aged healthy subjects. We quantified changes induced by the exercise in the MCG and BSPM with parameters based on signal amplitude, and correlation between signal distributions at rest and after exercise. At the ST-segment and T-wave apex, the exercise induced a magnetic field component outward the precordium and the minimum value of the MCG signal over the mapped area was found to be amplified. The response to exercise was smaller in the BSPM than in the MCG. A negative component in the MCG signal at the repolarization period of the cardiac cycle should be considered as a normal response to exercise. Therefore, maximum ST-segment depression over the mapped area in the MCG may not be an eligible parameter when evaluating the presence of ischemia.

Biomedical Engineering↗

Identification of post-myocardial infarction patients with ventricular tachycardia by time-domain intra-QRS analysis of signal-averaged electrocardiogram and magnetocardiogram.

A new time-domain analysis method, which quantifies ECG/MCG intra-QRS fragmentation, is applied to parts of the QRS complex to identify post-myocardial infarction patients with ventricular tachycardia. Three leads of signal-averaged electrocardiograms and nine leads of magnetocardiograms were band-pass filtered (74 Hz to 180 Hz). The filtered signals showed fragmentation in the QRS region, which was quantified by the number of peaks M and a score S, that is the product of M and the sum of the peak amplitudes. Both parameters were determined for the first 80 ms of the QRS complex and the total QRS complex in each channel. For classification, the mean-values of the parameters M and S of the three electrical leads and the nine magnetic leads were calculated. Late potential and late field analyses were performed for the same signals. 31 myocardial infarction patients were included, 20 of them with a history of documented ventricular tachycardia (VT). Identification of VT patients using the SAECG led to better results (sensitivity 95%, specificity 91%) considering the entire QRS complex than with the standard late potential analysis suggested by Simson (sensitivity 90%, specificity 73%). For the SAMCG and the entire QRS complex results using the parameters S and M are also better (sensitivity 95%, specificity 100%) than for the late field analysis (sensitivity 90% and specificity 100%). For the first 80 ms, the performance of the parameters M and S is only slightly decreased.

Adult↗

Magnetocardiographic QT dispersion during cardiovascular autonomic function tests.

QT dispersion is considered to reflect nonhomogeneity of ventricular repolarization. The autonomic nervous system modulates QT interval duration, but the effect may not be spatially homogenous. Magnetocardiography (MCG) registers the weak magnetic fields generated by myocardial electric currents with high localizing accuracy. We studied the effects of rapid cardiovascular autonomic nervous adjustment on QT dispersion in MCG. Ten healthy male volunteers were monitored during deep breathing, the Valsalva maneuver, sustained handgrip, hyperventilation, the cold pressor test and mental stress. 67 MCG channels and 12 ECG leads were recorded simultaneously. A computer algorithm was used for QT interval measurements. QT dispersion was defined as maximum - minimum or standard deviation of the QTpeak and QTend intervals. In MCG the QT(end) dispersion increased during deep inspiration compared with deep expiration (96+/-19 ms v. 73+/-27 ms, p = 0.05). Magnetic QT dispersion tended to increase during the bradycardia phase of the Valsalva maneuver, but the change was obvious only for QT(end) (55+/-26 ms v. 76+/-29 ms, p<0.05). Other tests had no significant effect on QT dispersion, not even the cold pressor test, although it causes strong sympathetic activation. Magnetic and electric QT(peak) and QT(end) intervals correlated closely (r = 0.93 and 0.91), whereas the QT dispersion measures showed no correlation. In conclusion, magnetic QT dispersion is not modified by rapid changes in autonomic tone, but maneuvers involving deep respiratory efforts and changes in ventricular loading affect QT dispersion measurements.

Adult↗

Effects of cardiovascular autonomic function tests on QT dispersion in the 12-lead electrocardiogram of healthy patients.

Changes in autonomic tone modulate QT interval duration. How cardiovascular autonomic reflexes affect QT dispersion, a suggested marker of arrhythmia risk, is not well established. We studied 10 healthy young adult volunteer men during quiet and deep breathing, the Valsalva maneuver, sustained handgrip, hyperventilation, the cold pressor test, and mental stress. An automated method was used for measurement of QT-peak and QT-end intervals, and QT dispersion was defined as maximum-minimum of the measured intervals. QT-peak dispersion was greater on deep expiration than deep inspiration (49 +/- 20 ms vs 37 +/- 14 ms, P < .05). QT-end dispersion decreased in the tachycardia phase of the Valsalva maneuver (45 +/- 23 ms vs 35 +/- 21 ms, P < .05), but QT dispersion did not change during the other interventions. Rapid cardiovascular autonomic reflex adjustment does not change QT dispersion in healthy young adult men. However, large intrathoracic volume and intrathoracic pressure changes during forced respiratory movements might confound QT dispersion measurements.

Adult↗

Late fields of the magnetocardiographic QRS complex as indicators of propensity to sustained ventricular tachycardia after myocardial infarction.

INTRODUCTION: Magnetocardiographic (MCG) mapping is a new method to record cardiac signals. This study examined the association of MCG late fields with the propensity to sustained ventricular tachycardia (VT) after myocardial infarction (MI). METHODS AND RESULTS: One hundred patients with remote MI were studied, 38 with and 62 without history of VT. High-resolution MCG and signal-averaged ECG (SAECG) as a comparative method were recorded. Time-domain parameters describing the abnormal low-amplitude end QRS activity, MCG late fields, and SAECG late potentials were analyzed. Late field parameters differed significantly between the patient groups: filtered QRS duration was 137 +/- 26 msec in the VT group and 110 +/- 18 msec in the control group (P < 0.001), and root mean square amplitude of the last 40 msec was 260 +/- 170 and 510 +/- 360 fT (P < 0.001), respectively. The optimal MCG parameter combination yielded a sensitivity of 92% and a specificity of 61% in classification to the VT group, whereas those for SAECG were 63% and 66%. In a subgroup of 63 patients with marked left ventricular dysfunction and comparable stage of coronary heart disease, only MCG (sensitivity 73%, specificity 67%) but not SAECG could assign a patient to the VT group. CONCLUSION: Late fields of the MCG QRS complex indicate propensity to life-threatening arrhythmias in post-MI patients. This discriminative ability persists in the presence of severe left ventricular dysfunction where ECG late potentials lose their informative value. MCG late field analysis is a potential new method for noninvasive risk assessment in post-MI patients.

Electrocardiography↗

Bioelectromagnetic localization of a pacing catheter in the heart.

The accuracy of localizing source currents within the human heart by non-invasive magneto- and electrocardiographic methods was investigated in 10 patients. A non-magnetic stimulation catheter inside the heart served as a reference current source. Biplane fluoroscopic imaging with lead ball markers was used to record the catheter position. Simultaneous multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) recordings were performed during catheter pacing. Equivalent current dipole localizations were computed from MCG and BSPM data, employing standard and patient-specific boundary element torso models. Using individual models with the lungs included, the average MCG localization error was 7+/-3 mm, whereas the average BSPM localization error was 25+/-4 mm. In the simplified case of a single homogeneous standard torso model, an average error of 9+/-3 mm was obtained from MCG recordings. The MCG localization accuracies obtained in this study imply that the capability of multichannel MCG to locate dipolar sources is sufficient for clinical purposes, even without constructing individual torso models from x-ray or from magnetic resonance images.

Body Surface Potential Mapping↗

Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography.

This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies.

Adult↗

Autonomic modulation of QT intervals in post-myocardial infarction patients with and without ventricular fibrillation.

The autonomic nervous system plays an important role in the genesis of sudden cardiac death. The aim of this study was to evaluate spatial autonomic QT interval modulation at the myocardial level. Circadian patterns of QT intervals and heart rate variability (HRV) components and their hourly linear correlations were determined by Holter recordings in 15 healthy subjects (controls), in 15 post-myocardial infarction (MI) patients resuscitated from ventricular fibrillation (VF) (VF group), and in 15 matched infarction patients without a history of arrhythmia events (MI group). QT intervals were measured in modified leads V1 and V5 individually at same stable heart rates during each hour and related to hourly measures of HRV. Controls had highly significant correlations between QT intervals and the high-frequency component of HRV (parasympathetic modulation), and between QT intervals and low- to high-frequency ratio (sympathetic modulation) uniformly in both leads (r from 0.62 to 0.81, p <0.001). The MI group had impaired sympathetic modulation in V5 (r = 0.34, p = NS), but had uniform and exaggerated sensitivity to parasympathetic modulation. In the VF group the QT difference between V1 and V5 leads correlated with parasympathetic modulation (r = 0.401, p <0.05) and sympathetic modulation (r = 0.446, p <0.05). Thus, normal subjects exhibit spatially uniform autonomic QT modulation. Myocardial damage can result in abolished, exaggerated, or regionally discordant QT modulation, and this may generate arrhythmic vulnerability.

Adult↗

Magnetocardiographic QT interval dispersion in postmyocardial infarction patients with sustained ventricular tachycardia: validation of automated QT measurements.

QT dispersion is a measure of heterogeneity in ventricular repolarization. Increased ECG QT dispersion is associated with life-threatening ventricular arrhythmias. We studied if magnetocardiographic (MCG) measures of QT dispersion can separate postmyocardial infarction patients with and without susceptibility to sustained VT. Manual dispersion measurements were compared to a newly adapted automatic QT interval analysis method. Ten patients with a history of sustained VT (VT group) and eight patients without ventricular arrhythmias (Controls) were studied after a remote myocardial infarction. Single-channel MCGs were recorded from 42 locations over the frontal chest area and the signals were averaged. QT dispersion was defined as maximum-minimum or standard deviation of measured QT intervals. VT group showed significantly more QT and JT dispersion than Controls. QTapex dispersions were 127 +/- 26 versus 83 +/- 21 ms (P = 0.004) and QTend dispersions 130 +/- 37 versus 82 +/- 37 ms (P = 0.013), respectively. Automatic method gave comparable values. Their relative differences were 9% for QTapex and 27% for QTend dispersion on average. In conclusion, increased MCG QT interval dispersion seems to be associated with a susceptibility to VT in postmyocardial infarction patients. MCG mapping with automated QT interval analysis may provide a user independent method to detect nonhomogeneity in ventricular repolarization.

Algorithms↗