PubMed Health⌕ Search

Biomedical subjects

M Macha

Publications and source records attributed to M Macha.

21 records · Page 2Linked to original sources

Management of the sensitized cardiac recipient: the use of plasmapheresis and intravenous immunoglobulin.

Previously, we reported that the combination of plasmapheresis (PP) and intravenous immunoglobulin (IVIg) allow sensitized patients to undergo orthotopic heart transplantation (OHT), even across a positive crossmatch. In the current study, the effect of that combination, PP+IVIg, on survival of a larger group of such recipients is investigated. The latter group (I) consisted of 35 sensitized patients who received PP+IVIG together with standard immunosuppressive drugs. Rejection was seen in 11 patients, findings strongly suggestive of a vascular (humoral) being identified in five of those cases. Four deaths occurred, two of them in the immediate post-operative period, one after almost six months, and one after almost two yr post-OHT. Follow-up range 4.5 months to 7.8 yr post-OHT (average=1.1 yr). Patient survival was analyzed after generation of a Kaplan-Meier plot. Comparison with a control OHT group (II) given standard immunosuppressive drugs only (N=276) showed enhanced survival of group I (p=0.0414 by log-rank test). We conclude that the combination of PP and IVIG (i) is associated with declines in T- and B-percent-reactive antibody and in crossmatch positivity, and (ii) is very useful in the management of the sensitized cardiac patient undergoing OHT, often allowing a successful outcome to transplantation in the face of a positive crossmatch.

Biopsy↗

In vivo evaluation of an extracorporeal pediatric centrifugal blood pump.

This paper summarizes the authors' in vivo experience in evaluating a miniature centrifugal blood pump designed for pediatric/neonatal ventricular support. Left ventricular bypass was accomplished in two adult sheep and five juvenile lambs (5.5-80.0 kg) via either central (left ventricle to carotid artery) or peripheral (jugular vein to carotid artery) cannulation. Animals were weaned from mechanical ventilation and continuously monitored. Hemodynamic parameters remained within a normal range over the duration of the bypass. Two of five lambs were electively killed at 8, and 76 hours; the remaining three lambs died from respiratory complications at 33, 44, and 156 hours. There were no mechanical complications, and blood seal integrity was confirmed beyond 6 days. The pump speed was maintained at 3,000-4,500 rpm with pump flow rates between 0.4-1.5 L/min. Average plasma free hemoglobin was below 20 mg/dl in the five lamb experiments. Renal, hepatic, and hematologic indices also remained within physiologic ranges. Histopathologic analyses of major organs revealed renal cortical infarctions in two of five lambs. Examination of the pump surfaces after explant indicated small areas of thrombus in the housing adjacent to the outflow ports in two experiments. These encouraging results support further testing and refinement of this miniature centrifugal pump.

Animals↗

Survival for up to six months in calves supported with an implantable axial flow ventricular assist device.

This paper summarizes the authors' in vivo experience to date with an implantable axial flow blood pump designed for long-term ventricular support. This small, valveless pump with blood-lubricated bearings has been implanted in six calves (83 +/- 6 kg) as a left ventricular assist device (LVAS). The left ventricle and descending thoracic aorta were cannulated by left thoracotomy, and the pump was placed in a subcutaneous pocket below the costal margin. Animals remained hemodynamically stable throughout the course of support during partial left ventricular bypass. Five animals were killed after 15, 27, 52, 57, and 181 days. The longest survivor (181 days) demonstrated normal pump function at the time death. Pump speed was maintained at 10,100 +/- 100 rpm, with an average pump flow rate of 4.9 +/- 0.5 L/min under resting physiologic conditions. Average plasma free hemoglobin was 17.4 +/- 7.5 mg/dl. Renal, hepatic, and hematologic indices remained within physiologic range in all of these animals, except during the immediate postoperative period. Histopathologic analyses of major organs after death revealed small renal cortical infarcts in five of six animals; the remaining organs were normal. These animal studies support the feasibility of this small implanted axial flow pump for long-term ventricular assistance.

Animals↗