PubMed Health⌕ Search

Biomedical subjects

M Mack

Publications and source records attributed to M Mack.

113 records · Page 7Linked to original sources

Medium-chain acyl-CoA dehydrogenase (MCAD) deficiency: the prevalent mutation G985 (K304E) is subject to a strong founder effect from northwestern Europe.

Medium-chain acyl CoA dehydrogenase (MCAD) deficiency is a potentially fatal inherited defect of fatty acid beta-oxidation. Approximately 90% of the disease-causing alleles in diagnosed patients are due to a single base mutation, an A (adenine) to G (guanine) transition at position 985 of MCAD cDNA (G985). In a limited number of cases it was found that this mutation was always associated with a particular haplotype, defined by three intragenic restriction fragment length polymorphisms, indicating a founder effect [Kølvraa et al.; Hum Genet 1991; 87: 425-429]. In addition, recent studies of American patients and their ancestors suggested the existence of a founder from northern Europe [Yokota et al.; Am J Hum Genet 1991; 49: 1280-1291]. In the present study we document (1) that the G985 heterozygous frequency in the Caucasian population of North Carolina in the USA is 1/84, which is 5- to 10-fold higher than in non-Caucasian Americans; (2) that there exists a 100% association of the G985 mutation in 17 families with MCAD-deficient patients to a certain haplotype, defined by the restriction endonucleases BanII, PstI and TaqI; (3) that MCAD deficiency due to the G985 mutation is more frequent in the Netherlands, Ireland, England, Belgium and Denmark than in other western European countries, and (4) that the frequency distribution of G985 mutation carriers is 1/68-1/101 in newborns in the United Kingdom and Denmark, and 1/333 in Italy. These results support the notion of a founder effect in northwestern Europe.

Acyl-CoA Dehydrogenase↗

LIAISON hCG--an automated chemiluminescent immunoassay for the determination of human chorionic gonadotropin (hCG).

An immunoassay utilizing chemiluminescence and paramagnetic particles has been developed for the new fully automated, random access LIAISON immunoanalyzer. The LIAISON hCG assay is a two-site immunolouminometric one-step assay using two highly specific monoclonal antibodies. Total incubation time is only 10 min. A specially designed unique Reagent Integral contains all specific reagents; the on-board stability of these reagents is given over a very long period (> 4 weeks). The assay works with a 2-point calibrated master curve. 30 microliters sample is added to 200 microliters tracer and 20 microliters antibody-coated magnetic particles. After 10 min incubation the particles are separated, washed and the chemiluminescent signal is generated. The time to first result is only 15 min. The assay with a unique extended standard range up to 5,000 ng/ml shows no high dose hook effect up to 500,000 mlU/ml (spiked sera). The assay detects both the intact molecule and the free beta subunit. The cross-reactivity to FSH, LH and TSH is less than 0.1%. Precision (within-run < 3%; between-run < 5%), linearity, recovery and sensitivity (< 0.5 mlU/ml) are excellent. The assay shows a very good correlation to the LIA-mat hCG (r = 0.996). In summary the LIAISON hCG assay together with the new LIAISON immunoanalyzer is a very rapid and accurate method for the quantitative determination of hCG/beta-hCG in serum.

Antibodies, Monoclonal↗

LIAISON Ferritin--an automated chemiluminescent immunoassay for the determination of Ferritin.

An immunoassay utilizing chemiluminescence and paramagnetic particles has been developed for the new fully automated random access LIAISON immunoanalyzer. The LIAISON Ferritin assay is a two-site immunoluminometric one-step assay using two highly specific monoclonal antibodies. A specially designed unique Reagent Integral contains all specific reagents. The cooled reagent compartment guarantees an on-board stability of at least 4 weeks. The assay works with a 2-point calibrated master curve. To perform, the assay, 10 microliters sample is added to 300 microliters tracer and 20 microliters antibody-coated magnetic particles. After 10 min incubation the particles are separated, washed and the chemiluminescent signal is generated. The time to first result is only 15 min. The assay with a unique extended standard range up to 3,000 ng/ml shows no high dose hook effect up to 150,000 ng/ml (spiked sera). The cross-reactivity to human liver ferritin is 100%, to human spleen ferritin 66% and to human heart ferritin 8%. Precision (within-run < 3%; between-run < 5%), linearity, recovery and sensitivity (< 0.2 ng/ml) are excellent. The assay shows a very good correlation to LlA-mat Ferritin (r = 0.994). In summary the LIAISON Ferritin run on the new LIAISON immunoanalyzer and is a very rapid and accurate method rapidly providing reliable results.

Autoanalysis↗

Thoracoscopic approach for the pericardium.

The technique of video-assisted thoracic surgery (VATS) offers a new approach for management of effusive diseases of the pericardium. By the thoracoscopic approach, which can be performed through either the right or left chest cavity, an extensive pericardiectomy equivalent to one performed through a thoracotomy can be performed. Patients with benign effusive pericarditis, malignant pericardial effusions with a good prognosis, post-radiation pericarditis, purulent pericarditis, and delayed tamponade after open cardiac procedures can be optimally managed by video-assisted techniques.

Equipment Design↗