[Modification of the detection and stimulation behavior of active and passive fixed bipolar pacemaker electrodes by depot dexamethasone].

In a prospective, non-randomised study, two atrial steroid-eluting screw-in leads were evaluated (CapSureFix 4068, Medtronic, n = 17; Accufix II DEC 033-812, Telectronics, n = 16); in the same way, measurements were obtained of three steroid eluting ventricular electrodes (two screw-in leads: CapSureFix 4068, Medtronic, n = 11; Accufix II DEC 033-212, Telectronics, n = 20 and one tined lead Encor DEC 033-448, Telectronics, n = 18). Measurements were performed during implantation (= acute), 7 +/- 3 days after implantation (= subacute) and during follow-up at 3 and 6 months. After atrial implantation, there were no significant differences of the stimulation thresholds (Accufix II DEC: 0.76 +/- 0.23 V-CapSureFix: 0.75 +/- 0.16 V). During follow-up, a slight but not significant increase of the stimulation threshold was observed (Accufix II DEC: subacute 0.99 +/- 0.45 V; 3 months 0.79 +/- 0.43 V; 6 months: 0.84 +/- 0.45 V.-CapSureFix: subacute 0.76 +/- 0.18 V; 3 months 0.87 +/- 0.31 V; 6 months 0.88 +/- 0.32 V). The acute atrial thresholds were significantly lower in the right atrial appendage than in the right lateral wall, while there was no difference during measurements at 3 and 6 months (atrial appendage n = 20 acute 0.69 +/- 0.11 V; right lateral wall n = 13 acute 0.85 +/- 0.25 V). The ventricular Encor DEC and Accufix II DEC electrodes had similar thresholds at implantation, whereas the CapSureFix electrode showed significantly higher stimulation thresholds (Encor DEC 0.56 +/- 0.15 V; Accufix II DEC 0.53 +/- 0.13 V; CapSureFix 0.8 +/- 0.16 V). During follow-up the stimulation threshold increased significantly with each ventricular electrode (Encor DEC: subacute 0.71 +/- 0.22 V; 3 months 0.77 +/- 0.23 V; 6 months 0.8 +/- 0.28 V-Accufix II DEC: subacute 0.86 +/- 0.44 V; 3 months 0.8 +/- 0.25 V; 6 months 0.74 +/- 0.21 V-CapSureFix: subacute 0.92 +/- 0.17 V; 3 months 1.14 +/- 0.46 V; 6 months 1.12 +/- 0.32 V). With regard to the sensing of the intracardiac signals, no differences among the electrodes were detected at the atrial as well as the ventricular level. Subacutely all electrodes had a significant decrease of sensing level without changes after 3 and 6 months (atrium: CapSureFix acute 4.08 +/- 1.34 mV, subacute 3.09 +/- 0.88 mV, 3 months 2.91 +/- 1.02 mV, 6 months 3.0 +/- 1.22 mV; Accufix II DEC acute 4.34 +/- 1.49 mV, subacute 2.86 +/- 1.18 mV, 3 months 3.07 +/- 1.04 mV, 6 months 2.91 +/- 1.16 mV-ventricle: CapSureFix acute 11.55 +/- 4.5 mV, subacute 9.99 +/- 3.51 mV, 3 months 9.36 +/- 3.23 mV, 6 months 9.13 +/- 3.4 mV; Accufix II DEC acute 10.66 +/- 3.0 mV, subacute 7.49 +/- 4.04 mV, 3 months 7.25 +/- 3.64 mV, 6 months 7.52 +/- 4.1 mV; Encor DEC acute 11.65 +/- 3.9 mV, subacute 9.04 +/- 3.29 mV, 3 months 8.69 +/- 3.83 mV, 6 months 8.78 +/- 3.32 mV). The impedance of the Accufix II DEC electrode was significantly lower than the CapSureFix electrode at the time of implantation in the atrium. The ventricular electrodes with active fixation showed a decrease of impedance 7 days after implantation, which diminished during chronic follow-up. On the other hand, the Encor DEC electrode did not exhibit any change of impedance at the different times of determination. In summary, the dexamethasone depots prevented the rise of the stimulation threshold in all the atrial electrodes with active fixation. There remained a small increase of the stimulation threshold after ventricular implantation, which did not reach clinical significance. Thus, the energy saving output of 2.5 volt could be programmed in almost every patient.

Administration, Topical↗

The environmental hazard caused by smelter slags from the Sta. Maria de la Paz mining district in Mexico.

The noxious potential of metallurgical tailings from the Ag/Pb/Zn/Cu mining district of Sta. María de la Paz (Mexico) is ascertained via the chemical characterization of slag material. Batch experiments using various extraction solutions (e.g. natural rainwater, water rich in humic substances, ammonium nitrate solution) revealed information on the dissolution behaviour of the elements Fe, Mn, Ni, Cu, Zn, As, Ba and Pb from slag with respect of grain size (slag material screened under 2 mm and analytically fine fraction) and elution time (2, 7.5, 24 and 240 h). An initial ecotoxicological assessment of the results is made and the environmental danger caused by large volumes of slag tailings is discussed.

Journal Article↗

Intracranial microembolic signals in 500 patients with potential cardiac or carotid embolic source and in normal controls.

BACKGROUND AND PURPOSE: We undertook this study to evaluate the prevalence and clinical correlations of Doppler microembolic signals (MES) in stroke-prone patients. METHODS: Patients with potential cardiac (n = 300) or carotid (n = 100) embolic source and control subjects (n = 100) were monitored with transcranial Doppler sonography for MES. Transthoracic (n = 192) and/or transesophageal (n = 134) echocardiography and carotid studies (continuous-wave Doppler, n = 181; color-coded duplex, n = 47) were performed in all patients with potential native cardioembolic source. Carotid disease was evaluated by means of continuous-wave Doppler (n = 87), color-coded duplex (n = 70), or intra-arterial angiography (n = 24) in patients with potential carotid embolic source. RESULTS: Overall MES prevalence was 23% in patients with potential native cardioembolic source (infective endocarditis [n = 7] 43%, left ventricular aneurysm [n = 38] 34%, intracardiac thrombus [n = 23] 26%, dilative cardiomyopathy [n = 39] 26%, nonvalvular atrial fibrillation [n = 24] 21%, valvular disease [n = 80] 15%), 55% in patients with prosthetic cardiac valves (mechanical [n = 77] 58%, porcine [n = 7] 43%, homografts [n = 5] 20%), 28% in patients with carotid disease (symptomatic [n = 46] 52%, asymptomatic [n = 54] 7%; P < .01), and 5% in control subjects. No relationship between MES counts and patients' age, sex, or actual medication was noted. The sensitivity and specificity of MES detection in identifying patients with potential embolic sources were 31% and 95%, respectively. CONCLUSIONS: Our study confirmed the reported clinical significance of MES in patients with carotid disease and the high specificity of this technique. The demonstrated low sensitivity of MES detection could be due to short monitoring duration or application of antihemostatic treatment. Prospective large-scale studies are needed to determine the definitive value of MES detection as a diagnostic method in patients with potential cardioembolic source.

Adult↗

Direct angiography of the coronary sinus: impact on left posteroseptal accessory pathway ablation.

The purpose of this study was to determine the incidence and types of venous branches and anomalies in posteroseptal accessory pathways (APs) and whether these findings are indicative for successful ablation sites. Some posteroseptal APs may be located epicardially, or may be associated with venous anomalies or related to the middle cardiac vein. These APs account for many of the failures encountered during endocardial ablation. Direct coronary sinus (CS) angiography was performed in 43 consecutive patients with left posteroseptal APs (n = 23) and in 20 patients with AV nodal reentrant tachycardia prior to catheter ablation. In 14 (61%) of 23 APs, a venous branch or an anomaly of the CS was found in the posteroseptal region (6 with middle cardiac vein, 2 with other ventricular venous branches, and 6 had a diverticulum). Eleven (48%) of 23 APs were successfully abolished from within that demonstrated venous system, with a median of four radiofrequency impulses. In the remaining 12 (52%) patients, ablation was attempted from the endocardial site of the mitral annulus. Repeat angiography after energy delivery revealed no major complications in any patient. One (5%) patient with AV nodal reentrant tachycardia had evidence of a CS anomaly (P < 0.01). Various types of venous branches and anomalies are associated with the majority of patients with left posteroseptal APs. The APs are directly related to these complex findings, and AP conduction can easily be eliminated from within the venous branches. CS angiography is suggested prior to catheter ablation of left posteroseptal APs to facilitate the ablation procedure.

Adult↗

Heart rate to work rate relation throughout peak exercise in normal subjects as a guideline for rate-adaptive pacemaker programming.

We investigated the physiologic heart rate (HR) to work rate (WR) relation throughout peak exercise in normal subjects as a guideline for rate-adaptive pacemaker slope programming. The study group consisted of 41 middle-aged subjects (22 men and 19 women) without evidence of cardiopulmonary disease. Peak-exercise stress tests were performed on a calibrated treadmill by using the symptom-limited "ramping incremental treadmill exercise" (RITE) protocol. The HR response, oxygen uptake, and treadmill workload increments were assessed simultaneously. The HR/WR slope, as determined using linear regression analysis, was 0.37 +/- 0.13 beats/min/W for the entire study group, which indicates an upper range increase of 5 beats/10 W increase of external treadmill work performed, using the mean value +/- 1 SD. Men generated an HR/WR slope of 0.32 +/- 0.09 beats/min/W, and women, 0.43 +/- 0.15 beats/min/W, indicating a significant sex-related difference in the HR/WR relation (p < 0.01). Thus, to achieve an appropriate matching of HR with patient effort, rate-adaptive pacemakers should generate an average increase of approximately 5 beats per increase in 10 W of external treadmill work. The HR/WR relation can easily be determined to provide the clinician with a minimal check system to avoid a hyper- or hypochronotropic paced response to exercise.

Adult↗

Randomized comparison of aspirin and phenprocoumon for prevention of right-sided thromboembolic complications associated with transvenous defibrillation leads.

Death due to pulmonary embolism caused by thrombosis formation along a pacing wire has been reported in patients with antibradycardia pacemakers. The purpose of this prospective and randomized study was to evaluate the effects of prophylactically assigned aspirin (100 mg per day) or phenprocoumon (a coumarin derivative) on the incidence of right-sided thromboembolic complications associated with transvenous defibrillation leads. Multiplane transoesophageal echocardiography and pulmonary scintigraphy were performed in 62 consecutive patients immediately and 6 +/- 2 months after transvenous defibrillator implantation. Aspirin or phenprocoumon was administered to the patients in a randomized and parallel manner. By means of multiplane transoesophageal echocardiography and pulmonary scintigraphy no thromboembolic events were observed immediately after transvenous defibrillator implantation. After 6 +/- 2 months, however, multiplane transoesophageal echocardiography disclosed thrombi on the transvenous leads in 13 of 62 patients (21%) despite antithrombotic therapy. At the same time, pulmonary scintigraphy did not reveal any defects compatible with pulmonary embolism. Although thrombi occurred in only four patients treated with phenprocoumon, but in nine patients receiving aspirin, this difference was statistically insignificant. Other variables associated with the occurrence of thrombosis formation were not identified. One fatal intracranial haemorrhage occurred in the phenprocoumon group.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The "low intensity treadmill exercise" protocol for appropriate rate adaptive programming of minute ventilation controlled pacemakers.

The objective of rate adaptive pacemakers that measure minute ventilation by transthoracic impedance is to simulate the physiological relationship of the sensed signal to the sinus node response during exercise, thus achieving an appropriate matching of heart rate with patient effort. The purpose of this study was to determine the physiological relationship between heart rate and minute ventilation (HR/VE) during peak exercise testing in order to develop a database for appropriate rate adaptive slope programming of minute ventilation controlled pacemakers. Due to several clinical limitations of peak exercise testing, it was additionally determined whether the 35-watt "low intensity treadmill exercise" (LITE) protocol can be used as a substitute for peak exercise test using the "ramping incremental treadmill exercise" (RITE) protocol in order to assess the correct HR/VE slope below the anaerobic threshold. The stress tests were performed on a treadmill with the collection of breath-by-breath gas exchange. Linear regression analysis was used to determine the HR/VE slope below and above the anaerobic threshold and during the early, dynamic phase of low intensity exercise with the RITE and LITE protocols, respectively. The results of this testing in 41 healthy subjects demonstrated that the HR/VE relationship throughout treadmill exercise using the RITE protocol was not linear but curvilinear in nature, with a steeper HR/VE slope of 1.54 +/- 0.51 below versus 1.15 +/- 0.37 above the anaerobic threshold (P < 0.005). The HR/VE slope determined during the early, dynamic phase of the LITE protocol (1.58 +/- 0.88) did not differ from the HR/VE slope from rest to anaerobic threshold obtained using the peak exercise RITE test (1.54 +/- 0.51; P = 0.79). Rate adaptive pacing should simulate the curvilinear relationship between heart rate and minute ventilation from rest to peak exercise. The HR/VE slope determined during the early, dynamic phase of low intensity exercise represents the HR/VE slope derived from the RITE protocol below the anaerobic threshold. According to the peak exercise database, the slope above anaerobic threshold can easily be calculated as a percentage of the slope below the anaerobic threshold. The LITE protocol can, therefore, be effectively performed as a substitute for peak exercise stress tests to determine the correct pacemaker rate response factor in order to obtain a physiological heart rate to minute ventilation relationship for the appropriate matching of paced heart rate with patient effort.

Anaerobic Threshold↗

Incidence of ICD lead related complications during long-term follow-up: comparison of epicardial and endocardial electrode systems.

UNLABELLED: The aim of this study was to evaluate the long-term stability of epicardial and endocardial lead systems for third-generation cardioverter defibrillators (ICDs) and to assess the usefulness of diagnostic tools. One hundred forty patients with 61 epicardial (43.6%) and 79 nonthoracotomy systems (56.4%) were followed for 25 +/- 19 months. A total of 18 (12.9%) lead related complications were documented. Complications of epicardial systems were detected in 10 patients (16.4%) during a follow-up time of 36 +/- 8 months: crinkling of patch electrodes in 6 patients (9.8%), insulation breakage of sensing electrodes in 2 patients (3.3%), and adapter defect in 2 patients (3.3%). Eight of the patients (10.1%) with transvenous-subcutaneous systems had lead related complications during a 13 +/- 6 months follow-up: fracture of the subcutaneous patch lead in 2 patients (2.5%), dislodgement of the right ventricular lead in 2 patients (2.5%), dislodgement of the superior vena cava lead in 2 patients (2.5%), insulation breakage of sensing electrodes in 1 patient (1.3%), and connector defect in 1 patient (1.3%). There was no significant difference in the incidence of lead related complications between epicardial and endocardial systems (P > 0.05). Fractures, dislodgements, and crinklings were documented within the first 8 +/- 5 months by regular chest X ray. Defects of insulation, adapter, or connector were detected 22 +/- 10 months after implantation and were associated with delivery of multiple inappropriate ICD therapies. An operative lead revision was indicated for 4 epicardial (6.6%) and 6 endocardial (7.6%) lead systems. CONCLUSIONS: Endocardial lead systems offer a similar long-term stability as compared to epicardial lead systems. Chest X ray is the most useful tool to detect lead fracture, dislodgment, and patch crinkling. Marker recordings or real-time electrograms have not been helpful in this series to identify patients with suspected lead defects prior to the experience of inappropriate ICD discharges.

Alloys↗

Changes in the amplitude of endocardial electrograms following defibrillator discharge: comparison of two lead systems.

Changes in the amplitude of endocardial electrograms after an unsuccessful shock attempt have been demonstrated to cause failure of redetection of ventricular fibrillation in patients using an integrated sense-pace defibrillating lead system. Thus, the objective of this study was to compare the effects of defibrillator shocks on the amplitude of endocardial electrograms in 26 patients using two different nonthoracotomy systems, a previous lead (model 0062) or a redesigned version (model 0072). At implant, bipolar endocardial electrograms were obtained before each shock application, during initial detection and redetection of ventricular fibrillation in case the applied shock was unsuccessful, and during intervals of 5, 10, 20, 30, 60, and 120 seconds after each shock delivery. No significant difference was noted in endocardial amplitudes between the lead models 0062 and 0072 during baseline sinus rhythm (12.2 +/- 4.6 mV vs 11.4 +/- 3.8 mV), and during initial ventricular fibrillation (7.0 +/- 2.4 mV vs 7.6 +/- 2.3 mV). During redetection of ventricular fibrillation, however, there was a significant difference (P = 0.0006) in endocardial amplitudes (3.4 +/- 1.9 mV vs 6.6 +/- 2.3 mV) between both leads tested. Comparing lead models 0062 and 0072, marked differences were found in endocardial amplitudes during sinus rhythm 5, 10, and 20 seconds after successful arrhythmia termination: 2.8 +/- 1.9 mV vs 8.6 +/- 2.9 mV (P < 0.0001), 4.6 +/- 2.9 mV vs 9.2 +/- 3.2 mV (P = 0.0007), and 6.4 +/- 4.0 mV vs 10.5 +/- 3.6 mV (P = 0.01). At predischarge testing, failure of redetection of ventricular fibrillation was documented in two patients with the lead model 0062 requiring external defibrillation to restore sinus rhythm. These findings demonstrate a significant less postshock attenuation of the endocardial electrogram amplitudes during persistent ventricular fibrillation after an unsuccessful shock attempt as well as during sinus rhythm immediately following an effective shock delivery using the redesigned lead system model 0072 compared to the electrogram amplitudes obtained in patients using the previous lead model 0062.

Adult↗

Intravenous adenosine during atrioventricular reentrant tachycardia: induction of atrial fibrillation with rapid conduction over an accessory pathway.

Adenosine is considered to be a safe agent for termination of orthodromic atrioventricular reentrant tachycardia in patients with accessory pathways. A case with initially successful accessory pathway ablation and without preexcitation during sinus rhythm is presented, in which intravenous adenosine (6 mg) during orthodromic tachycardia was followed by atrial fibrillation and sudden onset of preexcitation with subsequent rapid ventricular response with moderate hemodynamic compromise.

Adenosine↗

Effects of nuclear magnetic resonance imaging on cardiac pacemakers.

Patients with cardiac pacemakers are currently restricted from nuclear magnetic resonance imaging (MRI). The aim of the study was to analyze the influence of MRI on new generation pacemakers. Tests were performed using a phantom model with seven dual chamber and two single chamber systems in a 0.5 Tesla MRI scanner. Monitoring by telemetry and oscillography were used during the standard clinical scan sequences as well as a pacemaker inquiry after each sequence. Spin echo, gradient echo, and fast field echo sequences were performed with the following stimulation modes: VVI, VVIR, VOO, DDD, DDDR, and DOO. On entering the static magnetic field, the reed switch was activated followed by asynchronous stimulation. The subsequent scan showed no influence on the stimulation function nor on the pacemaker program. Event counter function remained intact. Pacemakers with automatic mode switching to demand pacing or programmed inactivation of the reed switch were triggered in the dual chamber mode and were inhibited in the one chamber mode during the scan. Alterations of pacemaker program or rapid pacing were not observed. MRI scan could induce voltage as high as intracardiac signals, but the stimulation threshold of the heart was not reached. Thus, pacemakers should be programmed in the asynchronous mode during scan to avoid inhibition and trigger mechanism.

Acrylic Resins↗

Echocardiographic imaging of coronary sinus diverticula and middle cardiac veins in patients with preexcitation syndrome: impact on radiofrequency catheter ablation of posteroseptal accessory pathways.

To determine the value of echocardiography for identifying coronary sinus (CS) diverticula and middle cardiac veins (MCVs) in patients with posteroseptal accessory pathways (PAPs), transthoracic (TTE) and transesophageal echocardiography (TEE) were performed in 18 consecutive patients with PAP and in 15 control subjects with left lateral accessory pathway before CS angiography. The size, shape, and location of CS diverticula and MCV were described and compared to angiography. TEE and angiography were concordant for the identification of diverticula (n = 5) and agreed for depicting MCV in 22 of the 27 cases. TTE revealed 4 of 5 diverticula and identified 4 of 27 MCV (P < 0.001). Fourteen MCV but no diverticula were found in the control subject. There was no significant difference between transesophageal and angiographic measurements for the width (23.5 +/- 4.9 vs 26.8 +/- 6.6 mm) and height (13.5 +/- 3.8 vs 15.7 +/- 3.4 mm) of the diverticula, and the width (3.5 +/- 0.7 vs 3.7 +/- 0.6 mm) of MCV. TEE underestimated the length of the MCV (12.0 +/- 1.8 vs 27.2 +/- 6.0, P < 0.001). Delivery of radiofrequency energy within the neck of a diverticulum or within an MCV was successful in 5 of 5, and 6 of 13 cases in patients with PAPs, respectively. In conclusion, echocardiography was as reliable as angiography for detecting and describing CS diverticula and MCV in patients with preexcitation syndrome. Echocardiography is recommended prior to electrophysiological study because it may simplify radiofrequency catheter ablation.

Adult↗

Impact of the local atrial electrogram in AV nodal reentrant tachycardia: ablation versus modification of the slow pathway.

INTRODUCTION: The purpose of this study was to determine the predictors of successful ablation versus modification sites of the slow pathway in patients with AV nodal reentrant tachycardia. Complete elimination of slow pathway conduction ("ablation") is considered to be an appropriate endpoint during radiofrequency (RF) current delivery, whereas the persistence of residual slow pathway conduction with or without single echo beats ("modification") may be indicative of tachycardia recurrence. METHODS AND RESULTS: Of 131 patients, 71 consecutive patients were followed for 15.1 +/- 7.6 months. After elimination of inducible AV nodal reentrant tachycardia in all patients, residual slow pathway conduction (modification) persisted in 38 patients, whereas complete elimination of slow pathway conduction (ablation) was documented in 33 patients. Including electrophysiologic study after 5 to 7 days and after 3 to 6 months, 6 (8.4%) patients had recurrences: 5 with residual slow pathway conduction after the procedure and 1 with complete elimination of slow pathway conduction (P < 0.05). As compared with modulated sites, ablation sites of the slow pathway were characterized as follows: (1) duration of the local atrial electrogram (AEGM) (66.7 +/- 10.2 vs 54.1 +/- 12.6 msec, P < 0.01); (2) interval from the end of the AEGM to onset of His-bundle deflection (4.4 +/- 8.2 vs 16.1 +/- 9.3 msec, P < 0.01); and (3) number of peaks of the AEGM as an indicator of fractionation (4.1 +/- 0.7 vs 3.0 +/- 0.8, P < 0.01). The rate of junctional tachycardias (103.4 +/- 12.1 vs 102.1 +/- 16.9 per min), the AV ratio (0.4 +/- 0.5 vs 0.5 +/- 0.5), the number of RF current deliveries (4.1 +/- 4.4 vs 4.5 +/- 4.4), the duration of the procedure (124.1 +/- 45.3 vs 125.6 +/- 42.3 min), and the fluoroscopy time (15.5 +/- 10.8 vs 16.6 +/- 9.6 min) as well as power and total energy of RF current deliveries and the anatomically calculated catheter position at the successful site were not statistically different. A subset analysis in patients who received only a single RF application showed the same results for both groups. Patients without recurrence (n = 65) were found to have longer duration of the AEGM (61.9 +/- 14.6 msec) and a shorter interval from the end of AEGM to the onset of His-bundle deflection (10.1 +/- 12.2 msec) than patients with recurrence (n = 6) (47.5 +/- 7.5 msec and 20.8 +/- 12.8 msec, respectively). CONCLUSION: Complete ablation of the slow pathway resulted in a lower recurrence rate. The complete ablation approach is feasible using precisely analyzed local AEGMs to guide RF current in AV nodal reentrant tachycardia in a short procedure time.

Adult↗

Slowing of the ventricular rate during atrial fibrillation by ablation of the slow pathway of AV nodal reentrant tachycardia.

INTRODUCTION: The mechanisms whereby radiofrequency catheter modification of AV nodal conduction slows the ventricular response are not well defined. Whether a successful modification procedure can be achieved by ablating posterior inputs to the AV node or by partial ablation of the compact AV node is unclear. We hypothesized that ablation of the well-defined slow pathway in patients with AV nodal reentrant tachycardia would slow the ventricular response during atrial fibrillation. METHODS AND RESULTS: In 34 patients with dual AV physiology and inducible AV nodal reentrant tachycardia, atrial fibrillation was induced at baseline and immediately after successful slow pathway ablation and at 1-week follow-up. The minimal, maximal, and mean RR intervals during atrial fibrillation increased from 353 +/- 76, 500 +/- 121, and 405 +/- 91 msec to 429 +/- 84 (P < 0.01), 673 +/- 161 (P < 0.01), and 535 +/- 98 msec (P < 0.01), respectively. These effects remained stable during follow-up at 1 week. The AV block cycle length increased from 343 +/- 68 msec to 375 +/- 60 msec (P < 0.05) immediately and to 400 +/- 56 msec (P < 0.01) at 1-week follow-up. The effective refractory period of the AV node prolonged from 282 +/- 83 msec to 312 +/- 89 msec and to 318 +/- 81 msec after 1 week (P < 0.05), respectively. CONCLUSION: This study shows a decrease in ventricular response to pacing-induced atrial fibrillation after ablation of the slow pathway in patients with AV nodal reentrant tachycardia. Since the AV nodal conduction properties could be defined, this study supports the hypothesis that the main mechanism of AV nodal modification in chronic atrial fibrillation is caused by ablation of posterior inputs to the AV node.

Atrial Fibrillation↗

[Prognostic value of signal averaged ECG in dilated cardiomyopathy with spontaneous and induced ventricular tachyarrhythmias].

UNLABELLED: Ventricular late potentials in signal-averaged ECG are a predictor of ventricular tachyarrhythmias in patients with coronary artery disease. The role of signal-average ECG in non-ischemic dilated cardiomyopathy has not been defined yet. We studied the prognostic impact of an abnormal signal-averaged ECG in 31 patients with non-ischemic dilated cardiomyopathy. All signal-averaged ECG recordings were analyzed by time-domain analysis as well as by frequency analysis with spectrotemporal mapping. RESULTS: In 13 (42%) patients time domain analysis and in 9 (29%) patients frequency analysis was found to be abnormal. During follow-up (13 +/- 7 months) seven (23%) patients developed spontaneous ventricular tachyarrhythmias. The mean ejection fraction and the results of programmed ventricular stimulation did not differ significantly between patients with and without clinical episodes. Abnormal time domain analysis was found in five (71%) patients with and in eight (33%) patients without spontaneous tachyarrhythmias (p = 0.07), and abnormal frequency analysis in 3 (43%) patients versus 6 (25%) patients (p = 0.36). The low-amplitude-signal duration was significantly increased in patients with tachyarrhythmias (p = 0.008). Ventricular tachyarrhythmias occurred in 38% of patients with abnormal time domain analysis and in 33% of patients with abnormal frequency analysis. In patients with normal signal-averaged ECG the incidence reached 11% and 18%. For time-domain analysis the sensitivity was 71%, specificity 67%, positive predictive value 38%, and negative predictive value 89%, for spectrotemporal mapping 43%, 75%, 33%, and 82%, respectively. The incidence of electrophysiologically inducible ventricular tachyarrhythmias in patients with abnormal signal-averaged ECG exceeded that in patients with normal findings. CONCLUSION: In patients with non-ischemic dilated cardiomyopathy a normal signal-averaged ECG is associated with a reduced occurrence of ventricular tachyarrhythmic events. Thus, signal-averaged ECG contributes to the evaluation of these patients. The negative predictive value exceeded the positive predictive value.

Adult↗

Color-coded Doppler imaging of the vena contracta as a basis for quantification of pure mitral regurgitation.

The narrowest central flow region of a jet is defined as the vena contracta. This term is applied also to the contracted zone of the Doppler color flow image of a jet at its passage through an incompetent mitral valve. The clinical applicability of measuring the size of the vena contracta by transthoracic color-coded Doppler echocardiography for estimating the severity of mitral regurgitation (MR) was evaluated. In 78 of 82 patients with angiographically proved MR, a coherent flow image across the valve was visualized. The maximal diameter in the apical long-axis view was considered as a representative value for the size of the vena contracta. In comparison with the maximal left atrial velocity pixel area, this parameter revealed higher correlations to the angiographic degree of MR and to the regurgitant volume (r = 0.94 vs 0.72, and 0.83 vs 0.71, respectively). The highest positive and negative predictive accuracies for differentiating mild-to-moderate from severe MR were determined for a diameter of 6.5 mm (88 and 96%, respectively). Because the vena contracta is directly related to the severity of MR, it is concluded that it is helpful to use this parameter instead of the maximal velocity pixel area for semiquantitative grading.

Adult↗

Interactions between drugs and devices: experimental and clinical studies.

It is important to understand the potential interactions between the implantable cardioverter defibrillator (ICD) and antiarrhythmic therapy in patients who receive pharmacologic therapy as an adjunct to ICD therapy. In our cohort of 101 patients, antiarrhythmic agents were prescribed in 67% of the patients during long-term therapy for the following reasons: to suppress ventricular tachycardia/ventricular fibrillation episodes (50%), to lower the rate of ventricular tachycardia (19%), to prevent supraventricular tachyarrhythmia (21%), and for other reasons (10%). The potential influence of antiarrhythmic drugs on the defibrillation threshold (DFT) is the most important issue. In animal studies lidocaine increased the DFT in a dose-dependent manner. Quinidine, procainamide, propafenone, and flecainide did not affect the DFT or, in some cases, led to a small increase. Sotalol even decreased the energy requirements for internal defibrillation. In a prospective investigation we were able to document a significant increase of DFT (from 14.1 + 3.0 to 20.9 + 5.4 J, p < 0.001) by the use of amiodarone (400 mg/day), whereas this effect was not found in patients who received mexiletine (720 mg/day). In conclusion, the DFT or the safety margin for defibrillation should be known before antiarrhythmic agents are administered to patients with an ICD. In case of a small safety margin, the DFT should be reassessed after antiarrhythmic drug therapy is begun.

Animals↗

Clinical efficacy of shock waveforms and lead configurations for defibrillation.

A randomized, prospective comparison of the defibrillation efficacy of various shock waveforms and nonthoracotomy lead configurations was performed in five distinct patient groups undergoing implantation of a cardioverter defibrillator. In the first group using a bidirectional lead configuration, there was no significant difference in the mean defibrillation threshold (DFT) between simultaneous and sequential monophasic shocks (17.8 +/- 5.8 joules versus 17.3 +/- 2.7 joules). In the second group using a bidirectional lead configuration, the mean DFT was 21.9 +/- 7.3 joules with monophasic shocks and 14.9 +/- 5.0 joules with biphasic shocks (p < 0.001). In the third group using a unidirectional lead configuration, the mean DFT was significantly higher (p < 0.001) with monophasic shocks (22.1 +/- 4.2 joules) compared with biphasic shocks (15.0 +/- 5.4 joules). In the fourth group, an intraindividual comparison with monophasic shock waveforms showed no significant differences in DFT using either a bidirectional (21.3 +/- 5.8 joules) or a unidirectional (21.7 +/- 2.6 joules) lead configuration. In the fifth group, a simplified unipolar transvenous defibrillation lead system ("active can") demonstrated significant lower DFTs (9.7 +/- 3.8 joules) compared with a standardized unidirectional lead configuration (18.0 +/- 6.8 joules). It is concluded that: (1) there seems to be no significant difference in the DFT between simultaneous and sequential monophasic shocks; (2) biphasic waveforms require significantly less energy for defibrillation than their corresponding monophasic waveforms; and (3) the unipolar single-electrode defibrillation system is easy to implant and provides DFTs at energies comparable with epicardial lead systems.

Adolescent↗