Integrated head-thoracic vascular MRI at 3 T: assessment of cranial, cervical and thoracic involvement of giant cell arteritis.

Recently, high-resolution contrast-enhanced MRI has proven to be feasible for noninvasive diagnosis of giant cell arteritis in the cranium. In such examinations, thickening of the vessel wall and/or increased contrast enhancement demonstrate mural inflammation. Typically, the superficial cranial arteries with predominance of the superficial temporal artery are affected by the disease. However, giant cell arteritis can also involve other parts of the vascular system and an examination with extended coverage, including head, neck, and thorax would be advantageous. In this study, a novel approach for integrated head-thoracic vascular MRI at 3 T is presented. Combining first-pass imaging of a single-dose contrast agent with post-contrast imaging permits the assessment of both thoracic aortic geometry and wall, in addition to high-resolution head imaging needed for the analysis of the small superficial cranial arteries. Results from a patient feasibility study are presented and confirm that the protocol can successfully be completed in less than 40 min.

Aged↗

Analysis and compensation of eddy currents in balanced SSFP.

Balanced steady-state free precession (SSFP) completely compensates for all gradients within each repetition time (TR), and is thus very sensitive to any magnetic field imperfection that disturbs the perfectly balanced acquisition scheme. It is demonstrated that balanced SSFP is especially sensitive to changing eddy currents that are induced by stepwise changing phase-encoding (PE) gradients. In contrast to the linear k-space trajectory, which has small variations between consecutive encoding steps, other encoding schemes (e.g., centric, random, or segmented orderings) exhibit significant jumps in k-space between adjacent PE steps, and consequently induce rapidly changing eddy currents. The resulting disturbances induce significant image artifacts, such that compensation strategies are essential when nonlinear PE schemes are applied. Although direct annihilation of the induced eddy currents by additional, opposing magnetic fields has been investigated, it is limited by uncertainty regarding the time evolution of induced eddy currents. A generic (and thus system-unrelated) compensation strategy is proposed that consists of "pairing" of consecutive PE steps. Another approach is based on partial dephasing along the slice direction that annihilates eddy-current-induced signal oscillations. Both pairing of the PE steps and "through-slice equilibration" are easy to implement and allow the use of arbitrary k-space trajectories for balanced SSFP.

Algorithms↗

Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need to be acquired at specific delays following magnetization preparation or for transient artifact reduction in cardiac-gated k-space segmented CINE imaging. Such trajectories are problematic for balanced SSFP imaging due to nonconstant eddy current effects and resulting disruption of the steady state. In this work, a novel acquisition strategy for balanced SSFP imaging is presented that utilizes scan time reduction by parallel imaging for optimized "double average" eddy current compensation and artifact reduction during the transient phase following steady-state storage and magnetization preparation. Double average parallel SSFP imaging was applied to k-space segmented CINE SSFP tagging as well as nongated centrically encoded SSFP imaging. Phantom and human studies exhibit substantial reduction in steady-state storage and eddy current artifacts while maintaining spatial resolution, signal-to-noise ratio, and similar total scan time of a standard SSFP acquisition. The proposed technique can easily be extended to other acquisition schemes that would benefit from nonlinear reordering schemes and/or rely on interruption of the balanced SSFP steady state.

Algorithms↗

Balanced phase-contrast steady-state free precession (PC-SSFP): a novel technique for velocity encoding by gradient inversion.

A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady-state free precession (SSFP) imaging, and is thus termed PC-SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to keep the repetition time (TR) as short as in typical SSFP imaging sequences. Sensitivity to through-plane velocities was instead established by inverting (i.e., negating) all gradients along the slice-select direction. Velocity sensitivity (VENC) could be adjusted by altering the first moments of the slice-select gradients. Disturbances of the SSFP steady state were avoided by acquiring different flow echoes in consecutively (i.e., sequentially) executed scans, each over several cardiac cycles, using separate steady-state preparation periods. A comparison of phantom measurements with those from established 2D-cine-PC MRI demonstrated excellent correlation between both modalities. In examinations of volunteers, PC-SSFP exhibited a higher intrinsic signal-to-noise ratio (SNR) and consequently low phase noise in measured velocities compared to conventional PC scans. An additional benefit of PC-SSFP is that it relies less on in-flow-dependent signal enhancement, and thus yields more uniform SNRs and better depictions of vessel geometry throughout the whole cardiac cycle in structures with slow and/or pulsatile flow.

Blood Flow Velocity↗

Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging.

Nonuniformities of magnetic field gradients can cause serious artifacts in diffusion imaging. While it is well known that nonlinearities of the imaging gradients lead to image warping, those imperfections can also cause spatially dependent errors in the direction and magnitude of the diffusion encoding. This study shows that the potential errors in diffusion imaging are considerable. Further, we show that retrospective corrections can be applied to reduce these errors. A general mathematical framework was formulated to characterize the contribution of gradient nonuniformities to diffusion experiments. The gradient field was approximated using spherical harmonic expansion, and this approximation was employed (after geometric distortions were eliminated) to predict and correct the errors in diffusion encoding. Before the corrections were made, the experiments clearly revealed marked deviations of the calculated diffusivity for fields of view (FOVs) generally used in diffusion experiments. These deviations were most significant farther away from the magnet's isocenter. For an FOV of 25 cm, the resultant errors in absolute diffusivity ranged from approximately -10% to +20%. Within the same FOV, the diffusion-encoding direction and the orientation of the calculated eigenvectors can be significantly altered if the perturbations by the gradient nonuniformities are not considered. With the proposed correction scheme, most of the errors introduced by gradient nonuniformities can be removed.

Anisotropy↗

Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions.

To characterize gradient field nonuniformity and its effect on velocity encoding in phase contrast (PC) MRI, a generalized model that describes this phenomenon and enables the accurate reconstruction of velocities is presented. In addition to considerable geometric distortions, inhomogeneous gradient fields can introduce deviations from the nominal gradient strength and orientation, and therefore spatially-dependent first gradient moments. Resulting errors in the measured phase shifts used for velocity encoding can therefore cause significant deviations in velocity quantification. The true magnitude and direction of the underlying velocities can be recovered from the phase difference images by a generalized PC velocity reconstruction, which requires the acquisition of full three-directional velocity information. The generalized reconstruction of velocities is applied using a matrix formalism that includes relative gradient field deviations derived from a theoretical model of local gradient field nonuniformity. In addition, an approximate solution for the correction of one-directional velocity encoding is given. Depending on the spatial location of the velocity measurements, errors in velocity magnitude can be as high as 60%, while errors in the velocity encoding direction can be up to 45 degrees. Results of phantom measurements demonstrate that effects of gradient field nonuniformity on PC-MRI can be corrected with the proposed method.

Blood Flow Velocity↗

Flow effects in balanced steady state free precession imaging.

An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady-state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various through-plane flow waveforms and rates were modeled numerically considering factors such as the excitation slice profile and both in- and out-flow effects. Phantom measurements in an experimental setup that allowed the assessment of SSFP signal properties as a function of frequency offset and flow rate demonstrated that the computer simulations provided a suitable description of the effects of flow in SSFP imaging. A volunteer scan was performed to provide in vivo validations. For accurate modeling of SSFP signal intensities it is crucial to include effects such as imperfect slice profiles and, more importantly, "out-of-slice" contributions to the signal. Both simulations and experiments show that there can be considerably large-frequency offset dependent-signal contributions from flowing spins that have already left the imaging slice but still add to the SSFP signal. Although spins leaving the slice do not experience additional RF-excitation, gradient activity is not confined to the region of excitations and the balanced nature of the SSFP imaging gradients allows "out-of-slice" transverse magnetization to contribute to the total SSFP signal, effectively by broadening the slice thickness for flowing spins. This results in a frequency dependence of in-flow related signal enhancement and flow artifacts.

Artifacts↗

Phase contrast MRI with improved temporal resolution by view sharing: k-space related velocity mapping properties.

Phase contrast techniques in combination with k-space segmented CINE imaging are widely used for the quantitative assessment of blood flow or tissue motion. The temporal resolution of the corresponding pulse sequences plays an important role concerning the potential of the method to fully detect time resolved flow or motion patterns. A further improvement of temporal or spatial resolution in phase contrast CINE MRI can be achieved by the application of view sharing. Based on simulations with point-spread-functions resulting from different cyclic flow or motion patterns an analysis of view sharing techniques in combination with phase contrast MRI is presented. Velocity mapping properties and the role of different k-space regions concerning the resulting values in the phase images and thus encoded velocities were investigated. It could be shown that the velocity induced phase shifts in phase contrast techniques are mainly encoded in the central sections of k-space which makes view sharing also suitable for velocity mapping. As a result the use of appropriate sampling and data acquisition schemes permits the assessment of flow or motion patterns with significantly improved temporal resolution without loss of functional information. In addition phantom measurements with an oscillation phantom were performed in order to validate the simulation results and to demonstrate the potential of view sharing techniques to accelerate phase contrast imaging and improve the detection of the underlying flow or motion dynamics.

Blood Flow Velocity↗

Spiral reconstruction by regridding to a large rectilinear matrix: a practical solution for routine systems.

Spiral trajectories offer a number of attractive features for fast imaging. A practical problem for the implementation on routine magnetic resonance scanners is the lack of appropriate and efficient reconstruction algorithms in the available scanner software. In this paper, a simple way to implement a spiral reconstruction algorithm is described that avoids the data interpolation required by gridding approaches commonly used. Using the optimized fast Fourier transform built into each scanner, it offers image reconstruction times of less than 1 second and thus allows the introduction of spiral imaging to routine scanners.

Algorithms↗

Cardiac phase contrast gradient echo MRI: measurement of myocardial wall motion in healthy volunteers and patients.

A number of methods have been proposed for the noninvasive measurement of myocardial wall motion. The paper describes a strategy for assessing myocardial motion based on the sensitivity of the phase of the MR-signal to motion using a breath-hold phase contrast technique. A motion-sensitized and a motion-compensated MR-signal are measured during successive scans. The difference between the two MR-signals is used to calculate myocardial velocity in all three spatial dimensions. Postprocessing includes the transformation of the measured velocities into an internal coordinate system of the left ventricle. Also various presentation modes and further processing of the received velocity information are provided including calculation of global motion parameters. We examined 20 patients suffering from myocardial infarction. The overall left ventricular motion can be characterized by appropriate parameters describing the rotation and contraction or expansion, respectively. Regional motional disturbances are visualized using parametric images. Contrary to the highly consistent interindividual data in normal volunteers, patients showed significant localized motion deficits.

Adult↗

Analysis of myocardial motion based on velocity measurements with a black blood prepared segmented gradient-echo sequence: methodology and applications to normal volunteers and patients.

The paper describes a strategy for measuring and characterizing myocardial motion in terms of velocity parameters derived from measurements with a segmented black blood prepared phase contrast gradient echo sequence. The characteristic parameters are calculated by transforming the velocities measured on a pixel-by-pixel basis across the left ventricle from the laboratory frame of reference into a cylindrical coordinate system, in which the motion velocities within the short axis plane are represented in polar coordinates and which is located at the center of the myocardium and moving with it over the ECG cycle. First results in a study with 12 healthy volunteers gave highly consistent values for the radial (expansion/compression) as well as the rotational velocities. Except for one volunteer, motion at the R wave of the ECG starts with clockwise rotation, followed by contraction and expansion accompanied by counterclockwise rotation. First examinations of patients with global and focal disease demonstrate the potential to detect disturbances in the local as well as the overall motion patterns.

Adult↗

Cardiac phase contrast gradient echo MRI: characterization of abnormal left ventricular wall motion in patients with ischemic heart disease.

PURPOSE: In our patient study, we examined the clinical usefulness of phase contrast velocity mapping for the detection and characterization of localized abnormalities of left ventricular motion. MATERIALS AND METHODS: Velocity encoding is based on the fact that motion in the presence of a magnetic field gradient causes a change of the phase of the MRI signal that is proportional to the velocity of tissue motion. Left ventricular motion was characterized by parameters describing rotation and contraction/dilatation, respectively. We examined 34 patients with localized abnormalities of left ventricular motion due to ischemic heart disease. RESULTS: Three patients could not be sufficiently evaluated due to technical problems including varying positions of the heart during successive breathhold periods. In 27 of the remaining 31 patients, MRI could demonstrate abnormal radial velocities that corresponded fully or partly with perfusion deficits in single photon emission computed tomography or positron emission tomography. The abnormalities were most pronounced in early diastole. Rotational velocities did not show any regional changes. CONCLUSION: Our study showed that our technique is suitable for the detection and characterization of localized abnormalities of left ventricular motion in patients with ischemic heart disease.

Adult↗