PubMed Health⌕ Search

Biomedical subjects

M Meine

Publications and source records attributed to M Meine.

12 recordsLinked to original sources

[Current aspects of defibrillator therapy in congestive heart failure].

The beneficial effects of implantable cardioverter defibrillator (ICD) therapy in patients (pts) with life-threatening ventricular tachyarrhythmias and impaired left ventricular (LV) function is still unclear. We studied the follow-up of 410 pts (368 males, 42 females, mean age 57 +/- 11 years) after ICD implant. The LV function was assessed by the New York Heart Association functional class of heart failure (NYHA). Fifty pts (12%) were in NYHA I-II, 151 pts (37%) in NYHA II, 117 pts (29%) in NYHA II-III and 92 pts (22%) in NYHA III. Epicardial ICD implantation was performed in 209 pts (51%) and 201 pts (49%) received nonthoracotomy ICDs. Perioperatively (within 30 days after implant), 12 pts (3%) died, significantly more frequent after epicardial (11 of 209 pts, 5%) than after transvenous ICD implant (1 of 201 pts, < 1%) (p < 0.05). During a mean follow-up of 28 +/- 24 months (range < 1 to 114 months), 90 pts (23%) died: 9 pts (2%) died from sudden arrhythmic death and 5 pts (1%) suddenly, but probably not from arrhythmic causes; 55 pts (14%) died from cardiac causes (congestive heart failure, myocardial reinfarction) and 21 pts (5%) from noncardiac causes. The 3-year, 5-year and 7-year survival was 92% to 96% for arrhythmic mortality in NYHA class I, II and III compared to the 3-year survival of 94%, and a 5-year and 7-year survival of 84% in patients with NYHA class II-III. 338 pts (82%) received ICD shocks (mean incidence 21 +/- 43 shocks per pt); pts in NYHA class II (83%), class II-III (84%), class III (90%) received ICD discharges significantly more frequently than in class I-II (64%) (p < 0.05). Our data show that pts with LV dysfunction benefit from ICD therapy and that these pts survive for a considerable time after the first shock. However, survival is clearly influenced by the degree of left ventricular dysfunction and, in addition to ICD therapy, aggressive treatment of heart failure is necessary.

Aged↗

Assessment of the chronotropic response at the anaerobic threshold: an objective measure of chronotropic function.

The evaluation of the heart rate response to exercise is important for the diagnosis of chronotropic incompetence and the assessment of a rate responsive algorithm of sensor-controlled pacemakers. The aim of the present study was to examine a classification of the chronotropic response at an individually moderate exercise level. Sixteen pacemaker patients (patient group, age 62.9 +/- 7.6 years) with sick sinus syndrome and 15 age-matched healthy subjects (control group, age 57.6 +/- 9.4 years) underwent a maximum cardiopulmonary exercise test on a treadmill after a protocol with individually selected incremental steps. To analyze the patients' intrinsic heart rate response, the rate responsive mode of the pacemaker was switched off. Chronotropic incompetence was diagnosed in eight patients whose maximal heart rate was < 80% of the age-predicted heart rate. The heart rate at the anaerobic threshold was significantly lower in the chronotropically incompetent subgroup than in the chronotropically competent patients and the healthy subjects (85.9 +/- 6.6 beats/min vs 100.3 +/- 9.9 beats/min and 112.9 +/- 11.7 beats/min, respectively). The chronotropic slope of the heart rate reserve as a function of the metabolic reserve was significantly higher in the control group than in the patient groups with either mild or severe chronotropic incompetence (0.94 +/- 0.17 vs 0.64 +/- 0.08 and 0.43 +/- 0.14, respectively). Furthermore, the chronotropically incompetent response could be divided into a linear type with and without a threshold, an exponential, and a logarithmic type. The anaerobic threshold was an objectively detectable breakpoint at an individually moderate exercise level that could be used for characterization of chronotropic function. At the anaerobic threshold, a physiological heart rate response was about 220--age--50 beats/min. A deviation of more than 10 beats/min below this physiological value characterized chronotropic incompetence.

Algorithms↗

Restoration of cardio-circulatory regulation by rate-adaptive pacemaker systems: the bioengineering view of a clinical problem.

In the past, the development of rate-adaptive (sensor-controlled) pacemaker systems seems to have been determined primarily by the availability, compatibility and other properties of the technical sensor. This paper, however, focuses on the system-physiological aspect in an attempt to answer the question to what extent physiological cardiovascular control is restored by the pacemaker system. This is a question which should be asked before attempting to design a sensor-controlled system and especially before designing multisensor systems with infinite combinations. Four categories are defined: direct bridging ("shunting"), open loop systems, closed systems using cardiorespiratory or metabolic coupling and those using cardiac signals. Further subdivisions are shown. From the bioengineering as well as from the physiological viewpoint a system should preferably not combine sensors from one and the same of these categories. At present direct bridging is available only for the atrioventricular (AV)-block, so that for sick-sinus-syndrome (SSS) patients feedback control via cardiac signals ("inotropic" pacemaker) comes nearest the goal without, however, ideally bridging the gap. Open-loop systems should no longer be developed as single-sensor systems. A well developed activity sensor, however, which quickly pinpoints the most prominent stressor of cardiovascular control is best suited to complement another sensory system achieving closed-loop control. New and promising concepts orientated toward direct bridging are the analysis of monophasic action potentials and the "dromotropic" concept, both of which seek direct correlation with the "chronotropic" information not available in SSS patients.

Adaptation, Physiological↗

Influence of the pacing rate on the atrioventricular conduction time during aerobic and anaerobic exercise: basic concepts for a dromotropically controlled rate responsive pacemaker.

The dromotropic pacemaker concept needs a rate responsive algorithm in which the pacing rate is controlled by the atrioventricular conduction time (AVCT). To develop basic concepts for such a rate responsive algorithm, the influence of the pacing rate on the AVCT was investigated. Seven patients (62 +/- 7.8 years) with sick sinus syndrome and intact atrioventricular conduction underwent two cardiopulmonary exercise tests (CPX) on a treadmill. According to the determination of the anaerobic threshold (AT) and the patients maximum capacity in the first incremental CPX the work rate for two exercise levels below and above the AT were chosen for the second constant workload CPX. The calculation of the optimal pacing rate (HRopt) was based on the oxygen uptake (VO2) during exercise after reaching steady-state conditions. According to the increase of the VO2 from 14.8 +/- 2.3 mL/min per kilogram during aerobic work (38.3 +/- 16.0 W) to 19.4 +/- 4.7 mL/min per kilogram during anaerobic work (80.6 +/- 32.3 W), the HRopt was calculated to be 98.6 +/- 6.9 beats/min and 116.4 +/- 4.7 beats/min. Starting from HRopt, the pacing rate was increased (overpacing) and decreased (underpacing) by about 5 beats/min every minute. At optimal pacing rate the AVCT decreased significantly from 233.0 +/- 30.5 ms during aerobic work and to 226.4 +/- 27.3 ms during anaerobic work (P < 0.05). Whereas overpacing induced a significant prolongation of the AVCT during aerobic work (4.17 +/- 1.78 ms per 10 beats/min) and anaerobic work (3.84 +/- 1.60 ms per 10 beats/min), underpacing yielded a significant shortening of the AVCT by about 4.49 +/- 2.64 ms per 10 beats/min during aerobic work and 4.75 +/- 1.87 ms per 10 beats/min during anaerobic work (P < 0.01). The slopes of the regression lines of the relationship between AVCT and pacing rate were not significantly. different. Based on the reciprocal relationship of heart rate (HR) and AVCT, basic concepts may be established for a dromotropic rate responsive algorithm.

Aged↗

Relationship between atrioventricular delay and oxygen consumption in patients with sick sinus syndrome: relevance to rate responsive pacing.

To develop a dromotropic-controlled rate adaptive algorithm for patients with sick sinus syndrome (SSS) and intact AV conduction, 14 pace-maker patients with SSS underwent cardiopulmonary exercise testing (CPX). During exercise, the pace-maker was programmed in an AAT mode without rate adaptation, whereby 3 patients developed supraventricular arrhythmia and 11 patients kept sinus rhythm. Chronotropic incompetence (CI) at heart rate (HR) < 95 beats/min at the anaerobic threshold (AT) was found in five patients. In patients with chronotropic competence (CC), the HR increase was significantly greater than in CI patients (rest: 73.2 +/- 12.6 vs. 64.2 +/- 4.0 beats/min;AT:101.2 +/- 6.2 vs. 82.0 +/- 5.1 beats/min;peak: 135.2 +/- 10.7 vs. 103.2 +/- 10.9 beats/min). There was no significant difference in the AVD between CC and CI patients (rest: 167.7 +/- 38.6 vs. 170.8 +/- 22.5 ms, AT: 156.2 +/- 30.7 vs. 163.6 +/- 21.6 ms, peak: 144.7 +/- 29.0 vs. 152.4 +/- 15.0 ms). The correlation coefficient between HR increase and VO2 was +1.0 and between AVD decrease and VO2 - 1.0 in both groups. An increase in pacing rate from 75 beats/min to 120 beats/min without exercise (overpacing) led to a prolongation of the AV interval of about 30.6 +/- 14.2 ms. Based on this closed loop control with negative feedback, a dromotropic rate adaptive algorithm for patients with SSS and intact AV conduction could be developed.

Aged↗

[Intravascular ultrasound findings in calcifying arteriosclerosis: in vitro validation using "soft" roentgen images].

AIM: The aim of this study was to validate the detection of calcified arteriosclerotic plaques with intravascular ultrasound (IVUS). METHOD: 181 arteries were examined by 20/30 MHz IVUS. The ultrasound cross-sections were compared to the corresponding radiologic (30 kV) and histologic cross-sections. RESULTS: Calcified lesions were imaged as bright echos with shadowing. In 13 cases of 161 calcified lesions were too small to detect by IVUS. In 5 ultrasonic sections the diagnosis "calcified lesion" could not be verified neither by radiology nor by histology. The sensitivity was 91.6%, the specificity was 94.7% and the accuracy was 93.0%. CONCLUSIONS: Because of the acoustic properties of calcium, calcified lesions can be detected accurately by IVUS. IVUS can generate new insights into the effect of plaque composition on the response to catheter therapies.

Aged↗

[Evaluating the measuring accuracy of intravascular ultrasound].

AIM: Intravascular ultrasound investigations are new tomographic imaging methods for evaluation of artery dimensions and wall morphology. The present study was performed to test accuracy and observer variability. METHOD: 3 plastic phantoms and 1 iliacan artery were assessed. The quantitative measurements were made by computerised 3D reconstruction. RESULTS: The plastic phantoms showed ultrasonically three layers of echogenic structures. An intimal fibrous thickening was seen in the iliac artery. The cross sectional diameters were ultrasonically overestimated by 12.6 +/- 5.6%. Due to the lower velocity of sound in water than in blood there were no significant differences to the true diameters. The intra- and interobserved variabilities were determined to 1.4 +/- 0.8% and 2.6 +/- 1.2%. CONCLUSIONS: Intravascular ultrasound provides a reproducible method for measuring vessel lumen diameters with excellent intraobserver and interobserver variabilities. For in vitro examinations the different velocities of sound in different media have to be taken into account.

Humans↗