PubMed Health⌕ Search

Biomedical subjects

M Menke

Publications and source records attributed to M Menke.

21 records · Page 2Linked to original sources

Alternative options for earning continuing education credit.

The HIM professional has traditionally been a highly motivated self-starter and a good detective. Today, the profile of the average HIM professional is that of a well-educated person, eager to learn more, who recognizes the necessity of keeping his or her skills up-to-date, and who is willing to take advantage of nontraditional options to further personal and professional goals. All these attributes can be put to good use in developing whatever alternative educational methods are appropriate to the most independent of persons.

Education, Continuing↗

Renal tolerance to nonhomogenous irradiation: comparison of observed effects to predictions of normal tissue complication probability from different biophysical models.

PURPOSE: A patient series was analyzed retrospectively as an example of whole organ kidney irradiation with an inhomogenous dose distribution to test the validity of biophysical models predicting normal tissue tolerance to radiotherapy. METHODS AND MATERIAL: From 1969 to 1984, 142 patients with seminoma were irradiated to the paraaortic region using predominantly rotational techniques which led to variable but partly substantial exposure of the kidneys. Median follow up was 8.2 (2.1-21) years and actuarial 10-year survival (Kaplan-Meier estimate) 82.8%. For all patients 3-dimensional dose distributions were reconstructed and normal tissue complication probabilities for the kidneys were generated from the individual dose volume histograms. To this respect different published biophysical algorithms had been introduced in a 3-dimensional-treatment planning system. RESULTS: In seven patients clinical manifest renal impairment was observed (interval 10-84 months). An excellent agreement between predicted and observed effects was seen for two volume-oriented models, whereas complications were overestimated by an algorithm based on critical element assumptions. CONCLUSIONS: Should these observations be confirmed and extended to different types of organs corresponding algorithms could easily be integrated into 3-dimensional-treatment planning programs and be used for comparing and judging different plans on a more biologically oriented basis.

Adult↗

Stereotactically guided fractionated radiotherapy: technical aspects.

A system for high precision radiotherapy in the head and neck region has been developed. The components of the system are a head mask connected to a stereotactic frame, a localization unit that can be used during CT- and MR-imaging and a stereotactic target positioner. Conformal precision radiotherapy is planned with a new treatment planning system (Voxelplan-Heidelberg). Three different multi-leaf collimator systems are used. An evaluation of the precision and accuracy of the head fixation system, which was performed with a photogrammetry system, is presented.

Head↗