PubMed Health⌕ Search

Biomedical subjects

M Mihic

Publications and source records attributed to M Mihic.

3 recordsLinked to original sources

The effect of acarbose on insulin sensitivity in subjects with impaired glucose tolerance.

OBJECTIVE: To study the effect of acarbose, an alpha-glucosidase inhibitor, on postprandial plasma glucose and insulin and insulin sensitivity in subjects with impaired glucose tolerance (IGT). RESEARCH DESIGN AND METHODS: Subjects with IGT were randomly treated in a double-blind fashion with placebo (n = 10) or acarbose (n = 8) at 100 mg t.i.d. for 4 months. All subjects were submitted before randomization and at the end of the study to a standardized breakfast and a 12-h daytime plasma glucose and plasma insulin profile, and insulin sensitivity was measured as steady-state plasma glucose (SSPG) using the insulin suppression test. RESULTS: While placebo had no effect on postprandial plasma glucose and plasma insulin incremental area under the curve (AUC) (3.03 +/- 0.5 vs. 3.76 +/- 0.6 mmol.h-1.l-1, P = NS; 1,488 +/- 229 vs. 1,609 +/- 253 pmol.h-1.l-1, P = NS), acarbose resulted in a significant reduction for both glucose (1.44 +/- 0.3 vs. 4.45 +/- 0.9 mmol.h-1.l-1, P = 0.002) and insulin (626.7 +/- 104.3 vs. 1,338.3 +/- 220.5 pmol.h-1.l-1, P = 0.003). The reduction in 12-h plasma glucose and insulin AUC on acarbose (11.2 +/- 2.1 mmol.h-1.l-1 and 7.5 +/- 0.7 nmol.h-1.l-1) was significantly greater than that on placebo (4.0 +/- 1.6 mmol.h-1.l-1 and 0.8 +/- 0.4 nmol.h-1.l-1) (P = 0.014 and 0.041). While SSPG was not affected by placebo (13.9 +/- 0.4 vs. 13.8 +/- 0.3 mmol/l; P = NS), it was significantly improved by acarbose (10.9 +/- 1.4 vs. 13.1 +/- 1.5 mmol/l, P < 0.004) and was also significantly different from placebo at 4 months (P < 0.02). CONCLUSIONS: It is concluded that in subjects with IGT, acarbose treatment decreases postprandial plasma glucose and insulin and improves insulin sensitivity. Acarbose may therefore be potentially useful to prevent the progression of IGT to NIDDM.

Acarbose↗

Effect of trimethoprim-sulfamethoxazole on blood insulin and glucose concentrations of diabetics.

Trimethoprim-sulfamethoxazole (TMP-SMX) caused no significant changes in the blood glucose or insulin concentrations of diabetic subjects treated by dietary measures alone or by insulin and diet. In only one of eight subjects receiving oral hypoglycemic agents for the control of diabetes did a significant immediate increase in immunoreactive insulin follow administration of TMP-SMX. In the same patient hypoglycemic symptoms were present after the agent had been taken for 14 days.

Administration, Oral↗

Computer-assisted insulin dosage adjustment.

We report our first experience with a new microprocessor device for assisting individuals with diabetes in the adjustment of insulin therapy. The computer weighs 200 g and can receive, store, and analyze patient-entered capillary blood glucose (CBG) data on an ongoing basis. Changes in the injected mixtures of short- and intermediate-acting insulins are recommended according to algorithms designed to bring the premeal CBG levels to any desired target value set by the physician. Throughout the present study, the premeal target glucose level was set to 110 mg/dl. Seven (type I) insulin-dependent diabetic individuals ranging in age from 11 to 43 yr were selected to participate in the first use of a BCMC (Better Control Medical Computers, Inc., Toronto, Ontario, Canada) computer on an outpatient basis. All subjects were concerned about diabetes control and were fully informed about as well as thoroughly practiced in the use of manual insulin dosage adjustment schemes, based on approximately equal to 4 times daily CBG estimation, as currently taught in our diabetes clinics. During the last 7 days of the control period of self-adjustment, their mean +/- SEM CBG levels (measured before breakfast, lunch, dinner, and bedtime snack) were, respectively, 178 +/- 20, 187 +/- 35, 208 +/- 22, and 207 +/- 13 mg/dl. Immediately after the control period they were given the device and were instructed in the procedure for entering glycemic data and following manufacturer's recommendations in regard to insulin dosages. This experimental period lasted 8 wk and the outcome was assessed as before. Thus, 8 wk after starting daily use of the instrument, all glycemic values measured as before had fallen significantly (P less than 0.005-0.05) closer to normal: 116 +/- 9, 110 +/- 6, 148 +/- 15, and 135 +/- 9 mg/dl, respectively. Concurrently there was also a significant (P less than 0.01) reduction in the variability of glycemia measured before the main meals.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗