Peritoneal blood flow: does it matter?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Milan.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We report on a family in which a mother and her 3 daughters have delayed psychomotor development and/or psychosis, hydrocephalus with white matter alterations, arachnoid cysts, skeletal anomalies consisting of brachydactyly, and Sprengel anomaly. Biochemical and cytogenetic analyses were normal on all 4 patients. The pattern of inheritance, clinical manifestations, and variability of expression suggest that this is a new hydrocephalus syndrome possibly transmitted as an X-linked dominant trait.
A total of 732 cases of omphalocele and 274 cases of gastroschisis was registered in 21 regional registers in Europe (EUROCAT registers) during the period 1980-1990. The total prevalence rates were 2.52 per 10,000 for omphalocele and 0.94 per 10,000 for gastroschisis. There was significant heterogeneity in total prevalence rates among regions for omphalocele. Consistently higher than average total prevalence rates of omphalocele were found in the five centers of the British Isles. This was in large part linked to the association between omphalocele and neural tube defects. A significant female excess among the cases of omphalocele associated with neural tube defects, in comparison with an insignificant male excess for other cases of omphalocele, was observed. Geographical differences in the total prevalence of gastroschisis are partly explained by differences in maternal age distributions in the populations surveyed. Omphalocele was an isolated malformation in 46% of cases; gastroschisis was isolated in 79% of cases. The average birthweight and gestational age of both isolated and multiply malformed cases of both omphalocele and gastroschisis were low, especially for multiply malformed cases, and to a greater extent for isolated gastroschisis than for isolated omphalocele. Prenatal diagnosis leading to termination of pregnancy was reported in 33.2% of omphalocele and in 26.5% of gastroschisis cases, demonstrating the considerable impact of current prenatal screening programs. On the basis of clinical manifestations, epidemiologic characteristics, and the presence and type of additional malformations, omphalocele and gastroschisis can be considered heterogeneous conditions.
Explore the source record for details and available documents.
Epidemiological and genetic variables for oral clefts were analysed for the years 1981-1989 in a case-control study of congenital malformations in the Emilia Romagna, Veneto, and Friuli regions, and in the Trento and Bolzano hospitals. Birth prevalence for all cases of cleft lip with or without cleft palate (CL(P)) was 8.2 per 10,000 births, and that for cleft palate only (CP) was 6.1 per 10,000. Coexisting abnormalities were found in 23% of CL(P) cases and in 43% of CP. No clusters in time or space were detected. For isolated clefts, a predominance of males among CL(P) and of females among CP was found; epilepsy was the only maternal risk factor correlated with clefts, and an association between clefting and consanguinity was found. Empirical recurrence risks were calculated in both isolated CL(P) and CP.
ICRP Publication 60 (1990) proposes a partially revised method to calculate effective dose, a quantity previously defined in ICRP Publication 26 (1977) as effective dose equivalent. The authors applied these two different approaches to calculate the effective dose equivalent and the effective dose, in the case of internal irradiations from the most common nuclear medicine investigations. The results show clear differences between the two examined quantities, even if the differences are not statistically significant.
Eight samples of human peritoneal tissue were obtained from patients undergoing hemicholectomy for cancer. An artery and a vein were cannulated and perfused with blood in vitro with a special circuit able to provide different perfusion pressures. Ultrafiltration and clearance studies were performed in these samples. Both ultrafiltration and small-solute clearances linearly correlated with the blood flow, demonstrating a strong dependence on this parameter. The peritoneal capillary showed a typical filtration pressure equilibrium with a constant filtration fraction at different blood flows. The results suggest that the blood flow may be a factor limiting the efficiency of peritoneal dialysis both in terms of mass transfer coefficients and maximal ultrafiltration rates.
Explore the source record for details and available documents.
Several patients undergoing chronic renal replacement therapy present problems related to their vascular access. Low blood flows and high rates of recirculation are common in such patients in which, for this reason, it becomes difficult to apply highly efficient techniques or techniques where diffusion and convection are combined as in hemodiafiltration. In these patients we studied the possibility of partially recirculating the blood in the extracorporeal circuit in order to increase the flow rate per single hollow fiber; we defined our system "double pass dialysis". We evaluated the system's efficiency in 12 patients during 24 dialysis sessions: 12 high flux dialysis sessions (without reinfusion) and 12 hemodiafiltration sessions (9 liters reinfusion). Different surfaces of polyacrylonitrile dialyzers were utilized (1.3-1.7-2.1 sqm) at 250 and 350 ml/min of blood flow with or without 100 ml/min of recirculation. During each dialysis session blood and dialysate samples were taken in order to calculate BUN, Creatinine, Phosphate and Inuline clearances from both the blood and dialysate side. The clearances of low molecular weight solutes were not really influenced by the artificial increase of the blood flow, but on the other hand, the clearances of higher molecular weight solutes increased from 10 to 30% during both high flux dialysis and hemodiafiltration with recirculation. This increase was evident mostly in hemodiafiltration suggesting that the cleaning effect on the membrane has a positive impact on the permeability. The good clinical results obtained with the double pass dialysis show that the system is safe and reliable and may become a valid support in critical situations in order to reach adequate dialysis treatment.
The endotoxin transfer across dialysis membranes has been investigated using specific in vitro circuits. Backdiffusion and backfiltration have been analyzed and most dialysis membranes have shown to be permeable to LAL positive substances. Synthetic membranes however display the better capacity of retention of these products despite their higher porosity and permeability. For such reason synthetic polysulfone ultrafilters are used as pyrogen filters to obtain ultrapure dialysate. We have investigated the characteristics of a polysulfone ultrafilter named Diaclean and manufactured by Amicon Ireland. The capacity of endotoxin retention has been investigated both in filtration and backfiltration modes on new and used ultrafilters. The capacity of endotoxin adsorption was investigated as well. Used ultrafilters appeared to maintain the retention capacity and the adsorption capacity up to 4 months of use. Only slight differences were noted from the baseline values (p = n.s.). The best adsorption capacity is always displayed by the outer layer of the membrane suggesting its best utilization in back filtration mode with tangential flow. No morphological changes were observed in the used membrane analyzed by scanning electron microscopy.
A new blood module for continuous renal replacement therapies has been utilized to perform CVVH in critically ill patients. The features of the new module named (HP300 and manufactured by Medica srl (Medolla, Modena) are the easy installation and transportability to the bedside, the simple and safe management and the continuous measurement of the pre and post filter pressure with automatic calculation of the end-to-end pressure drop inside the filter. The last feature permits to detect early malfunctions of the filter due to fibers clotting or due to the internal coating of the hollow fibers by plasma proteins. In both cases the efficiency of the treatment can be reduced because of a significant reduction of the ultrafiltration rates or a remarkable decay of the membrane permeability and solute sieving coefficients. In many cases this reduction is only detected when important effects on solute removal have already occurred. In our experience, the new module permitted the substitution of the filters when early malfunctions were detected and maximal treatment efficiency was therefore guaranteed over extended periods of time.
Ultrafiltration and pressure profiles in hollow fiber dialyzers with different hydraulic permeabilities have been investigated with a new scintigraphic method. Radiolabelled albumin macroaggregates, used as a nondiffusible marker molecule, were added to the blood in an in vitro circuit and circulated through cuprophan and polysulphon dialyzers. Since the marker molecule was too big to cross the dialysis membrane, its changes in concentration were assumed to occur in response to the variation of the blood water content (filtration or back-filtration). These changes in concentration, recorded by a gamma camera, were evaluated to establish the cumulative values of filtration and back-filtration and their relevant profiles along the length of the dialyzer. The achieved data were compared with the experimental values of ultrafiltration empirically measured and with the theoretical values predicted by a classic linear method. Two conditions were analyzed: A) the minimal filtration rate necessary to avoid back-filtration (critical filtration); and B) the condition of zero net filtration in which filtration equals back-filtration. The nuclear method proved to be extremely precise in predicting the ultrafiltration values and significantly more precise than the linear method, especially for the highly permeable dialyzer. The reason for that probably depends on the non-linear pressure and ultrafiltration profile observed with the scintigraphic pattern of the dialyzer. Viscosity changes and local variations in blood flow may in fact interfere with the pressure drop inside the hollow fibers and result in such a complex behavior. The other interesting aspect of this method is the possibility of accurate measurement of the amount of back-filtration that wouldn't be possible with simple calculations. In conclusion, the complex nature of the phenomena regulating the water fluxes in hollow fiber dialyzers requires more complex calculation than a simple linear model to achieve an accurate range of predictability.
The contamination of dialysis machines is an important risk factor for the spread of viral hepatitis in hemodialysis units. The use of reserved machines in separate rooms is a safe prophylactic measure.
Paired filtration dialysis (two-chamber haemodiafiltration) was evaluated as a short, highly efficient renal replacement therapy in 35 uraemic subjects belonging to three different dialysis centres. The study period was 1 year. Patients were divided into two groups according to their body-weight and drinking habits. The smaller patients underwent 150-min dialysis sessions three times weekly. The larger patients underwent 3-h treatments thrice weekly. The treatment was adequate in all patients according to the KT/V criteria of adequacy. The intradialytic symptomatology was remarkably low and the treatments were well tolerated in all patients. The study confirms the reliability of paired filtration dialysis as a short dialysis technique. In some patients 150 min may be insufficient to achieve an adequate dialysis efficiency and 180 min may be required for the majority of the population.
Explore the source record for details and available documents.
Explore the source record for details and available documents.