PubMed Health⌕ Search

Biomedical subjects

M Moyers

Publications and source records attributed to M Moyers.

6 recordsLinked to original sources

Proton dosimetry intercomparison based on the ICRU report 59 protocol.

BACKGROUND AND PURPOSE: A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors. MATERIALS AND METHODS: Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations. RESULTS: The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type. CONCLUSIONS: Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.

Algorithms↗

Proton-beam radiotherapy for early-stage lung cancer.

STUDY OBJECTIVE: A prospective study was undertaken to assess the efficacy and toxicity of conformal proton-beam radiotherapy for early-stage, medically inoperable non-small cell lung cancer. DESIGN: Eligible patients had clinical stage I to IIIa non-small cell lung cancer and were not candidates for surgical resection for medical reasons or because of patient refusal. Patients with adequate cardiopulmonary function received 45 Gy to the mediastinum and gross tumor volume with photons with a concurrent proton boost to the gross tumor volume of an additional 28.8 cobalt gray equivalents (CGE). Total tumor dose was 73.8 CGE given over 5 weeks. Patients with poor cardiopulmonary function received proton-beam radiotherapy to the gross tumor volume only, with 51 CGE given in 10 fractions over a 2-week period. RESULTS: Thirty-seven patients were treated in the study from July 1994 to March 1998. Clinical staging of patients was as follows: stage I, 27 patients; stage II, 2 patients; and stage IIIa, 8 patients. Eighteen patients received a combination of protons and x rays, while 19 patients received proton-beam radiation only. Follow-up of evaluable patients ranged from 3 to 45 months, with a median of 14 months. Two patients in the proton and photon arm developed pneumonitis that resolved with oral steroids; otherwise, no significant toxicities were encountered. The actuarial disease-free survival at 2 years for the entire group was 63%; for stage I patients, disease-free survival at 2 years was 86%. Local disease control was 87%. CONCLUSION: Preliminary results from this study indicate that proton-beam radiotherapy can be used safely in this group of patients. Disease-free survival and local control appear to be good and compare favorably with published reports utilizing conventional photon irradiation.

Aged↗

Proton therapy for pediatric cranial tumors: preliminary report on treatment and disease-related morbidities.

PURPOSE: Accelerated protons were used in an attempt to limit treatment-related morbidity in children with tumors in or near the developing brain, by reducing the integral dose to adjacent normal tissues. METHODS AND MATERIALS: Children treated with protons at Loma Linda University Medical Center between August 1991 and December 1994 were analyzed retrospectively. Twenty-eight children, aged 1 to 18 years, were identified as at risk for brain injury from treatment. Medical records, physical examinations, and correspondence with patients, their parents, and referring physicians were analyzed. The investigators tabulated post-treatment changes in pre-treatment signs and symptoms and made judgments as to whether improvement, no change, or worsening related to disease or treatment had supervened. Magnetic resonance images were correlated with clinical findings and radiographic impressions were tabulated. RESULTS: Follow-up ranged from 7 to 49 months (median 25 months). Four instances of treatment-related morbidity were identified. Forty-one instances of site-specific, disease-related morbidity were identified: 15 improved or resolved and 26 remained unchanged after treatment. Four patients had radiographic evidence of local failure. Three of these patients, including two with high-grade glioma, have died. CONCLUSION: Early treatment-related morbidity associated with proton therapy is low. Tumor progression remains a problem when treating certain histologies such as high-grade glioma. Escalating the dose delivered to target volumes may benefit children with tumors associated with poor rates of local control. Long-term follow-up, including neurocognitive testing, is in progress to assess integral-dose effects on cognitive, behavioral and developmental outcomes in children with cranial tumors.

Adolescent↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

Magnetic resonance imaging as a monitor of changes in the irradiated rat brain. An aid in determining the time course of events in a histologic study.

RATIONALE AND OBJECTIVES: Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI device was used to monitor the response of the rat brain after irradiation as a possible indicator for histologic injury as a function of time and dose. METHODS: Single-dose fractions of protons were delivered to the left brain of 25 adult Sprague-Dawley rats. T1- and T2-weighted images were obtained using a 1.5-T MRI device via a 12-cm diameter coil at 4- to 6-week intervals after irradiation. Coronal images were evaluated by visual inspection and relaxation maps comparing the control and irradiated hemispheres. Histologic review was conducted on all rats' brains after death. RESULTS: Proton irradiation was delivered successfully to only the left brain of the animals. Histologic review confirms the location and extent of tissue damage demonstrated on MRIs obtained in vivo. Statistically significant differences were seen in the T2-weighted relaxation times in the irradiated cerebral hemisphere compared with the unirradiated hemisphere. CONCLUSION: The proton hemibrain rat model can be used to test treatment schedules of irradiation for central nervous system response using MRI to noninvasively document early and late effects within the same animal.

Animals↗

Application of solid state detectors for dosimetry of therapeutic proton beams.

A PTW Riga diamond detector and LiF TLDs have been evaluated for use in proton beam dosimetry by comparing results of proton beam calibration with those obtained using thimble ionization chambers. The thimble ionization chambers were calibrated in terms of exposure while the TLDs and diamond detector were calibrated in terms of absorbed dose in a 60Co beam. Absorbed doses to muscle in proton beams for ionization chambers were derived using the TG 20 charged particle protocol. Absorbed doses to muscle for solid state detectors were derived using absorbed dose proton beam quality correction factors. Differences between the derived doses for ionization chambers and solid state detectors were found to be within the uncertainties of measurements: 4.5% for ionization chambers and 5% for solid state detectors.

Cobalt Radioisotopes↗