PubMed Health⌕ Search

Biomedical subjects

M Munz

Publications and source records attributed to M Munz.

At least 19 recordsLinked to original sources

A novel TITF-1 mutation causes benign hereditary chorea with response to levodopa.

Presented is a pedigree with infancy-onset benign hereditary chorea (BHC) caused by a novel nonsense mutation in exon 3 (523G-->T, E175X) of the TITF-1 (Nkx2.1) gene. Four confirmed mutation carriers showed the typical movement disorder of BHC and congenital hypothyroidism. Surprisingly, treatment with levodopa improved gait dramatically and reduced chorea in two patients. Dopaminergic drugs should be considered a useful therapeutic option in BHC.

Child↗

[Medical informatics in obstetrics and gynecology - the actual challenge?].

There is common agreement about the importance of information management systems in obstetrics and gynecology. Those systems are necessary tools for medical quality management and are essential for the actual preparation for the age of the "diagnosis related groups" that will be introduced in Germany next year. Nevertheless there are only small scientifically activities to improve information management systems and to evaluate their performance. Great efforts are necessary to develop new features and not to loose the conflict between the needs of the physicians and their patients and the needs and demands of hospital administrative authorities.

Female↗

Total body and regional bone mineral densitometry (BMD) and soft tissue measurements: correlations of BMD parameter to lumbar spine and hip.

Bone loss in men and women seems to differ according to the skeletal regions or particular areas being evaluated. Dual energy X-ray absorptiometry (DXA) is the method of choice for measuring total body and regional bone mineral area density (BMD). The aim of the study was to evaluate the importance of DXA measurements of total body in relation to lumbar spine and hip in different scan beam designs. In 300 patients, ages 43-80 years, lumbar spine, hip, total body and regional bone mineral area density, and soft tissue measurements were performed on all subjects in the supine position on a QDR 2000 using single beam (SB) and fan beam (FB). Short-term precision errors were 0.7% (SB) and 1.2% (FB) for BMD total of the total body and between 1.2% and 8.0% for soft tissue measurements. All mid-term precision errors of BMD total, right and left leg, and pelvis were below 2.0% with SB and FB, whereas precision errors of thoracic and lumbar spine varied depending on the scan mode being applied. In contrast, all mid-term precision errors of soft tissue measurements were greater (2.6-11.0%). All SB values of BMD and soft tissue measurement were significantly higher than FB values, except for BMD values of the head, thoracic spine, and pelvis. Furthermore, BMD total of the total body scan correlated significantly (P < 0. 001) with all subregional parameters with best "r"-values (0.86-0. 92) for the right and left leg in SB and FB design. In addition, there were excellent correlations (r > 0.94, P < 0.001) between the right and left legs (SB and FB) or arms (SB). There were also highly significant correlations between the lumbar spine (or hip) and total body, being best for the subregional thorax. Our data demonstrate short-and mid-term precision errors of BMD with reproducible results for most areas in SB and FB design, whereas soft tissue measurements vary depending on the area being measured. Furthermore, there is a close relationship between BMD values of total body total and subregional parameters and lumbar spine and hip scans, respectively.

Absorptiometry, Photon↗

Placement of deep brain stimulators into the subthalamic nucleus.

We present our technique for deep brain stimulation (DBS) of the subthalamic nucleus (STN) and include information which may be helpful in general DBS. With the patient in a stereotactic head frame, the anterior and posterior commissures are identified on SPGR-sequence magnetic resonance imaging (MRI). STN coordinates are based on a stereotactic brain atlas at 12 mm lateral, 2 mm posterior and 5 mm caudal to the midcommissural point. Surgical navigation software allows for planning of the trajectory. Electromyography is used to quantitatively measure tremor responses to macrostimulation. Permanent lead placement is confirmed with intraoperative fluoroscopy and postoperative MRI.

Brain Mapping↗

Vocal tremor reduction with deep brain stimulation.

We present a case illustration of the significant effect that deep brain stimulation (DBS) of the thalamus can have on vocal tremor. A 72-year-old female with a history of essential tremor was noted preoperatively to have a moderate vocal tremor (3 on a scale of 1-5). Following bilateral DBS of the thalamus, the vocal tremor rating improved to 1. Acoustic analysis demonstrated her vocal tremor to be affecting the amplitude of her voice at 5.58 Hz preoperatively, at 1. 93 Hz postoperatively with both leads on and at 1.54 Hz with only the left lead on. A videotaped endoscopic view of the patient's vocal cords (presented at the 1999 ASSFN meeting) clearly illustrated the dramatic changes apparent in the vocal tremor when the stimulators were turned on and off.

Aged↗

Inhibition of voluntary activity by thalamic stimulation in humans: relevance for the control of tremor.

The motor effects of stimuli delivered through four-channel, quadripolar macroelectrodes chronically implanted in the ventrolateral thalamus were studied in 20 awake cooperating human subjects. Single stimuli could inhibit voluntary contraction of the contralateral first dorsal interosseous muscle (FDI) for up to 200 ms. The inhibition was often followed by a rebound facilitation or by oscillatory activity. This inhibition appeared to arise from the ventrolateral thalamus and could not be obtained in other patients by stimulation of the periventricular grey matter (PVG), the globus pallidus internus (GPI), or the subthalamic nucleus (STN). The neural elements activated by the stimulus had a short chronaxie and a short refractory period, implying that they were large-diameter axons. Similar effects were obtained from each of the four electrodes in the row, suggesting that this fiber system lay parallel rather than perpendicular to the implanted macroelectrode. The inhibition resulting from a single stimulus was diminished by a prior stimulus or train of stimuli. A continuous train of stimuli produced inhibition for only the first 200 ms. We propose that the thalamic stimulus activates a neural network which includes thalamic relay cells and neurons of the thalamic reticular nucleus and that the inhibition of thalamic relay cells habituates with repeated stimuli. It has been suggested that parkinsonian rest tremor results from synchronization of the oscillatory activity of this network. If this is the case, continuous thalamic stimulation might disrupt this oscillation by diminishing the inhibitory phase.

Brain Mapping↗

Deep brain stimulation and thalamotomy for tremor compared.

Deep brain stimulation (DBS) and thalamotomy are both capable of abolishing tremor. However, no technique is perfect and if thalamotomy proves inadequate so that tremor recurs, presumably because of suboptimal lesion location, the only option is to repeat the thalamotomy. With DBS all that has been necessary to date is to change the parameters of stimulation. Similarly with complications such as the "cerebellar" ones and paraesthesiae. If these occur after thalamotomy one can only wait and hope that they will subside and they do not always do so. With DBS, changing the parameters in the authors' patients has so far been successful in eliminating them. DBS, like thalamotomy is very effective for controlling tremor in Parkinson's disease (PD) and essential tremor (ET) and for improving dexterity in ET, but both techniques are less useful for the control of dopa dyskinesia, Parkinsonian rigidity, or impaired dexterity in PD, though DBS may be better than thalamotomy for the latter condition. On the other hand, both DBS and thalamotomy are very effective in improving dexterity in PD and ET may depend upon the fact that in PD bradykinesia is a major component, whereas in ET only the tremor is. The advantages of DBS over thalamotomy have to be weighed against the peculiar risks of DBS and of course, its cost.

Adult↗

Bone mineral density of opposing hips using dual energy X-Ray absorptiometry in single-beam and fan-beam design.

Bone densitometry focuses on bone mineral area density (BMD in g/cm2) of the proximal femur and spine in anterior-posterior (AP) projections. Artifacts, such as osteoarthritis and osteophytic calcifications (OC) influence spine BMD, especially in AP scans. If only two sites are measured, as is usual in clinical practice, there may be advantages to measuring both femora rather than one femur and the spine. This would not be useful, however, if there was strong symmetry between the two sides. Furthermore, fan beam (FB) techniques have become available for measuring BMD with less data acquisition time. We compared densitometry of opposing femora in 421 patients (369 women, mean age 59.0 +/- 4.8; 52 men, mean age 56.9 +/- 7.4) using dual-energy X-ray absorptiometry (DXA): both single-beam (SB) and FB modes were evaluated. The precision errors in vivo (short- and midterm) of total BMD were 0.7% for both SB and FB. The total BMD and BMC of the left hip (0.817 +/- 0.124 g/cm2, 31. 3 +/- 6.4 g) were significantly (P < 0.001) higher (2-3%) than the corresponding values of the right hip (0.801 +/- 0.125 g/cm2, 30.3 +/- 6.3 g) in both SB and FB (left BMD 0.802 +/- 0.117 g/cm2, BMC 30. 0 +/- 6.2 g versus right BMD 0.795 +/- 0.117 g/cm2, BMC 29.3 +/- 6.3 g) modes. However, BMD of the femoral neck and Ward's triangle were not significantly (P > 0.05) different between the two sides. The FB results were generally 2% lower than SB results. There were highly significant (P < 0.001) correlations (r > 0.9) between both hips using both SB and FB. For diagnostic procedures and longitudinal studies, one should consider that there are bilateral differences of femur BMD, as well as differences between FB and SB scan modes.

Absorptiometry, Photon↗

Chronic electrical stimulation of the gasserian ganglion for the relief of pain in a series of 34 patients.

The use of an implanted system for chronic electrical stimulation of the gasserian ganglion for relief of facial pain was described in 1980 by Meyerson and Håkansson. Between 1982 and 1995, the senior author (R.R.T.) performed gasserian ganglion stimulation in 34 patients for the relief of chronic medically intractable facial pain. The etiology of pain was peripheral damage to the trigeminal nerve in 22 patients (65%), central (stroke) damage in seven (21%), postherpetic neuralgia in four (12%), and unclassifiable cause in one (3%). All patients received a trial of transcutaneous stimulation (Stage 1). Successful trials in 19 patients (56%) were followed by implantation of a permanent system (Stage II). Trial and postimplantation stimulation were deemed successful when there was a reduction of pain by at least 50% whenever the stimulator was on. Success rates varied from five (71%) of seven patients for central pain to five (23%) of 22 for peripheral pain and none (0%) of four for postherpetic neuralgia. The median follow-up duration in successful cases was 22.5 months. Infections occurred in seven patients, all of whom had undergone Stage II treatment. Infections were more frequent when the stimulating electrode from Stage I was left in place for Stage II (six [43%] of 14) than when completely new hardware was used and prophylactic antibiotic drugs were administered (one [20%] of five). Other complications included iatrogenic injury to the trigeminal nerve or ganglion in three cases (9%), transient diplopia in two (6%), increased pain in two (6%), and various technical problems in 10 (29%). It is concluded that pain of central origin (stroke) is the type most likely to be relieved by this procedure. This finding is new, as the few other clinical series reported to date contain no patients with this type of pain. The risk of infection seems to be lower when completely new hardware is used for Stage II and prophylactic antibiotic drugs are administered.

Antibiotic Prophylaxis↗

Evaluation of dual-energy X-ray absorptiometry bone mineral measurement--comparison of a single-beam and fan-beam design: the effect of osteophytic calcification on spine bone mineral density.

Dual energy X-ray absorptiometry (DXA) using a single-beam (SB) design is a well-established procedure for measuring bone mineral area density (BMD). Recently, fan beam (FB) techniques have become available to measure BMD. We evaluated the QDR1000 and QDR2000 densitometers with regard to precision and cross-compared values using single beam (SB) and FB techniques. To study the effect of osteoarthritic changes on bone measurement (BMC in g) and bone mineral area density (BMD in g/cm2), both parameters were measured in patients with and without osteophytic calcifications (OC) of the lumbar spine. Precision errors for BMD in vitro over 1 and 6 months using the QDR2000 were 0.4% and 0.6% for SB and 0.5% and 0.7% for the three FB modes. For QDR1000 only SB is available. Using this scan mode, the BMD difference (delta = 0.1%) in vitro between QDR1000 and QDR2000 was not significant. The short-term (same day) reproducibility of BMD in vivo was 0.85% for SB mode and 1.1% for FB scan mode (n = 33). The midterm (1 month) precision errors were 0.9% for SB and 1.5% for FB (n = 11). The spine BMD of 751 patients from our outpatient clinic and department of rheumatology was 1.7% lower with FB than with SB (0.878 +/- 0.137 versus 0.888 +/- 0.146 g/cm2). Lower (1.8%) BMD values were also found in the hip with FB compared to SB (0.805 +/- 0.111 versus 0.821 +/- 0.111 g/cm2). There was a highly significant (P < 0.00001) correlation between SB and FB on the spine (r = 0.99) and hip (r = 0.98) using the QDR2000. Correlations found QDR1000 and QDR2000 were lower on the spine (r = 0.97) and hip (r = 0.93).(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Lateral spine dual-energy X-ray absorptiometry bone mineral measurement with fan-beam design: effect of osteophytic calcifications on lateral and anteroposterior spine BMD.

Recently, fan beam (FB) designs have been made available by several manufacturers (Aloka, Hologic Lunar and Sophar) to measure lumbar spine bone mineral area density (BMD) in both an anteroposterior (AP) and a lateral projection. The present study was performed to evaluate some characteristics of a new dual energy X-ray absorptiometry (DXA) system for supine lateral scans in normals and to study possible advantages for patients with osteophytic calcifications (OC). The precision errors of in vitro and in vivo measurements were estimated by an anthropomorphic phantom and in healthy volunteers. To study the effect of osteoarthritic changes on AP and lateral DXA measurements, BMC (bone mineral content) and BMD were measured in age-matched women (n = 150) with and without OC. Precision errors for lateral BMD in vitro over 1 and 6 months were 0.58/0.67% (slow/fast scan modes) and 0.67/0.77% (slow/fast scan modes), respectively. The short- and mid-term reproducibility of BMD values were 2% and 3.5%, respectively, using the compare function (3.5% and 7.5%, respectively, without the compare facility). The analysis of women with and without OC (n = 150) demonstrated higher mean values for AP BMD (0.892 +/- 0.145 g/cm2) in patients with OC (n = 75) than in normals (0.836 +/- 0.135 g/cm2, n = 75, difference 6.3%). For lateral scans, BMD differed to a minor degree (3.1%) in patients with OC (0.629 +/- 0.133 g/cm2) compared with normals (0.610 +/- 0.117 g/cm2). Corresponding results were obtained in fast FB mode. Furthermore, we found significant (P < 0.0001) correlations between BMD in lateral and AP scans in patients without OC (r = 0.63) and in patients with OC (r = 0.57). Although the FB design facilitated fast AP and lateral scans, the higher precision errors of lateral scans could limit its application in longitudinal studies. The use of compare function should be recommended. However, BMD of lateral scans was less influenced by OC.

Absorptiometry, Photon↗

Interurban migration and the dynamics of a system of cities: 1. The stochastic framework with an application to the French urban system.

"A stochastic framework for the modelling of interurban migration is presented. The model is an extension of a recently developed master-equation approach to interregional migration. The population dynamics of the French urban system, described by a set of 78 cities, is investigated within the period 1954-82. The importance of synergy effects (self-reinforcing collective effects) as well as socioeconomic macrovariables for the understanding of urban dynamics becomes obvious. A forecasting of urban dynamics...[up to the year 2002 confirms] this result and [gives] further insight into the nested structure of urban systems."

Demography↗

Otitis media and CNS complications.

Intracranial complications from otitis media can be quite devastating to the patient if an early diagnosis is not made. Patients may develop meningitis, venous sinus thrombosis or cranial nerve palsies, as well as intracranial abscess. The presenting features in such cases may be subtle and include headache, nausea, vomiting, personality changes and signs of increased intracranial pressure as well as focal neurological deficits. A case of intracranial brain abscess is presented in a patient with a history of chronic otitis media with cholesteatoma. Delay in the diagnosis of intracranial complications of otitis media can lead to improper treatment with increased morbidity and mortality. The etiology and treatment of complications affecting the CNS is discussed.

Brain Abscess↗

Settlement formation. Part I: a dynamic theory.

"The dynamic process of settlement formation is a fundamental issue in regional science. Our proposed model integrates the economic and migratory sectors in terms of endogenous variables in order to describe the evolution of continuous population distributions as a self-organising process.... The purpose...is to show that under strongly idealised conditions, a population consisting of different subpopulations with different economic activities will evolve into a differentiated population pattern. Each member of the subpopulations has the possibility to migrate between locations stimulated by rational economic reasons. This idea, which seems almost self-evident on the level of qualitative argumentation, [will] be cast into a mathematically self-contained quantitative dynamic model."

Behavior↗

Spinal synovial cyst: case report using magnetic resonance imaging.

The case of a 65-year-old woman who developed a spinal synovial cyst at the L4-5 disk space is reported. Her clinical signs and symptoms are presented. A comparison among her preoperative myelogram, computed tomography scan, and magnetic resonance imaging showed magnetic resonance imaging to be more accurate in detailing both the intraoperative and pathological findings.

Aged↗