PubMed Health⌕ Search

Biomedical subjects

M Musci

Publications and source records attributed to M Musci.

At least 19 recordsLinked to original sources

Orthotopic heart transplantation with concurrent coronary artery bypass grafting or previous stent implantation.

We describe three cases of donor hearts with preexisting coronary artery disease already diagnosed prior to transplantation: two were treated by coronary artery bypass grafting during the transplant procedure and one by angioplasty with stenting during the donor screening angiography. All three donor organs would otherwise have been rejected, depriving potential recipients of organ transplantation. All patients had an uneventful post-operative course with follow-up completed 22, 40 and 43 months after orthotopic transplantation showing patency of the stent and bypass grafts in the early (1 and 9 months) and late (22, 24 and 37 months) coronary angiography. Our results suggest that in this era of acute organ shortage donor hearts requiring bypass or stenting, which form a small but significant donor subgroup, can be used effectively and safely when matched to the recipients' age and medical condition.

Aged↗

Use of experimental design for the purge-and-trap-gas chromatography-mass spectrometry determination of methyl tert.-butyl ether, tert.-butyl alcohol and BTEX in groundwater at trace level.

An efficient method for the simultaneous determination of methyl tert.-butyl ether, tert.-butyl alcohol, benzene, toluene, ethylbenzene and xylene isomers in groundwater by purge-and-trap-gas chromatography-mass spectrometry was developed and validated. Experimental design was used to investigate the effects of temperature of extraction, time of extraction and percentage of salt added to the water samples. Regression models and desirability functions were applied to find the experimental conditions providing the highest global extraction yield. Validation was carried out in terms of limits of detection (LOD), limits of quantitation (LOQ), linearity and precision. LOD values ranging from 2.6 to 23 ng l(-1) were achieved, whereas linearity was statistically verified over two orders of magnitude for each compound. Precision was evaluated testing two concentration levels. Good results were obtained both in terms of intra-day repeatability and intermediate precision: RSD% lower than 4.5% at the highest concentration and lower than 13% at the lowest one were calculated for intra-day repeatability. A groundwater sample suspected of contamination by leaking underground petroleum storage tanks was analysed and some of the analytes were detected and quantitated.

Benzene Derivatives↗

Surgical management of acute aortic root endocarditis with viable homograft: 13-year experience.

OBJECTIVE: Cryopreserved homograft valves have been used for acute infective aortic root endocarditis with great success but it is compounded by its availability in all sizes. The long-term clinical results of geometric mismatched homografts are not well defined and addressed. METHODS: Over a 15-year period (April 1986-June 2001), 816 patients presented with active infective endocarditis. One hundred and eighty-two of the patients aged between 9 and 78 years (mean: 51.0 +/- 1.13 years) consisting of 142 males and 40 females received homograft aortic valves. One hundred and ten patients were in NYHA functional class III and 72 in class IV and in cardiogenic shock. Of the patients, 2.7% suffered from septic embolism. One hundred and twenty-four (68.1%) patients presented with periannular abscesses and 58 (31.9%) with no abscess while 107 native valve (NVE) and 75 prosthetic valve (PVE) endocarditis were diagnosed preoperatively by transesophageal echocardiography (TEE) and confirmed intraoperatively. Freehand subcoronary implantation (FSCI) was used in 106 patients and root replacement in 76 patients. RESULTS: The operative death was 8.5% and for patients in NYHA functional class IV and in cardiogenic shock was 14.5%. Late mortality rate was 7.9%. Patient survival after discharge from hospital at 1 year was 97% and at 10 years was 91%, respectively. Thirty-one (22.1%) patients underwent reoperation after 1.7 years (mean) with two deaths (6.4%). Early (< or = 60 days) and late reinfection rate was 2.7 and 3.6%, respectively. Freedom from reoperation for matched and undersized homografts at 10-13 years was 85 and 55%, respectively. The univariate model identified undersized homograft (P=0.002), FSCI (P=0.09) and reinfection (P=0.0001) as independent risk factors for developing early and late valve dysfunction resulting in reoperation and homograft explant. CONCLUSION: Early aggressive valve replacement with homograft for active infective aortic root endocarditis with periannular abscesses is more successful than delayed last resort surgery. Homografts exhibit excellent clinical performance and durability with a low rate of reinfection, if properly inserted. Undersized homograft is an incremental risk factor for early and late reoperation.

Adolescent↗

Geometric mismatch between homograft (allograft) and native aortic root: a 14-year clinical experience.

OBJECTIVES: We evaluated the effect of homograft/native aortic root geometric matching and mismatching on valve survival and myocardial remodeling. METHODS: Between January 1, 1987 and March 2000, a total of 292 patients, aged 1.5-78 years (mean, 46.2 years), underwent freehand subcoronary aortic valve (AVR; n=207) and root (ARR; n=85) replacement with matched and mismatched cryopreserved homografts. All patients had pre- and postoperative two-dimensional Doppler echocardiographic studies. Two-hundred and forty-three survivors, excluding children with complete data on sizing, were followed at a total follow-up time of 1269 patient-years. Seventy percent received matched and 30% received mismatched aortic homografts. The homograft valve sizes ranged from 19 to 28 mm. RESULTS: Hospital death for elective first operation was 2.3%, and late death after a mean follow-up of 52 months was 7.9%. The patient survival at 14 years was 92+/-2%. By linear regression analysis, matched homografts were equal to or 1-2 mm less than the native aortic annulus (r(2)=0.73). The valve survival in patients with AVR and ARR was 72+/-4 and 80+/-8% at 14 years, respectively. The freedom from reoperation was 92+/-5, 77+/-4 and 48+/-10% at 14 years for matched, oversized and undersized homografts, respectively (P=0.001). The postoperative cardiac index of patients with 22 and 24 mm homografts was 3.8-4.1 l/m(2), and there was a regression of the left ventricular mass and end-diastolic diameter (P=0.001). CONCLUSIONS: The aortic homograft offers an excellent long-term clinical result. A mismatched homograft is a risk factor for postoperative aortic incompetence, reinfection with pseudoaneurysmal formation and reoperation for the freehand subcoronary implantation technique during the first 7 years of the postoperative period. It is prudent therefore to avoid mismatched homografts and use rather a properly sized stentless xenograft if a root replacement is not indicated.

Adolescent↗

Prevention of venous graft sclerosis with clopidogrel and aspirin combined with a mesh tubing in a dog model of arteriovenous bypass grafting.

OBJECTIVE: to investigate the effect of clopidogrel combined with aspirin or aspirin alone on fibromyointimal hyperplasia (FIMH) in a bypass model with native vein grafts (NVG) and biocompound grafts (BCG). DESIGN: twelve Beagle dogs were randomised into two equal groups. In each animal NVG and a BCG were interposed in the common carotid arteries. Postoperatively, Group 1 received clopidogrel (200 mg/d) and aspirin (100 mg/d) and Group 2 received aspirin (100 mg/d) alone. METHODS: the BCG was constructed by sheathing the ipsilateral jugular vein with highly flexible metal mesh tubing. After 30 days the grafts were harvested and pressure fixed. FIMH was determined by morphometry. RESULTS: the average wall thickness of the BCG was significantly lower than that of the NVG in both groups (0.26 (SD)0.02 mm vs 0.47 (SD)0.15 mm, p = 0.04 and 0.28 (SD)0.05 mm vs 0.70 (SD)0.29 mm, p = 0.01, respectively). For BCG treated with aspirin, the wall cross section area was lower (5.0 (SD)0.6 mm(2)vs 9.1 (SD)3.3 mm(2), p = 0.02) and the lumen larger (25.2 (SD)5.9 mm(2)vs 9.7 (SD)3.4 mm(2), p < 0.01) than for the NVG. There was also a difference in the lumen cross section area of the NVG, which was larger after combined therapy with clopidogrel and aspirin (17.9 (SD)7.8 mm(2)vs 9.7 (SD)3.4 mm(2), p = 0.04). CONCLUSIONS: in this dog model the sheathing of vein grafts effectively prevents FIMH following bypass surgery. Clopidogrel is effective in NVG.

Animals↗

A comparison of prototype compound parabolic collector-reactors (CPC) on the road to SOLARDETOX technology.

Solar photocatalytic detoxification of non-biodegradable chlorinated hydrocarbon solvents (NBCS) is carried out in different concentrating and non concentrating devices using TiO2 as a photocatalyst fixed on the inner surface of the reaction tubes or as a slurry catalyst which has to be removed from the treated water. The reaction is most effective using 200 mg/l of TiO2 as a slurry in a non concentrating CPC reactor. The concentrating parabolic trough reactor has a poor activity because of its minor irradiated reactor surface. Catalyst coated glass tubes are less efficient then the used slurry catalyst. Their advantage is that no catalyst has not to be removed from the treated water and there is no loss of activity during treatment. Yet their physical stability is not sufficient to be competitive to the slurry catalyst. Nevertheless the degradation results are very promising and will possibly lead to commercial applications of this technology.

Catalysis↗

Spectrophotometric and coulometric detection in the high-performance liquid chromatography of flavonoids and optimization of sample treatment for the determination of quercetin in orange juice.

The capabilities of spectrophotometric and electrochemical detection techniques were investigated for the high-performance liquid chromatographic determination of flavonoids. Liquid chromatographic analyses were performed on eleven compounds belonging to three different classes of flavonoids: flavanone glycosides, flavone and flavonol aglycones. Separation of all compounds examined was carried out under reversed-phase conditions on a C18 narrow-bore column for UV detection, whereas for electrochemical detection, a C18 standard-bore column was used. UV analyses were carried out at 280 nm for flavanones and at 265 nm for flavones and flavonols, whereas controlled-potential coulometric measurements were performed using a porous graphite electrode. Analytical performances of the methods were compared in terms of linearity, limits of detection (LODs) and precision. Linearity over two orders of magnitude and LODs at low-ppm levels (0.06-1 mg/l) were demonstrated for all techniques considered. Instrumental precision in terms of relative standard deviation was found to be between 0 and 5% for the liquid chromatography (LC)-UV system and between 0.6 and 10% for the LC-electrochemical detection (ED) system. The methods developed were applied to the analysis of flavanones and flavonols in a real sample, such as an extract of orange juice. Even though quercetin glycoside is mostly present in orange juice as rutin, other different glycosides of this flavonol could be present; on this basis, the hydrolysis of all glycosides to aglycone allows one to obtain more accurate data on the flavonol concentration in orange juice. To avoid sample degradation and to increase extraction efficiency, quercetin hydrolysis was optimized using a central composite design to investigate the effects of acid concentration and hydrolysis time on extraction recovery.

Beverages↗

Surgical treatment of a chest-wall penetrating left ventricular pseudoaneurysm.

This report describes the treatment of a patient who developed a chest-wall penetrating pseudoaneurysm 3 years after coronary bypass grafting and after the resection of a lateral wall left ventricular aneurysm twice. The patient presented with a pulsatile tumor in the left submammilar region. Surgery was done in deep hypothermia, with femoro-femoral cannulation and via a left anterolateral thoracotomy. The perioperative course was uneventful and the patient is still well 5 years after surgery.

Aged↗

The biocompound method in coronary artery bypass operations: surgical technique and 3-year patency.

BACKGROUND: Complete arterial revascularization may be unsafe in patients with a high operative risk. In patients with varicose ectatic veins, the biocompound technique, which uses unsuitable autologous veins, enables the surgeon to influence the bypass graft wall stress levels and diameter. This report summarizes the 3-year patency of 53 patients, the survival rate of 200 patients, and operative technical considerations. METHODS: Biocompound grafts were used for aortocoronary bypass in 200 patients who were considered inappropriate subjects for complete arterial revascularization and who had unsuitable saphenous veins. RESULTS: The mortality rate (30 days) of 200 patients was 3.5%. The 3-year survival rate was 88.5%. The patency rate of the left internal thoracic artery (LITA) after 3 years was 97.3%, of the native vein was 68.7%, and of the biocompound graft was 68.3%. The LITA showed a superior patency rate (p = < 0.05). CONCLUSIONS: The LITA is the first choice in coronary bypass operation. The biocompound technique is a reliable method to achieve complete revascularization in patients with a lack of suitable saphenous veins.

Aged↗

Tricuspid valve dysfunction and surgery after orthotopic cardiac transplantation.

OBJECTIVE: The study examines the prevalence of tricuspid regurgitation and biopsy-induced flail tricuspid leaflets after orthotopic heart transplantation and evaluates the results of the tricuspid valve surgery. METHODS: By a computerized search of the databases 647 of 889 patients who survived heart transplantation for more than 30 days were identified for this study. The primary tool for rejection monitoring in our institution is the daily observation of intramyocardial ECG (IMEG) based on day-by-day changes of the maximal QRS complex amplitude. Endomyocardial biopsy with 45-cm-long sheath bioptome was performed only in doubtful IMEG and echocardiographic data and at times of annual routine heart catheterization. Tricuspid regurgitation was diagnosed clinically and by echocardiography as mild, moderate and severe. Eleven patients received prosthetic valve replacements (four bioprostheses and seven mechanical valves) and six patients underwent valve reconstruction. The choice of xenograft valve was dictated by the condition of renal function. Patient survival and incidence of tricuspid regurgitation and freedom from operation for severe tricuspid regurgitation were analyzed with Kaplan-Meier method. RESULTS: The prevalence of tricuspid regurgitation was 20.1%. Mild and moderate tricuspid regurgitation was seen in 14.5 and 3.1% of the patients, respectively, who were responsive to medical therapy and remained clinically stable in NYHA class I-II. Severe tricuspid regurgitation was seen in 16 (2.5%) patients who presented signs of an acute right heart dysfunction. Tricuspid valve pathology at operation revealed biopsy-induced rupture of the Chordae tendineae at various valve segments mostly the anterior and posterior leaflets. There was one hospital death (<30 day) and five late deaths due to infection, arrhythmia and trauma and no procedural-related or directly cardiac related death. Ten patients (62.5%) are alive at a mean follow-up time of 29.9 months (range 4-81 months) and nine survivors are in NYHA class I-II and one in class III. CONCLUSIONS: Severe tricuspid regurgitation in transplanted hearts is associated mainly with biopsy-induced injury or endocarditis. Other regimes of rejection monitoring may help to eliminate this complication. Apart from our preference of valve repair, the choice of valve substitute may be influenced by the presence or the prospect of chronic renal failure. Heart transplant patients can safely undergo valve surgery with acceptable mortality, low morbidity and excellent intermediate-term clinical results. Mild to moderate functional tricuspid regurgitation is responsive to medical therapy and non-progressive and occur in 17.6% of orthotopic transplanted hearts without having a detrimental effect on the right ventricular performance.

Aged↗

Reproducibility of serial intravascular ultrasound measurements in patients with angiographically silent coronary artery disease after heart transplantation.

BACKGROUND: Intracoronary ultrasound (ICUS) imaging is the most sensitive method for the early detection and serial evaluation of vasculopathy of transplants. Both lack of agreement between observers and lack of agreement between serial, independent pullback procedures (repeatability), which can result in a variable intraluminal catheter position may limit the reproducibility of ICUS measurements. OBJECTIVE: To evaluate the reproducibility of serial measurements of standard linear and area cross-sectional coronary dimensions in patients with non-obstructive transplant vasculopathy. METHODS: We performed ICUS imaging of patients without angiographic evidence of obstructive epicardial coronary artery disease after heart transplantation. A 30 MHz phased-array transducer was used. Two independent pullbacks of the left anterior descending coronary artery were performed and recorded on CD-ROM for off-line quantitative analysis of the most severely diseased site. Agreement of observers and repeatability of serial measurements were calculated by the use of linear regression analysis and Bland-Altman plots. RESULTS: Regarding agreement of observers, correlation coefficients for intra-observer agreement ranged from r = 0.98 to r = 0.99; those for interobserver agreement ranged from r = 0.87 to r = 0.98. Serial measurements of the identical coronary artery cross-section within independent catheter pullback procedures were possible for 104 of 112 target lesions (92.90/%). Correlation coefficients ranged from r = 0.91 to r = 0.97 (for lumen diameter r = 0.91, for lumen area r = 0.93, for vessel diameter r = 0.91, for vessel area r = 0.97, for thickness of plaque r = 0.96 and for area of plaque 0.94). The mean difference of measurements was around zero for all parameters with SD from 0.13 to 0.4 mm for linear parameters and from 1.53 to 1.82 mm2 for area parameters. CONCLUSION: Serial intravascular ultrasound measurements are highly reproducible without any evidence of systematic error and a SD of differences of measurements beyond the maximal spatial resolution of currently available intravascular ultrasound catheters.

Coronary Angiography↗

Medium-term results of heart transplantation using donors over 63 years of age.

BACKGROUND: The continual shortage of hearts for transplantation (HTx) led to the expansion of the donor pool by accepting older donors. We compared the medium-term follow-up of patients after HTx with older hearts (over the age of 63 years) with those of patients after HTx with younger hearts. PATIENTS AND METHODS: Since April 1994 we have used hearts for HTx from donors older than the age of 63 years. Until November 1998, 309 HTx and 9 re-HTx were performed in 309 adults with a mean age of 50.7+/-10.9 years (range 17-68 years). There were 252 men and 57 women. The patients were divided into two groups: group I--donor age under 63 years (296 patients, mean age 50.4+/-11 years; mean donor age 38.1+/-13 years; mean follow-up 1.7+/-1.6 years); group II-donor age of more than 63 years (13 patients, mean age 57.4+/-5.6 years; mean donor age 65.1+/-2.1; mean follow-up 2.2+/-1.6 years). There were no differences in the etiology of heart failure, gender, or ischemia time between the groups. The patients in group II were significantly older (P = 0.008). Multiple factors were analyzed in the groups, which included changes in the left/right ventricle ejection fraction, early postoperative mortality (up to 30 days), cumulative survival rates and cardiac-dependent morbidity [myocardial infarction, malignant arrhythmias, coronary stenosis (>50% in one of the main coronary arteries) and transplant vasculopathy]. Additionally, freedom from cytomegalovirus infection (rise of titer or seroconversion) and freedom of acute rejection episodes grade > or =2 (International Society of Heart & Lung Transplantation [ISHLT]) were analyzed. RESULTS: After 1 year mean left and right ventricle ejection fraction were good in both groups and did not significantly change for up to 2 years. No Re-HTx was performed in group II. The early postoperative mortality was similar in both groups (P = 0.8). Also, the cumulative survival rates were similar in both groups (P = 0.87). Long-term cardiac morbidity was lower in group I (P = 0.03). The long-term freedom from cytomegalovirus infection in group I was significantly higher when compared with group II (P = 0.0002). The long-term freedom from severe rejection episodes was similar in both groups (P = 0.3) CONCLUSION: The study found a significant increase in long-term cardiac morbidity due to more focal coronary stenosis in group II, and freedom from cytomegalovirus infection, but did not find significant differences in the long-term survival between patients who received hearts from donors of up to 63 years of age and from those more than 63 years. The acceptance of donors older than 63 years old for HTx does not worsen the outcome of the recipients. The careful selection of older donors, with close monitoring of the coronary situation after HTx and expanded indications for revascularization of older hearts, could make HTx with older hearts, even in older recipients, a safe option.

Adolescent↗

Identification of P waves after the Cox-maze procedure: significance of right precordial leads V3R through V6R.

BACKGROUND: The maze circuit lengthens the period of atrial depolarization and may lead to small or absent P waves, which may not be readily apparent in a standard 12-lead electrocardiogram. In this prospective study, we investigate if the right precordial leads V3R through V6R can improve detection of P waves and identification of atrial electrical activity. METHODS: Standard 12-lead electrocardiograms (with leads I through III, aVR, aVL, aVF, and V1 through V6) and right precordial electrocardiograms (V3R through V6R) were recorded in 30 consecutive patients during the first 5 postoperative days and 1, 3, 6, 12, and 24 months after combined Cox-maze III procedure and mitral valve surgery. The P wave identification as an indication of atrial electrical activity and atrial contraction was proved by transesophageal echocardiographic identification of atrial contractions. RESULTS: Despite echocardiographically identifiable atrial contractions, the P waves were not visible on standard 12-lead electrocardiograms in 7 (23%) patients after 1 and 3 months, and in 4 patients after 6 months. In contrast, right precordial electrocardiograms showed P waves in all of these patients that were best seen in lead V4R. Twelve and 24 months postoperatively, only 2 patients had no visible P waves in the standard leads that were still present in the right precordial leads. However, if P waves were easily identifiable in standard 12-lead electrocardiograms (23 patients at 1 and 3 months after surgery), the right precordial leads showed P waves only in 15 patients. CONCLUSIONS: Right precordial electrocardiogram with leads V3R through V6R is a helpful tool for visualizing P waves after the Cox-maze procedure. Standard 12-lead electrocardiogram should be combined with right precordial electrocardiogram in all patients after the Cox-maze procedure.

Atrial Fibrillation↗

The Cox maze iii procedure: parallel normalization of sinus node dysfunction, improvement of atrial function, and recovery of the cardiac autonomic nervous system.

OBJECTIVE: The Cox maze III procedure includes isolation of the pulmonary veins and multiple incisions in both atria in what corresponds to partial autotransplantation and partial denervation of the heart. The aim of this prospective longitudinal study was to identify physiologic effects of reinnervation on changes in heart rate at rest and in response to various stimulations and on atrial function after the Cox maze III procedure. PATIENTS AND METHODS: Power spectral analysis of heart rate variability, exercise testing, 24-hour Holter monitoring, electrocardiography, and transthoracic and transesophageal echocardiography were performed in 30 adult patients after the combined Cox maze III procedure and mitral valve surgery (maze group). They were prospectively followed up at 1, 3, 6, and 12 months after the operation. The results were compared with those of 15 heart transplant recipients (transplant group) and normal probands (healthy adults, n = 12). RESULTS: The physiologic effects of denervation with no differences in cardiac autonomic activity between the groups were seen early after the operation. Later, evidence of autonomic reinnervation was observed only in the maze group but not in the transplant group. Inappropriate heart rate responses during physical exercise were clearly evident in both groups after 1 and 3 months, with progressive improvement seen between 6 and 12 months only in the maze group. Left atrial function after the Cox maze procedure improved parallel to the recovery of sinus node function. CONCLUSION: Progressive improvement of sinus node function and atrial contractions with significant functional normalization 1 year after the Cox maze procedure corresponded to functional reinnervation and recovery of the autonomic nervous system.

Adult↗

Coronary artery bypass grafting after orthotopic heart transplantation.

OBJECTIVE: Graft coronary disease (GCD) remains the major determinant of long-term survival after heart transplantation. Therapeutic strategies for the prevention or retardation of GCD in the cardiac allograft are limited, and palliative surgical coronary revascularization has been attempted. The aim of this report was to retrospectively analyze our results of coronary artery bypass grafting after cardiac transplantation. This paper correlates the outcome of patients with the pathohistological and angiographic type of lesion in order to identify transplant recipients who may profit from surgical myocardial revascularization. METHODS: Seven patients with a mean age of 55 years (range 45-61 years) underwent coronary artery bypass grafting as a result of GCD at a mean of 67 months (range 6-128 months) after cardiac transplantation. By the inclusion of the clinical history and the angiographic pattern of GCD lesions, the primary indications for surgical revascularization, operative results, pathohistological studies and follow-ups were examined. RESULTS: Elective surgery was performed in two patients with proximal, severe triple vessel disease (Type A lesion) and in one patient in whom the primary reason for cardiac surgery was severe tricuspid regurgitation. This patient electively received a tricuspid valve replacement and concomitant single vessel bypass surgery for proximal GCD (Type A lesion). Emergency surgery was performed in four patients: preoperatively three patients post-infarction developed worsening congestive heart failure, which resulted in low cardiac output syndrome. One patient with combined Types A and B/C lesions required emergency surgery for dissection of the right coronary artery (RCA) after an angioplasty procedure. Angiographically all these patients showed diffuse, distal arteriopathy (combined Type B/C lesions). The electively operated patients (n = 3) and the patient with dissection of the RCA (n = 1) had successful operations and survived beyond hospital discharge (overall survival for coronary artery bypass graft (CABG) in GCD patients 4 out of 7; 57%). All three patients with distal arteriopathy, who underwent emergency surgery, died in hospital from left ventricular failure (43%). The four patients discharged from hospital with a mean follow-up of 10 months (range 2-32 months) are all in good clinical condition. CONCLUSIONS: Coronary artery bypass grafting can be successfully performed in a subgroup of cardiac transplant patients with Type A lesions. However, the state of diffusely diseased distal arteries (Type B/C lesions), which is prevalent in this group of patients, limits the use of bypass surgery.

Biopsy↗

["Cox/Maze-III operation" as surgical therapy of chronic atrial fibrillation during mitral valve and atrial septal defect II operation].

PROBLEM: Atrial fibrillation is associated with significant morbidity and mortality. The increased risk of thromboembolism makes constant anti-coagulation necessary, while the absence of atrial contraction worsens the hemodynamic situation. In this study we examined the results of simultaneous surgical treatment of chronic atrial fibrillation through "Cox/Maze-III-procedure" while mitral valve surgery and atrial septal closure. PATIENTS AND METHODS: Between February 1995 and July 1997 sixteen patients aged 50 to 72 y (mean: 59 y) underwent open heart surgery (mitral valve replacement n = 10, reconstruction n = 3; mitral valve reconstruction and atrial septal closure n = 1, atrial septal closure n = 1, thrombectomy from left atrium n = 1) and "Cox/Maze-III-procedure" in one session. Preoperative duration of chronic atrial fibrillation was between 2 and 12 y (mean: 5.0 y). The patients were examined preoperatively and postoperatively 3, 6, 12, and 24 months after surgery using the following methods: transesophageal echocardiography (TEE), ECG, long-term ECG, and stress ergometry. RESULTS: During the early postoperative period (< 7 d) all of the patients were in sinus rhythm or atrial pacing; eight patients intermittently had atrial fibrillation. In the follow-up period from 1 to 27 months (mean 14 months), 15 patients have a stable sinus rhythm (94%). One patient, preoperatively known to have intermittent tachybradycardia, received a pacemaker 2 months postoperatively for sinus bradycardia. Postoperatively in TEE patients showed left atrial contraction with improvement of hemodynamic situation. Stress ergometry 6 months postoperatively showed lower increasements of heart rate, at 12 months normal frequency. CONCLUSION: The surgical treatment of chronic atrial fibrillation through "Cox/Maze-III-procedure" can be performed combined with other heart operations without increased perioperative or postoperative risks. The Maze-procedure is an effective surgical therapy of chronic atrial fibrillation. Postoperatively there is an improvement of the hemodynamic situation because of sinus rhythm and synchrone atrioventricular contraction.

Aged↗