PubMed Health⌕ Search

Biomedical subjects

M Nürnberg

Publications and source records attributed to M Nürnberg.

23 records · Page 2Linked to original sources

[Silent ischemia in long-term ECG in the early post-infarct period].

101 consecutive patients (73 m, 29 f; 48 AMI, 53 IMI) under 70 years were assigned to 24 hour-Holter monitoring in the third week after first transmural infarction. ST-segment analysis could be performed in 88 patients (89%). 18 patients (20%) had episodes of ischemia which were silent in 95%. One third of these episodes occurred in the absence of physical exercise. Ischemic events displayed a circadian rhythm with a maximum between 6 and 12 a.m. There was no correlation between ischemia and the occurrence of ventricular arrhythmia. In addition, we show that visual control of automatic ST-segment analysis is a prerequisite for routine use in clinical practice.

Aged↗

[Transvenous high frequency current ablation of atrioventricular conduction in therapy refractory tachycardic atrial fibrillation].

We present a case of radiofrequency ablation of the atrioventricular conduction system by means of intravenous catheter technique in a patient with drug-refractory paroxysmal atrial fibrillation. Total AV block was produced. Since the ablation and implantation of a pacemaker this female has had no recurrences. The advantages of this method compared with electrical fulguration are better control of delivered energy and reduction of complications (catheter perforation, thromboembolism). The disadvantage of radiofrequency ablation is the difficulty in positioning the catheter so as to give the most precise contact with the tissue, which is a very time-consuming procedure.

Aged↗

Problems of sensing tachyarrhythmias by an antitachycardia pacemaker (Symbios 7008).

Atrial burst pacing is an effective method of terminating supraventricular tachycardia. In the patient presented in this report, a Symbios 7008 pacemaker (Medtronic Inc., Minneapolis, MN, USA) was implanted for two reasons: (1) severe AV conduction defect (AH, 230 msec; HV, 150 msec) and bifascicular block following anterior myocardial infarction; and (2) paroxysmal atrial flutter. The conduction defect ruled out programming other than atrial burst in DDD mode. Activation of burst pacing required appropriate programming of the "tachycardia detection window" on the basis of the cycle length of the flutter waves. In the case reviewed, episodes of atrial flutter with variable cycle lengths of 230 to 280 msec necessitated reprogramming of the AV interval, the refractory period, and the upper rate interval. The use of an antitachycardia device in automatic mode may be limited by variations in tachycardia cycle length.

Aged↗