An improved correction of distorted indicator-dilution curves.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Nassi.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In order to assess the capability for measuring blood flow in small vessels, the cardiac output was measured directly by either the microsphere reference sample technique or by obtaining blood samples simultaneously with the CT scan. The cardiac output was also measured in vivo by dynamic CT scanning and intravenous contrast as the indicator in an indicator dilution curve. Cardiac output was then calculated by two convolution back projection algorithms which optimized for either contrast or spatial resolution. The results of this study suggest that CT scanners are capable of accurately averaging intravascular changes in contrast density. Although it is good to optimize contrast resolution, the convolution back projection algorithm selected must have a pixel matrix which is much smaller than the vessel being analyzed.
Variability of myocardial CT measurements, as indicated by standard deviations of mean CT numbers from four myocardial regions, was compared in 12-second scans, 3-second scans, and gated end-diastolic and end-systolic images, all from the same 12 seconds of scan data, both without and with radiographic contrast enhancement in experimental animals. There were statistically significant differences (P less than 0.05) in standard deviations of myocardial CT measurements when comparing 3-second and 12-second scans without contrast (10.4 vs. 7.7 CT#s), and 12-second scans without and with contrast (7.7 vs. 11.2 CT#s). Standard deviations of mean myocardial CT measurements were significantly greater (P less than 0.01) in gated images (end-diastolic) when compared with 12-second scans, both without contrast (22.2 vs. 7.7 CT#s) and with contrast (20.2 vs. 11.2 CT#s). In this study variability of myocardial CT measurements increased as scan time decreased, with radiographic contrast enhancement and with gating cardiac images.
Computed tomography (CT) provides a noninvasive technique with high resolution cross-sectional tomographic images which allow volume measurements of an object, independent of its geometric configuration. A phantom of known volume with controllable periodic motion was used to validate the CT method of volume determination. A good correlation (P less than 0.05) was achieved. Missing angle reconstruction algorithms for gating were applied to estimate left ventricular volumes and ejection fraction in an experimental animal, and the results compared with a standard angiographic method. Left ventricular volumes correlated poorly, whereas the ejection fraction obtained correlated well (r = 0.9). The discrepancies may be attributed in part to the CT method in which difficulties were recognized in defining the left ventricular borders at the base of the heart and partial volume effect, and in part to inaccuracies in the standard angiographic method. Once validated, this method has been applied to the animal model in the form of a pilot study.
Explore the source record for details and available documents.