PubMed Health⌕ Search

Biomedical subjects

M Oeff

Publications and source records attributed to M Oeff.

38 records · Page 3Linked to original sources

[Influence of digitalis on pindolol activity in exercise-induced cardiac failure in patients with coronary disease (author's transl)].

The activity of the beta-receptor blocker pindolol (0.4 mg i.v.) was investigated alone and in combination with digitalis (moderately fast loading) in 12 patients with coronary heart disease and without manifest signs of cardiac insufficiency. These patients showed pathological increase of left ventricular filling pressure during exercise testing. The exercise-induced rise of the mean pulmonary arterial and capillary pressures were increased by pindolol. Concurrently the increase of cardiac frequency was clearly diminished during ergometry (from 107/min without pindolol to 96/min, P less than 0.005). Digoxin given orally for an average of 5 days prevented the pressure increase in the pulmonary circulation induced by pindolol during exercise testing and at rest. The frequency reducing effect of pindolol was potentiated by digitalis. Use of digitalis alone did not influence mean exercise-induced pressure increase of the pulmonary circulation. In fact in some cases deterioration of these parameters was observed.

Acetyldigoxins↗

Localization of a ventricular tachycardia-focus with multichannel magnetocardiography and three-dimensional current density reconstruction.

The objective of this case report is to determine the accurate localization of a malignant ventricular tachycardia (VT) focus by combining multichannel magnetocardiographic (MCG) information with morphologic data. The localization was obtained by calculating the three-dimensional current density distribution (3D-CDD) on the left ventricular surface. To estimate the accuracy of this localization technique, examinations of a healthy volunteer were additionally performed. The MCG-signals were recorded in a magnetically shielded room by a 49-channel magnetogradiometer. The corresponding morphologic information was recorded by magnetic resonance tomography (MRT). The coordinate systems were matched with the help of markers. The 3D-CDD was calculated by the Philips CURRY software package. The origin of a malignant VT determined by X-ray images of the ablation catheter position during the electrophysiological examination (EPE), was used as the gold standard. This was then compared with the localization results obtained by the 3D-CDD. It was found that the localization coordinates showed a difference of less than 10 mm.

Adult↗