PubMed Health⌕ Search

Biomedical subjects

M Oizumi

Publications and source records attributed to M Oizumi.

3 recordsLinked to original sources

In vitro testing of a denture cleaning method using ozone.

The purpose of this study was to compare the microbicidal effect of gaseous ozone with that of ozonated water in order to determine its usefulness as a method for disinfecting dentures. Although a large number of research studies have been done on the bactericidal effect of ozone, little is known about its microbicidal effects on oral microorganisms. Therefore, we tested the effect of ozone on three standard strains of oral microorganisms: Streptococcus mutans (strain IID 973), Staphylococcus aureus (strain 209-P), and Candida albicans (strain LAM 14322). When the gaseous ozone injection method was used, the numbers of cells of all three strains decreased to 1/10(5) at 1 min, and by 3 min they were below the detection limit. Thus, the microbicidal effect of gaseous ozone was ascertained in a short time. In contrast, when ozonated water at 1 ppm and 3 ppm was used, C. albicans decreased to 1/10. A 700 mg/h ozone production level was needed to prepare 1 ppm ozonated water, whereas 20 mg/h of ozone was required by the gaseous ozone generator. These findings indicate that direct exposure to gaseous ozone seems to be a more effective microbicide compared with ozonated water, and that gaseous ozone can be clinically useful for disinfection of dentures.

Candida albicans↗

Influence of ozone on oxidation of dental alloys.

PURPOSE: The purpose of this study was to examine the influence of ozone on the surface of removable partial denture (RPD) alloys to determine its usefulness as a cleaning method for RPDs, since ozone has powerful sterilizing and deodorizing properties. MATERIALS AND METHODS: Two types of ozone cleaning were used. The quantities of ozone generated by both methods were the same (20 mg/h). In method A, ozone was generated for 10 minutes every 12 hours and in method B, ozone was generated over 24 hours a day. Test specimens of 3 types of dental alloy (Co-Cr, Au-Ag-Pt, and Au-Cu-Ag-Pd) were subjected to different cleaning methods for 7 days and measured in terms of reflectance, surface roughness, and weight. Five different cleaning solutions (three commercial denture cleaners, acid-electrolyzed water with a pH of 2.4, and pure water) were used for comparison with the ozone treatments. RESULTS: No significant changes were detected after treatment of the Co-Cr and Au-Ag-Pt alloys with ozone. Ozone caused a slight change in the Au-Cu-Ag-Pd alloy in terms of reflectance, but the changes were significantly less than those caused by acid-electrolyzed water and one of the commercial denture cleaners. CONCLUSION: Ozone had little influence on the oxidation of dental alloys.

Chromium Alloys↗

A preliminary report on continuous recording of salivary pH using telemetry in an edentulous patient.

PURPOSE: This study reports on the development and evaluation of a telemetry system for recording salivary pH. MATERIALS AND METHODS: The system used an iridium-oxide pH sensor (Metoxy sensor) and was housed inside a mandibular complete denture. It transmitted the data using the AM band (radio frequency of 12.3 MHz) and had a maximum power output of approximately 1 mW with a 3-V lithium battery (capacity 190 mAh). For the clinical evaluation, a 69-year-old woman who was edentulous and had no systemic disease was the subject. RESULTS: Under the conditions of the study, the system was able to operate for 19 hours. The maximum error of transmitted pH data values was pH 0.15 within the range from pH 5.0 to 9.0. The evaluation of the test subject showed that this system operated without problems, and that the pH levels responded appropriately. CONCLUSION: The developed system was shown to successfully record salivary pH, and it functioned as expected in a single test subject.

Aged↗