Neglectable benefit of searching for incidental findings in the Dutch-Belgian lung cancer screening trial (NELSON) using low-dose multidetector CT.

The purpose of this study was to prospectively determine the frequency and spectrum of incidental findings (IFs) and their clinical implications in a high risk population for lung cancer undergoing low-dose multidetector computed tomography (MDCT) screening for lung cancer. Scans of 1,929 participants were evaluated for lung lesions and IFs by two radiologists. IFs were categorised as not clinically relevant or possibly clinically relevant. Findings were considered possibly clinically relevant if they could require further evaluation or could have substantial clinical implications. All possibly clinically relevant IFs were reviewed by a third radiologist, who determined its clinical relevance. Of all 1,929 participants, 1,410 (73%) had not clinically relevant IFs and 163 (8%) had possibly clinically relevant IFs of which 129 (79%) were indeed considered clinically relevant. Additional imaging was performed mainly by ultrasound (112 of 118, 96%). All but one lesion were concluded to be benign, mostly cysts (n = 115, 80%). Only 21 (1%) participants had findings with clinical implications. In one participant a malignancy was found, yet without any clinical benefit since no curative treatment was possible. Based on our results, we advise against systematically searching for and reporting of IFs in lung cancer screening studies using low-dose MDCT.

Aged↗

Design and implementation of gradient vector flow snake to detect a reference object in pelvic x-rays for preoperative total hip arthroplasty planning application.

The main interest of this research project is to promote automation in performing preoperative planning for hip joint replacement surgery using a special medical image viewing software, ViewPro. Preoperative planning is performed to carefully prepare the surgery and to accurately select the hip implants. The first step of preoperative planning is to calibrate the x-ray image to adjust the magnification factor. A femoral head implant is used as magnification factor reference. Automation is introduced by developing an algorithm to automatically detect this reference object in the image. The algorithm used for performing the automatic detection of the reference object is gradient vector flow (GVF) snake. A study has been performed to compare the newly developed semiautomatic algorithm to the old manual calibration algorithm. The results show a close relation between the two algorithms (less than 1% of average relative difference). It is concluded that the developed semiautomated algorithm can be used as an alternative for performing the manual calibration.

Algorithms↗

MR spectroscopy and diffusion tensor imaging of the brain in congenital muscular dystrophy with merosin deficiency: metabolite level decreases, fractional anisotropy decreases, and apparent diffusion coefficient increases in the white matter.

Brain magnetic resonance spectroscopy (MRS) and diffusion tensor imaging (DTI) in one patient with merosin-deficient congenital muscular dystrophy (MDCMD) revealed significant metabolite (choline, creatine, N-acetyl aspartate) level reductions, fractional anisotropy (FA) reduction and increased apparent diffusion coefficient (ADC) in the white matter (p<0.01, all). In the gray matter, the MRS properties did not differ significantly from those in controls. The ADC and FA, however, differed significantly as in the white matter, although the differences were less pronounced. This is the first quantitative MR study of the brain in a patient with MDCMD, which revealed that the concentrations of all MRS measured metabolites were decreased only in the white matter. This observation, combined with the DTI observed ADC increases and FA decrease, indicated a presence of vasogenic edema in the white matter.

Anisotropy↗

The benefit of 64-MDCT prior to invasive coronary angiography in symptomatic post-CABG patients.

PURPOSE: The purpose of this study is to assess the diagnostic accuracy of 64-MDCT in symptomatic patients after CABG and to explore the advantages of the 64-MDCT results on the CAG procedure. MATERIAL AND METHODS: From December 2004 until August 2005, 34 post-CABG patients (29 men, mean age 63.5 +/- 8.5 years) with 69 coronary artery bypass grafts were scanned on a 64-MDCT (Somatom Sensation 64, Siemens AG, Forchheim, Germany) prior to CAG. Angiograms and 64-MDCT images were evaluated for the existence of occlusions or significant stenosis (>or=50% lumen reduction) in bypass grafts and native coronary arteries. RESULTS: 64-MDCT had a sensitivity, a specificity, and a diagnostic accuracy of 100% for occlusion detection. For stenosis detection, sensitivity was 100%, specificity 98.7% and diagnostic accuracy 98.7%. For detecting significant stenosis in native coronary arteries, 64-MDCT had a sensitivity of 80.0%, specificity of 90.8%, and a diagnostic accuracy of 87.1%. Seventeen patients (50.0%) did not need invasive treatment, 14 patients (41.2%) underwent a percutaneous coronary intervention (PCI), and 3 patients (8.8%) underwent surgery. Treatment advice based on 64-MDCT was correct in 88.2% of patients and when 64-MDCT results would have been known 58.8% of diagnostic CAG procedures could have been prevented. CONCLUSION: In conclusion, 64-MDCT has a high diagnostic accuracy in detecting bypass graft stenosis and occlusions, and 64-MDCT based treatment advice was correct in 88.2% of patients.

Aged↗

The clinical value of a negative multi-detector computed tomographic angiography in patients suspected of coronary artery disease: A meta-analysis.

The aim of this meta-analysis was to calculate the sensitivity of contrast-enhanced multi-detector computed tomography (MDCT) compared with coronary angiography (CAG) in incident patients suspected of coronary artery disease (CAD). We searched PubMed, Embase, bibliographies of original papers and reviews to identify original papers including > or =20 patients. Two independent reviewers selected papers and judged eligible papers on quality. Heterogeneity was assessed and homogeneous subgroups were pooled. Of the 15 included studies, ten provided moderately homogeneous patient-based analyses with absolute diagnostic numbers (n = 630 patients). Pooled sensitivity was 89% (95% confidence interval: 85-92%). Scanners with 16 detectors (n = 4) had higher sensitivities (pooled sensitivity: 91%) than four-detector scanners (n = 6; pooling not possible due to heterogeneity). Seven studies reported sensitivity for a proximal stenosis, but different definitions were used making pooling impossible; sensitivities ranged from 75 to 100%. The sensitivity of four- and 16-detector MDCT is not sufficient to rule out any stenosis in patients suspected of CAD. No conclusions can be drawn with respect to the sensitivity for clinically relevant or proximal stenoses.

Contrast Media↗

A model for temporal resolution of multidetector computed tomography of coronary arteries in relation to rotation time, heart rate and reconstruction algorithm.

A model is presented that describes the image quality of coronary arteries with multidetector computer tomography. The results are discussed in the context of rotation time of the scanner, heart rate, and number of sectors used in the acquisition process. The blurring of the coronary arteries was calculated for heart rates between 50 and 100 bpm for rotation times of 420, 370, and 330 ms, and one-, two-, three-, and four-sector acquisition modes and irregular coronary artery movement is included. The model predicts optimal timing within the RR cycle of 45+/-3% (RCA), 44+/-4% and 74+/-6% (LCX), and 35+/-4% and 76+/-5% (LAD). The optimal timing shows a negative linear dependency on heart rate and increases with the number of sectors used. The RCA blurring decreases from 0.98 cm for 420 ms, one-sector mode to 0.27 cm for 330 ms, four-sector mode. The corresponding values are 0.81 cm and 0.29 cm for LCX and 0.42 cm and 0.17 cm for LAD. The number of sectors used in a multisector reconstruction and the timing within the cardiac cycle should be adjusted to the specific coronary artery that has to be imaged. Irregular coronary artery movement of 1.5 mm justifies the statement that no more than two sectors should be used in multisector acquisition processes in order to improve temporal resolution in cardiac MDCT.

Algorithms↗

MR spectroscopy of brain white matter in the prediction of dementia.

BACKGROUND: Previous 1H-MR spectroscopy (MRS) studies compared biochemical spectra of persons with dementia with those of healthy control subjects. Given the long prodromal period of Alzheimer disease (AD), the authors sought to investigate whether biochemical changes can be observed also in the preclinical period. METHODS: The authors prospectively followed 509 elderly persons (ages 60 to 90), who were free of clinical dementia at baseline, for on average 5.9 years. At baseline, 1H-MRS of the brain (1.5 T) was performed in a plane above the lateral ventricles that comprised mainly white matter voxels. Standard ratios of N-acetyl aspartate (NAA), choline (Cho), and creatine (Cr) were calculated. Structural MRI was administered to assess white matter lesions and hippocampal atrophy. All persons were followed for incident dementia through repeated neuropsychological testing and linkage with medical records. RESULTS: During follow-up, 37 persons developed dementia, of whom 27 fulfilled criteria for AD. Overall, biochemical ratios on 1H-MRS at baseline were not associated with the risk of incident dementia. However, people with higher Cho/Cr ratios had a higher risk to develop dementia or AD within 4 years (hazard ratio for dementia per SD increase 1.55 [95% CI 1.05 to 2.28]). This association attenuated and became nonsignificant after adjustment for white matter lesions on MRI. CONCLUSION: These data suggest that there are biochemical changes on 1H-MR spectroscopy of brains of persons with presymptomatic dementia.

Aged↗

Evaluation of the use of CD-ROM upload into the PACS or institutional web server.

PURPOSE: Patient data are increasingly distributed between hospitals using CD-ROMs instead of actual films. This introduces problems because different viewers from different vendors are provided, and sometimes viewers are unusable because local software installation is not allowed. In 2004, we started to facilitate the incorporation of CD-ROM data into the normal workflow of the hospital by using commercially available software to perform patient reconciliation based on the DICOM (digital imaging and communication in medicine) modality worklist. The purpose of the current study is to evaluate this new procedure. METHODS AND MATERIALS: A questionnaire was sent to all users to evaluate the satisfaction with the current facility and to evaluate possible improvements. Several quality parameters on speed and satisfaction were rated on a 5-point scale (1 = bad to 5 = excellent). RESULTS: Replies from 17 different respondents were evaluated, accounting for an average of 76 CD-ROMs per week. Mean (median) results showed a score of 3.6 (4) for handling time, 3.4 (4) for archival of second opinion data, 3.8 (median 4) for archival of external data onto the web server, and 4.5 (median 5) for the overall performance of the current procedure. CONCLUSION: Although some improvements can be made, storage of the study data from CDs from outpatients into PACS (picture archiving and communication system) and web server already provides for an existing need. Using this service, physicians can access the data with ease and familiarity. User satisfaction with the provided solution is high.

CD-ROM↗

Diffusion tensor imaging and magnetic resonance spectroscopy of the brain in a patient with Sturge-Weber syndrome.

Quantitative brain MR spectroscopy (MRS) and diffusion tensor imaging (DTI) were used to characterize one patient with Sturge-Weber syndrome. Choline increases and N-acetylaspartate decreases were observed in pathologic frontal gray matter tissue compared to contralateral unaffected brain tissue without any change in the diffusion tensor imaging parameters (fractional anisotropy, apparent diffusion coefficient). The N-acetylaspartate decreases and/or choline increases observed here and in eight previously described Sturge-Weber patients probably reflect neuronal loss or dysfunction and demyelination as a result of recurrent seizures.

Brain↗

Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature.

Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.

Humans↗

Time-of-flight magnetic resonance angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils.

The purpose of this study was to evaluate time-of-flight magnetic resonance angiography (MRA) in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDCs). From January 1998 to January 2002 27 MRA and intra-arterial digital subtraction angiography (IADSA) examinations were analyzed for residual aneurysms and arterial patency following GDC placement. A total number of 33 intracranial aneurysms was analyzed, including 18 located in the posterior circulation. The MRA analysis was based on source images in combination with maximum intensity projections. The IADSA was used as the reference standard. Two aneurysms were excluded from evaluation, because of susceptibility artefacts from other aneurysms, which were clipped. Sensitivity and positive predictive values of MRA in revealing residual aneurysms were, respectively, 89% and 80%. Specificity in ruling out remnant necks and residual flow around coils was, respectively, 91% and 97%, with a negative predictive value of, respectively, 95% and 100%. Specificity and negative predictive value of MRA for arterial occlusion were, respectively, 87% and 100% for the parent arteries and, respectively, 85% and 100% for the adjacent arteries. MRA is a reliable diagnostic tool in the follow-up of GDC treatment, and it may replace IADSA in excluding residual flow around coils and aneurysmal necks and in ruling out arterial occlusion.

Adult↗

A 16-slice multidetector computed tomography protocol for evaluation of the gastroepiploic artery grafts in patients after coronary artery bypass surgery.

Arterial coronary bypass grafts [internal mammary arteries and gastroepiploic artery (GEA)] are in widespread use for coronary surgery. Since selective catheterisation of the GEA graft to monitor patency, is often unsuccessful, a non-invasive protocol to visualise the GEA-graft from origin to anastomosis is presented using 16-slice multidetector computed tomography (MDCT). Twenty-six male patients (mean age 58.1+/-6.7 years) with GEA grafts were scanned according to a protocol of an ECG-synchronised cardiac scan followed by a thoracoabdominal scan. To terminate the scan at the correct anatomical level, the lowest level of the GEA was coded based on the lumbar vertebrae level. Scores ranging from one (excellent) to four (bad) were assigned to evaluate visualisation quality of the grafts. GEA grafts were assessable in 62% of the thoracoabdominal scans and 69% of the cardiac scans. On average, the lowest part of the GEA corresponded with a level between L1 and L2, in two cases in the upper part of L3. Mean visualisation score in the thoracoabdominal scans and cardiac scans was good (respectively 1.4+/-0.6 and 1.4+/-1.0). Sixteen-slice MDCT is a promising alternative for catheterisation in evaluating patency of GEA grafts, using the presented protocol with thoracoabdominal scan including L3 for complete coverage of the GEA graft.

Clinical Protocols↗

1H chemical shift imaging of the brain in guanidino methyltransferase deficiency, a creatine deficiency syndrome; guanidinoacetate accumulation in the gray matter.

MR spectroscopy results in a mild case of guanidinoacetate methyltransferase (GAMT) deficiency are presented. The approach differs from previous MRS studies in the acquisition of a chemical shift imaging spectral map showing gray and white matter with the corresponding spectra in one overview. MR spectroscopy revealed guanidinoacetate (GAA) in the absence of creatine. New is that GAA signals are more prominent in gray matter than in white. In the prevailing view, that enzyme deficiency is localized in liver and pancreas and that all GAA is transported into the brain from the blood and the cerebrospinal fluid, this would be compatible with a more limited uptake and/or better clearance of GAA from the white matter compared to the grey matter.

Aspartic Acid↗

Incorporating out-patient data from CD-R into the local PACS using DICOM worklist features.

With the introduction of digital imaging in radiology, CD-Rs are increasingly used to distribute patient materials. This study investigates the application of a new software package and work protocol to integrate out-hospital data into the local PACS (picture archive and communication system) archive, which is hampered by differences in patient numbers. A one-month trial was started to import CD-Rs from two departments (radiotherapy and radiology). Seventy CD-Rs were collected from 20 different hospitals holding data of eight different modality types and published by eight different software packages from different vendors. All CD-Rs were successfully transferred into the PACS. The new software and work protocol provide an easy way of introducing the out-hospital data into the PACS. CD-Rs can be destroyed after transfer to PACS, eliminating physical storage. Furthermore, all data can now be viewed and reported using the default viewers of the hospital and no additional training of staff is required.

CD-ROM↗

Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography.

This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic modality were compared to the findings of traditional coronary angiography. In the first patient MDCT showed occlusion of the left internal mammary artery (LIMA) and saphenous vein graft after the second anastomosis. Coronary angiography confirmed these findings. In the second patient EBT showed patency of the LIMA and saphenous vein graft. After the first anastomosis of the saphenous vein graft, the connected vessel filled poorly. Coronary angiography confirmed both grafts to be patent, and detected an occlusion distal to the first anastomosis. These findings support the evidence that both MDCT and EBT are suitable techniques for establishing bypass graft patency by non-invasive means.

Angina Pectoris↗