PubMed Health⌕ Search

Biomedical subjects

M P Andre

Publications and source records attributed to M P Andre.

7 recordsLinked to original sources

Integral role of interventional radiology in the development of a pediatric liver transplantation program.

The aim of this study was to examine the role of interventional radiology (IR) in the pretransplant evaluation of potential living-related liver transplantation (LRLT) donors and in the post-transplant management of pediatric liver transplant recipients. Medical records and procedural reports were reviewed of 12 potential donors and five recipients for left lateral segment liver transplants. Procedures performed by the IR Division, clinical indications, and complications were tabulated. Retrospective calculation of radiation exposure to the skin and gonads of the donors and recipients were made. Three-dimensional ultrasound (3D US) was used in all 12 potential donors to screen for the donor with the most appropriately sized left lateral segment. The four optimal donor candidates underwent contrast angiography in order to measure the diameter and screen for variant arterial supply to the left lateral segment. Pretransplantation, one recipient underwent mesenteric angiography with indirect portography to confirm thrombosis of the portal vein and to prove patency of the splenomesenteric venous confluence. Three children underwent LRLT and two children received split livers from cadaveric donors. Thirty-two IR procedures were performed after transplantation (Tx) in the four transplant survivors (one child died following Tx). These IR procedures included: ultrasound-guided percutaneous liver biopsy to evaluate the pathologic cause of liver dysfunction (seven); placement of nasal jejunal feeding tubes (three) or a peripherally inserted central catheter (four) for nutritional and pharmacologic support; large-volume diagnostic and therapeutic paracentesis (two) and thoracentesis (one); percutaneous catheter drainage of symptomatic large pleural effusions (two), large-volume chylous ascites (one) (with later drain removal [one]), and a large biloma (one); percutaneous biliary drain placement (three), biliary drain replacement (two), and balloon cholangioplasty (four) to relieve obstructive jaundice from biliary enteric anatomic strictures; and mesenteric arteriography (one) for suspected thrombosis of the hepatic artery. No complications occurred. Mean skin and gonadal radiation doses were 193 mGy and 27 mGy, respectively, for donors, and 164 mGy and 60 mGy, respectively, for recipients. Even in a program such as this, with a limited series of pediatric liver Txs, it is apparent that IR plays an integral role in optimizing the clinical outcome and use of resources. Specific benefits included: selection of optimal donors; accurate mapping of the donor and occasionally recipient hepatic vasculature; and, most importantly, providing relatively safe minimally invasive procedures for nutritional support and diagnosis and management of untoward events after Tx. When possible, ultrasound guidance should be used to avoid excessive cumulative fluoroscopic exposure to recipients.

Adolescent↗

Quantitative computed tomography in the evaluation of spinal osteoporosis following spinal cord injury.

Disuse osteoporosis occurs in the lower extremities of patients with spinal cord injury (SCI). However, spinal osteoporosis is not usually observed in these patients. We investigated lumbar spine bone mineral density (BMD) in SCI patients using single energy quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA). Our study population consisted of 64 patients with long-standing SCI. Spine BMD (g/cm3) was assessed by QCT at four vertebrae ranging from T11 to L4 with single mid-vertebral CT slices 1 cm thick parallel to the vertebral end-plates. Confounding variables affecting normal trabecular bone pattern, such as compression fractures, surgical hardware or fat replacement, were excluded. For a subset of 29 patients, DXA values of the spine and femoral neck were also measured, and QCT and DXA Z-scores were compared On the average, the 64 SCI patients had Z-scores 2.0 +/- 1.2 below those of age-matched controls. In the subset of 29 patients with both QCT and DXA measurements, the QCT and DXA Z-scores were 2.4 +/- 1.1 below and 1.3 +/- 2.3 above the mean, respectively (p < 0.0001). Our results indicate that QCT reveals osteoporosis of the spine after SCI, in contrast to DXA. We postulate that QCT is more valuable for evaluating spinal osteoporosis following SCI than DXA and thus recommend QCT for spinal BMD studies in SCI.

Absorptiometry, Photon↗

Rotator cuff disruption: diagnosis with digital arthrography.

Shoulder arthrography is a reliable technique for use in the diagnosis of tears of the rotator cuff, although delineation of the precise site and size of tears requires meticulous double-contrast technique and considerable examiner expertise. The authors initiated a prospective evaluation of digital arthrography of the glenohumeral joint in 28 patients with clinical manifestations suggesting rotator cuff tear because they believed that examination with this technique would allow more accurate definition of the precise status of the cuff. Fifteen patients had normal studies. Ten complete and three partial rotator cuff tears were demonstrated with digital technique, and the precise site of the tear was demonstrated in all of these cases. The results indicate that digital arthrography of the glenohumeral joint may have some advantages over standard arthrography in the delineation of complete and partial tears of the rotator cuff, particularly in defining the exact site of tears.

Adult↗

Ultrasonic enhancement of myocardial infarction with perfluorocarbon compounds in dogs.

Fluosol-DA 20% (Fluosol) and perfluoroctylbromide (PFOB), 2 types of perfluorocarbon emulsions (PFCs), were evaluated as sound contrast agents in imaging acute myocardial infarction (MI) in dogs. Operative ligation of a coronary artery was performed in 9 dogs. PFC was administered 2 days after occlusion. One dog received Fluosol, 10 ml/kg body weight, 2 dogs received 20 ml/kg, and 2 received 25 ml/kg; 2 dogs received PFOB, 20 ml/kg, and 2 dogs received 25 ml/kg. Just before and 2 days after PFC administration, real-time, 2-dimensional ultrasound examination of the heart was performed in the short-axis view from apex to base. No enhancement was seen at the 10-ml/kg dose, but significant mild echogenic enhancement of all MIs occurred after 20 ml/kg. Moderate to marked enhancement was noted after 25 ml/kg. The enhancement was either diffuse throughout the MI or localized to the rim. Initial studies suggest that the mechanism of enhancement is related, at least in part, to the accumulation of PFC-filled macrophages within the MI.

Animals↗

Effects of transient coronary ischemia and reperfusion on myocardial edema formation and in vitro magnetic relaxation times.

The effects of transient ischemia and reperfusion on regional myocardial function, salvage and swelling have been systematically analyzed in experimental canine preparations. The results of these interventions on myocardial in vitro measurements of magnetic relaxation times (T1 = magnetization recovery, T2 = spin echo) are of significant importance with respect to future nuclear magnetic resonance tomographic imaging. Thus, using a pulsed magnetic resonance spectrometer (10.7 MHz), myocardial tissue samples from two groups of dogs were evaluated. In group 1 (n = six dogs), the left anterior descending artery was occluded for 3 hours before sacrifice; in group 2 (six dogs), 3 hours of occlusion was followed by 1 hour of reperfusion. Multiple tissue samples from normal and ischemic (or ischemic and reperfused) myocardium were obtained for measurement of T1, T2 and % water content (wet weight--dry weight/wet weight). Water content increased with ischemia (78 +/- 4%) and reperfusion (81 +/- 4%) (both p less than 0.01 versus control values). Values for T1 increased with ischemia (598 +/- 39 versus 487 +/- 23 ms in normal tissue from the same heart, p less than 0.01). Even greater T1 changes occurred in the animals with reperfusion (654 +/- 52 ms, p less than 0.01 versus the intra-animal control values). Changes in T2 were similar but less marked (ischemic zone 43.9 +/- 1.0 versus 41.2 +/- 1.0 ms in nonischemic tissue in the corresponding heart, p less than 0.05; reperfusion zone 48.3 +/- 3.5 versus 41.9 +/- 2.3 ms in the normal zone, p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

In vitro magnetic relaxation times of the ischemic and reperfused rabbit kidney: concise communication.

To assess the effects of renal ischemia and reperfusion on in vitro magnetic relaxation times (T1 = magnetization recovery, T2 = spin echo), we evaluated the spectroscopic characteristics of the renal cortex from 25 rabbits. Eight served as controls (Group 1), nine had one renal pedicle ligated for 1 hr (Group 2), and eight (Group 3) were occluded for 1 hr and reperfused for 30 min. For intra-animal comparison purposes, % H2O content, T1 (msec), and T2 (msec) of the ischemic (reperfused) kidney were normalized to the values from the normal kidney within the same animal. Renal ischemia consistently increased water content, which was exaggerated by reperfusion. In association with ischemia, T1 fell, and with reperfusion T1 lengthened. T2 increased with ischemia and declined from the peak ischemic effects with reperfusion.

Animals↗