PubMed Health⌕ Search

Biomedical subjects

M P Braeuning

Publications and source records attributed to M P Braeuning.

17 recordsLinked to original sources

Informing patients of diagnostic mammography results: mammographer's opinions.

PURPOSE: The authors' purpose was to determine mammographers' practices and attitudes regarding disclosing results of diagnostic mammograms to patients. MATERIALS AND METHODS: In 1995, the authors mailed a questionnaire to 500 members of the Society of Breast Imaging; 399 (80%) responded to the survey. RESULTS: Three-quarters of respondents stated that mammographers should disclose results to their patients, and approximately half were already doing so (52% for normal results, 51% for abnormal results). A sizable minority (25%) said that not telling patients was the best practice and identified several barriers to direct disclosure, including lack of time. Although bivariate analysis showed direct disclosure to be more common among female mammographers, the sex difference did not persist in multivariate analysis. In both bivariate and multivariate analyses, reading more than 100 mammograms per week and having a radiology practice in a university or academic setting were each strongly associated with direct disclosure. CONCLUSION: Implementation of the Mammography Quality Standards Reauthorization Act of 1998 may not require a major change in mammographers' current practice. It remains critical to establish systems that help radiologists disclose results and communicate with referring physicians efficiently and effectively.

Adult↗

Communicating results of diagnostic mammography: what do patients think?

RATIONALE AND OBJECTIVES: The purpose of this study was to investigate women's preferences for who (radiologist or referring physician) should communicate the results of diagnostic mammography. MATERIALS AND METHODS: Data from 153 women presenting to two sites for diagnostic mammography between February and June 1995 were collected with a 24-item, self-administered, closed-ended survey. For both normal and abnormal hypothetical results, contingency tables with chi2 tests and multiple logistic regression were used to determine the association, if any, between women's characteristics and their preferences. RESULTS: Women undergoing diagnostic mammography preferred that their radiologists disclose their normal (90%) and abnormal (88%) mammogram results to them immediately after their examination, rather than have their referring physicians disclose results at a later time. In the case of normal findings, women whose regular physicians were specialists were less likely to want to hear first from their radiologists (odds ratio [OR] = 0.06; 95% confidence interval [CI] = 0.01, 0.77; P = .03), but women who were nervous about learning their results were more likely to want to hear first from their radiologists (OR = 4.5; 95% CI = 1.2, 17.3; P = .03). CONCLUSION: Radiologists may want to consider assessing women's preferences for who communicates their mammogram results, as most women in this study preferred to hear these results from their radiologists rather than waiting to hear from their referring physicians.

Female↗

Has the mammography quality standards act affected the mammography quality in North Carolina?

OBJECTIVE: The United States Food and Drug Administration implemented federal regulations governing mammography under the Mammography Quality Standards Act (MQSA) of 1992. During 1995, its first year in implementation, we examined the impact of the MQSA on the quality of mammography in North Carolina. MATERIALS AND METHODS: All mammography facilities were inspected during 1993-1994, and again in 1995. Both inspections evaluated mean glandular radiation dose, phantom image evaluation, darkroom fog, and developer temperature. Two mammography health specialists employed by the North Carolina Division of Radiation Protection performed all inspections and collected and codified data. RESULTS: The percentage of facilities that met quality standards increased from the first inspection to the second inspection. Phantom scores passing rate was 31.6% versus 78.2%; darkroom fog passing rate was 74.3% versus 88.5%; and temperature difference passing rate was 62.4% versus 86.9%. CONCLUSION: In 1995, the first year that the MQSA was in effect, there was a significant improvement in the quality of mammography in North Carolina. This improvement probably resulted from facilities' compliance with federal regulations.

Mammography↗

Effects of processing conditions on mammographic image quality.

RATIONALE AND OBJECTIVES: Any given mammographic film will exhibit changes in sensitometric response and image resolution as processing variables are altered. Developer type, immersion time, and temperature have been shown to affect the contrast of the mammographic image and thus lesion visibility. The authors evaluated the effect of altering processing variables, including film type, developer type, and immersion time, on the visibility of masses, fibrils, and speaks in a standard mammographic phantom. MATERIALS AND METHODS: Images of a phantom obtained with two screen types (Kodak Min-R and Fuji) and five film types (Kodak Min-R M, Min-R E, Min-R H; Fuji UM-MA HC, and DuPont Microvision-C) were processed with five different developer chemicals (Autex SE, DuPont HSD, Kodak RP, Picker 3-7-90, and White Mountain) at four different immersion times (24, 30, 36, and 46 seconds). Processor chemical activity was monitored with sensitometric strips, and developer temperatures were continuously measured. The film images were reviewed by two board-certified radiologists and two physicists with expertise in mammography quality control and were scored based on the visibility of calcifications, masses, and fibrils. RESULTS: Although the differences in the absolute scores were not large, the Kodak Min-R M and Fuji films exhibited the highest scores, and images developed in White Mountain and Autex chemicals exhibited the highest scores. CONCLUSION: For any film, several processing chemicals may be used to produce images of similar quality. Extended processing may no longer be necessary.

Absorptiometry, Photon↗

Contrast limited adaptive histogram equalization image processing to improve the detection of simulated spiculations in dense mammograms.

The purpose of this project was to determine whether Contrast Limited Adaptive Histogram Equalization (CLAHE) improves detection of simulated spiculations in dense mammograms. Lines simulating the appearance of spiculations, a common marker of malignancy when visualized with masses, were embedded in dense mammograms digitized at 50 micron pixels, 12 bits deep. Film images with no CLAHE applied were compared to film images with nine different combinations of clip levels and region sizes applied. A simulated spiculation was embedded in a background of dense breast tissue, with the orientation of the spiculation varied. The key variables involved in each trial included the orientation of the spiculation, contrast level of the spiculation and the CLAHE settings applied to the image. Combining the 10 CLAHE conditions, 4 contrast levels and 4 orientations gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 40 backgrounds. Twenty student observers were asked to detect the orientation of the spiculation in the image. There was a statistically significant improvement in detection performance for spiculations with CLAHE over unenhanced images when the region size was set at 32 with a clip level of 2, and when the region size was set at 32 with a clip level of 4. The selected CLAHE settings should be tested in the clinic with digital mammograms to determine whether detection of spiculations associated with masses detected at mammography can be improved.

Female↗

The politics of breast imaging.

There are numerous political issues concerned with the roles of breast imaging in the detection, diagnosis, and management of breast cancer. These include issues regarding screening mammography, quality control, and results including cost-effectiveness of medical-legal considerations, but also their relation to overall health care of other societal needs.

Journal Article↗

Does intensity windowing improve the detection of simulated calcifications in dense mammograms?

This study attempts to determine whether intensity windowing (IW) improves detection of simulated calcifications in dense mammograms. Clusters of five simulated calcifications were embedded in dense mammograms digitized at 50-microns pixels, 12 bits deep. Film images with no windowing applied were compared with film images with nine different window widths and levels applied. A simulated cluster was embedded in a realistic background of dense breast tissue, with the position of the cluster varied. The key variables involved in each trial included the position of the cluster, contrast level of the cluster, and the IW settings applied to the image. Combining the ten IW conditions, four contrast levels and four quadrant positions gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 160 backgrounds. The entire experiment consisted of 800 trials. Twenty student observers were asked to detect the quadrant of the image in which the mass was located. There was a statistically significant improvement in detection performance for clusters of calcifications when the window width was set at 1024 with a level of 3328, and when the window width was set at 1024 with a level of 3456. The selected IW settings should be tested in the clinic with digital mammograms to determine whether calcification detection performance can be improved.

Breast Neoplasms↗

The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting.

The purpose of this study was to determine whether intensity windowing (IW) improves detection of simulated masses in dense mammograms. Simulated masses were embedded in dense mammograms digitized at 50 microns/pixel, 12 bits deep. Images were printed with no windowing applied and with nine window width and level combinations applied. A simulated mass was embedded in a realistic background of dense breast tissue, with the position of the mass (against the background) varied. The key variables involved in each trial included the position of the mass, the contrast levels and the IW setting applied to the image. Combining the 10 image processing conditions, 4 contrast levels, and 4 quadrant positions gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 160 backgrounds. The entire experiment consisted of 800 trials. Twenty observers were asked to detect the quadrant of the image into which the mass was located. There was a statistically significant improvement in detection performance for masses when the window width was set at 1024 with a level of 3328. IW should be tested in the clinic to determine whether mass detection performance in real mammograms is improved.

Analysis of Variance↗

New modalities in breast imaging: digital mammography and magnetic resonance imaging.

Mammography is currently the only screening method available with proven capability to diagnose nonpalpable breast cancer. However, mammography does not detect all cancers. Cancers are more difficult to detect in radiographically dense breasts because lesions are obscured by breast tissue. Digital mammography and magnetic resonance imaging of the breast may minimize the problems associated with screening dense breasts. If these methods prove to be useful, more cancers could be detected at an earlier stage.

Breast↗

Interpretation time of serial chest CT examinations with stacked-metaphor workstation versus film alternator.

PURPOSE: Interpretation time of serial staging chest CT cases, which each contained current and previous examinations, with a simple prototype workstation called filmstack was experimentally compared with interpretation time with a film alternator. MATERIALS AND METHODS: The filmstack displayed a "stack" of sections for each examination; user controls allowed rapid selection of preset attenuation windows and both synchronized and unsynchronized scrolling. Eight radiologists were timed as they used the filmstack and the film alternator to interpret four ergonomically complex serial CT cases. RESULTS: All reports dictated on the basis of findings with filmstack and film were of acceptable clinical accuracy. The time to examine a case with filmstack was significantly faster than the time with film, including the time to load and unload the alternator (99% confidence [P = .01]). There was no statistically significant difference in interpretation time between filmstack and prehung film. CONCLUSION: Use of a low-cost stacked CT workstation with a single 1,024 x 1,024 monitor is an effective means of interpreting cases that require comparison of multiple CT examinations.

Computer Systems↗

Paget disease of the breast: a pictorial essay.

Paget disease of the breast accounts for approximately 2%-3% of breast cancers. It is characterized by infiltration of the nipple epidermis by adenocarcinoma cells, which cause an eczematous eruption on the nipple and areola. The clinical features are highly suggestive of the disease; awareness of these on the part of the clinician should lead to more prompt diagnosis and earlier initiation of appropriate treatment. Mammograms, although not always positive, should be obtained in all cases suggestive of Paget disease to search for the underlying tumor and direct further treatment. Findings that may be seen at mammography include skin thickening, nipple retraction, subareolar or more diffuse malignant microcalcifications, and a discrete mass or masses. However, a negative mammogram should not alter the course of treatment. Conversely, identification of subareolar mammographic findings should alert the clinician to search for physical signs in the nipple and areolar region suggestive of Paget disease.

Breast Neoplasms↗