PubMed Health⌕ Search

Biomedical subjects

M P García de Llasera

Publications and source records attributed to M P García de Llasera.

2 recordsLinked to original sources

Matrix solid-phase dispersion extraction and determination by high-performance liquid chromatography with fluorescence detection of residues of glyphosate and aminomethylphosphonic acid in tomato fruit.

A method based on matrix solid-phase dispersion (MSPD) is described for the quantitative extraction of glyphosate and its major metabolite aminomethylphosphonic acid (AMPA) from tomato fruit. After application of 120 microL of HNO3 1M to the sample, the dispersion column was packed with 0.5 g of sample blended into 1 g of NH2-silica. Two aqueous fractions were obtained. First, AMPA was eluted from the column using deionized water (F1), and then a NaH2PO4 0.005 M solution was used for the elution of glyphosate (F2). Cleanup of F1 and F2 was made by ion exchange chromatography on a SAX anion exchange silica. Determination was done by HPLC with fluorescence detection after precolumn derivatization with 9-fluorenylmethylchloroformate (FMOC-Cl). Mean recoveries calculated at fortification levels of 0.5 microg/g for glyphosate and 0.4 microg/g for AMPA were 87% and 78%, respectively. The relative standard deviations (n=7) for the total procedure were 10% and 16%. Detection limits were 0.05 microg/g for glyphosate and 0.03 microg/g for AMPA.

Chromatography, High Pressure Liquid↗

Presence of carbamate pesticides in environmental waters from the northwest of Mexico: determination by liquid chromatography.

A study on the presence of carbamate pesticides, namely aldicarb, aldicarb sulfoxide, baygon, benthiocarb, carbofuran, 3-hydroxycarbofuran, carbaryl, desmedipham, methiocarb, methomyl, thiodicarb, oxamyl, and propham was made in ground and surface waters from an agricultural zone of the Yaqui Valley located in northwest Mexico. Trace determinations were made by liquid chromatography (LC) with post-column fluorescence detection (EPA method 531.1) or LC-diode array UV detection coupled on-line to a solid-phase extraction (SPE) system and using a 13 x 4.6 mm i.d. precolumn and a 150 x 4.6 mm i.d. analytical column, both packed with a C18 silica. Results indicated that the level of contamination with methiocarb was 5.4 micrograms/L in a groundwater sample and that for 3-hydroxycarbofuran was 18 micrograms/L in a surface water sample. This study provides the basis for a future monitoring program.

Agriculture↗