PubMed HealthSearch

Biomedical subjects

M P Saccomani

Publications and source records attributed to M P Saccomani.

5 recordsLinked to original sources

Domain of validity of classical models of leucine metabolism assessed by compartmental modeling.

Whole-body modeling of in vivo leucine (an essential amino acid) metabolism is fundamentally difficult due to the complexity of the system. This has favored the use of two simple kinetic models, the so-called primary and reciprocal pool models, to interpret tracer data, but their domain of validity is uncertain. We define here the error of these two approaches by using comprehensive compartmental models of leucine metabolism as true representations of the leucine system. Of particular interest is the comparison of the two simple models with an 11-compartment model characterized by a rich intracellular compartmentation that has recently been proposed as a sound physiological description of the system. Formulas are derived that define in structural terms the error of the primary and reciprocal pool models.

Humans

Compartmental model of leucine kinetics in humans.

The complexity of amino acid and protein metabolism has limited the development of comprehensive, accurate whole body kinetic models. For leucine, simplified approaches are in use to measure in vivo leucine fluxes, but their domain of validity is uncertain. We propose here a comprehensive compartmental model of the kinetics of leucine and alpha-ketoisocaproate (KIC) in humans. Data from a multiple-tracer administration were generated with a two-stage (I and II) experiment. Six normal subjects were studied. In experiment I, labeled leucine and KIC were simultaneously injected into plasma. Four plasma leucine and KIC tracer concentration curves and label in the expired CO2 were measured. In experiment II, labeled bicarbonate was injected into plasma, and labeled CO2 in the expired air was measured. Radioactive (L-[1-14C]leucine, [4,5-3H]KIC, [14C]bicarbonate) and stable isotope (L-[1-13C]leucine, [5,5,5-2H3]KIC, [13C]bicarbonate) tracers were employed. The input format was a bolus (impulse) dose in the radioactive case and a constant infusion in the stable isotope case. A number of physiologically based, linear time-invariant compartmental models were proposed and tested against the data. The model finally chosen for leucine-KIC kinetics has 10 compartments: 4 for leucine, 3 for KIC, and 3 for bicarbonate. The model is a priori uniquely identifiable, and its parameters were estimated with precision from the five curves of experiment I. The separate assessment of bicarbonate kinetics (experiment II) was shown to be unnecessary. The model defines masses and fluxes of leucine in the organism, in particular its intracellular appearance from protein breakdown, its oxidation, and its incorporation into proteins. An important feature of the model is its ability to estimate leucine oxidation by resolving the bicarbonate model in each individual subject. Finally, the model allows the assessment of the domain of validity of the simpler commonly used models.

Adult

A compartmental model to quantitate in vivo glucose transport in the human forearm.

Glucose transport is a critical step in the control of glucose disposal that, until presently, has not been quantitated in vivo in humans. We have employed the perfused forearm and euglycemic insulin-clamp techniques in combination with a dual-tracer injection to measure basal and insulin-mediated glucose transport in six normal subjects. L-[3H]glucose, which is not transported, was used to trace extracellular glucose kinetics; 3-O-[14C]-methyl-D-glucose, transportable but not metabolizable, was used to monitor glucose movement across the cell membrane. After bolus intra-arterial injection of the two tracers, plasma samples were obtained every 15-30 s for 10 min from a deep forearm vein to determine the washout curves. A linear compartmental model was developed that accounts for blood flow heterogeneity. It consists of three parallel, two-compartment chains merging into the sampling compartment to which cellular compartments are appended. A priori identifiability analysis was performed. The uniquely identifiable parameterization includes the transport rate constants of glucose into and out of the cell. The model was identified using nonlinear least-squares parameter estimation. Transport parameters are estimated with very good precision, and their reproducibility is satisfactory. The model also allows the estimation of the mean arteriovenous transit times of both the extracellular and the transported tracer. The compartmental model provides a novel approach to investigate glucose transport in vivo in humans.

3-O-Methylglucose

Accessible pool and system parameters: assumptions and models.

Quantitative assessment of substrate metabolism from in vivo tracer kinetic data requires a model of the system, i.e., a hypothesis on the structure and functioning of the system. Some fundamentals of modeling important for studying intermediary metabolism in the steady state will be discussed. Accessible pool and system parameters are defined. Although the calculation of accessible pool parameters is structure-free, that of system parameters requires the use of non-compartmental or compartmental structures. Assumptions, bases for choice, and relative merits of these two modeling strategies are discussed. Glucose and leucine metabolism serve as prototypes to illustrate the theoretical points.

Glucose