Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

A dual modality computed mammotomography (CmT) and single photon emission computed tomography (SPECT) system for dedicated 3D breast imaging is in development. Using heavy K-edge filtration, the CmT component narrows the energy spectrum of the cone-shaped x-ray beam incident on the patient's pendant, uncompressed breast. This quasi-monochromatic beam is expected to improve discrimination of tissue with similar attenuation coefficients while restraining absorbed dose to below that of dual view mammography. Previous simulation studies showed the optimal energy that maximizes dose efficiency for a 50/50% adipose/glandular breast is between 30 and 40 keV. This study experimentally validates these results using pre-breast and post-breast spectral measurements made under tungsten tube voltages between 40 and 100 kVp using filter materials with K-edge values ranging from 15 to 70 keV. Different filter material thicknesses are used, approximately equivalent to the 200th and 500th attenuating value layer (VL) thickness. Cerium (K = 40.4 keV) filtered post-breast spectra for 8-18 cm breasts are measured for a range of breast compositions. Figures of merit include mean beam energy, spectral full-width at tenth-maximum, beam hardening and dose for the range of breast sizes. Measurements corroborate simulation results, indicating that for a given dose, a 200th VL of cerium filtration may have optimal performance in the dedicated mammotomography paradigm.

Biophysical Phenomena↗

Performance of dedicated emission mammotomography for various breast shapes and sizes.

We evaluate the effect of breast shape and size and lesion location on a dedicated emission mammotomography system developed in our lab. The hemispherical positioning gantry allows ample flexibility in sampling a pendant, uncompressed breast. Realistic anthropomorphic torso (which includes the upper portion of the arm) and breast phantoms draw attention to the necessity of using unique camera trajectories (orbits) rather than simple circular camera trajectories. We have implemented several novel three-dimensional (3D) orbits with fully contoured radius-of-rotation capability for compensating for the positioning demands that emerge from different breast shapes and sizes. While a general orbit design may remain the same between two different breasts, the absolute polar tilt range and radius-of-rotation range may vary. We have demonstrated that using 3D orbits with increased polar camera tilt, lesions near the chest wall can be visualized for both large and small sized breasts (325 ml to 1,060 ml), for a range of intrinsic contrasts (three to ten times higher activity concentration in the lesion than breast background). Overall, nearly complete 3D acquisition schemes yield image data with relatively high lesion SNRs and contrasts and with minimal distortion of the uncompressed breast shape.

Breast↗

Modeling the axial extension of a transmission line source within iterative reconstruction via multiple transmission sources.

Reconstruction algorithms for transmission tomography have generally assumed that the photons reaching a particular detector bin at a particular angle originate from a single point source. In this paper, we highlight several cases of extended transmission sources, in which it may be useful to approach the estimation of attenuation coefficients as a problem involving multiple transmission point sources. Examined in detail is the case of a fixed transmission line source with a fan-beam collimator. This geometry can result in attenuation images that have significant axial blur. Herein it is also shown, empirically, that extended transmission sources can result in biased estimates of the average attenuation, and an explanation is proposed. The finite axial resolution of the transmission line source configuration is modeled within iterative reconstruction using an expectation-maximization algorithm that was previously derived for estimating attenuation coefficients from single photon emission computed tomography (SPECT) emission data. The same algorithm is applicable to both problems because both can be thought of as involving multiple transmission sources. It is shown that modeling axial blur within reconstruction removes the bias in the average estimated attenuation and substantially improves the axial resolution of attenuation images.

Algorithms↗

An EM algorithm for estimating SPECT emission and transmission parameters from emissions data only.

A maximum-likelihood (ML) expectation-maximization (EM) algorithm (called EM-IntraSPECT) is presented for simultaneously estimating single photon emission computed tomography (SPECT) emission and attenuation parameters from emission data alone. The algorithm uses the activity within the patient as transmission tomography sources, with which attenuation coefficients can be estimated. For this initial study, EM-IntraSPECT was tested on computer-simulated attenuation and emission maps representing a simplified human thorax as well as on SPECT data obtained from a physical phantom. Two evaluations were performed. First, to corroborate the idea of reconstructing attenuation parameters from emission data, attenuation parameters (mu) were estimated with the emission intensities (lambda) fixed at their true values. Accurate reconstructions of attenuation parameters were obtained. Second, emission parameters lambda and attenuation parameters mu were simultaneously estimated from the emission data alone. In this case there was crosstalk between estimates of lambda and mu and final estimates of lambda and mu depended on initial values. Estimates degraded significantly as the support extended out farther from the body, and an explanation for this is proposed. In the EM-IntraSPECT reconstructed attenuation images, the lungs, spine, and soft tissue were readily distinguished and had approximately correct shapes and sizes. As compared with standard EM reconstruction assuming a fix uniform attenuation map, EM-IntraSPECT provided more uniform estimates of cardiac activity in the physical phantom study and in the simulation study with tight support, but less uniform estimates with a broad support. The new EM algorithm derived here has additional applications, including reconstructing emission and transmission projection data under a unified statistical model.

Algorithms↗

Analytical versus voxelized phantom representation for Monte Carlo simulation in radiological imaging.

Monte Carlo simulations in nuclear medicine, with accurately modeled photon transport and high-quality random number generators, require precisely defined and often detailed phantoms as an important component in the simulation process. Contemporary simulation models predominantly employ voxel-driven algorithms, but analytical models offer important advantages. We discuss the implementation of ray-solid intersection algorithms in analytical superquadric-based complex phantoms with additional speed-up rejection testing for use in nuclear medicine imaging simulations, and we make comparisons with voxelized counterparts. Comparisons are made with well-known cold rod:sphere and anthropomorphic phantoms. For these complex phantoms, the analytical phantom representations are nominally several orders of magnitude smaller in memory requirements than are voxelized versions. Analytical phantoms facilitate constant distribution parameters. As a consequence of discretizing a continuous surface into finite bins, for example, time-dependent voxelized phantoms can have difficulties preserving accurate volumes of a beating heart. Although virtually no inaccuracy is associated with path calculations in analytical phantoms, the discretization can negatively impact the simulation process and results. Discretization errors are apparent in reconstructed images of cold rod:sphere voxel-based phantoms because of a redistribution of the count densities in the simulated objects. These problems are entirely avoided in analytical phantoms. Voxelized phantoms can accurately model detailed human shapes based on segmented computed tomography (CT) or magnetic resonance imaging (MRI) images, but analytical phantoms offer advantages in time and accuracy for evaluation and investigation of imaging physics and reconstruction algorithms in a straightforward and efficient manner.

Algorithms↗

Intraoperative probes and imaging probes.

Intraoperative probes have been employed to assist in the detection and removal of tumors for more than 50 years. For a period of about 40 years, essentially every detector type that could be miniaturized had been tested or at least suggested for use as an intraoperative probe. These detectors included basic Geiger-Müller (GM) tubes, scintillation detectors, and even state-of-the-art solid state detectors. The radiopharmaceuticals have progressed from (32)PO(4)(-) injections for brain tumors to sophisticated monoclonal antibodies labeled with iodine-125 for colorectal cancers. The early work was mostly anecdotal, primarily interdisciplinary collaborations between surgeons and physical scientists. These collaborations produced a few publications, but never seemed to result in an ongoing clinical practice. In the mid 1980s, several companies offered basic gamma-detecting intraoperative probes as products. This led to the rapid development of radioimmunoguided surgery (RIGS) and sentinel node detection as regularly practiced procedures to assist in the diagnosis and treatment of cancer. In recent years intraoperative imaging probes have been developed. These devices add the ability to see the details of the detected activity, giving the potential of using the technique in a low-contrast environment. Intraoperative probes are now established as clinical devices, they have a commercial infrastructure to support their continued use, and there is ongoing research, both commercial and academic, that would seem to ensure continued progress and renewed interest in this slowly developing field.

Female↗