Increased myocardial ultrasonic reflectivity is associated with extreme hypertensive left ventricular hypertrophy: a tissue characterization study in humans.

We assessed myocardial reflectivity pattern in a large spectrum of left ventricular mass values, covering the extremes from absent to severe myocardial hypertensive hypertrophy. Quantitatively assessed ultrasonic backscatter is an index of ultrasonic tissue characterization directly related to the morphometrically evaluated collagen content in humans. We enrolled 88 essential hypertensives. With an echo prototype implemented in our Institute, integrated values of the radiofrequency signal of myocardial walls were obtained and normalized for those of the pericardium (Integrated Backscatter Index, IBI, %). Left ventricular mass index (LVMI) was measured by Devereux formula. There was a weak correlation between septal IBI and LVMI (r = 0.35; P < .001). On the basis of LVMI values, three groups of hypertensives were identified, with absent (Group I, n = 23; LVMI < 125 g/m2), mild to moderate (Group II, n = 44; LVMI from 125 to 174 g/m2), or severe (Group III, n = 21; LVMI > 175 g/m2) left ventricular hypertrophy. The Integrated Backscatter Index in the septum was lower in patients of Group I (IBI = 23.3% +/- 3.6%) and II (IBI = 26.5 +/- 7.6; P = NS v Group I), in comparison with patients of Group III (IBI = 31.1 +/- 5.9; P < .02 v II; P < .0001 v I). An increased myocardial wall reflectivity is detectable only in the presence of extreme forms of hypertensive left ventricular hypertrophy.

Adult↗

Heart involvement in systemic sclerosis: an ultrasonic tissue characterisation study.

BACKGROUND: Clinicoepidemiological findings indicate that symptomatic heart involvement in patients with systemic sclerosis (SSc) predicts a very poor prognosis. At necropsy studies, SSc heart involvement without significant coronary lesions is characterised by patchy myocyte necrosis and contraction band necrosis with collagen replacement leading to myocardial fibrosis. There is a discrepancy between the frequency of clinically evident myocardial disease (25%) and autoptical myocardial fibrosis (81%). OBJECTIVE: The aim of this study was to detect preclinical myocardial alterations in SSc patients by ultrasonic videodensitometric analysis. METHODS: Thirty five SSc patients (three male, aged 48.6 (11) SD years, range 22-65) with normal ventricular function and 25 age and sex matched healthy controls were studied. All patients had a negative maximal exercise stress; in all cases arterial hypertension, renal involvement, and diabetes were excluded. Echocardiographic images were digitised by a real time videodigitiser (Tomtec Imaging Systems). Quantitative texture analysis was performed on data from the septum and the posterior wall, obtaining mean gray level histogram (MGL) at both end-diastole (d) and end-systole (s). The cyclic variation index (CVI), was calculated according to the formula ((MGLd-MGLs)/MGLd) x 100. Left ventricular mass (LVM), body surface corrected, was calculated according to Penn convention. RESULTS: Comparable systolic and diastolic blood pressure, LVM, diastolic and systolic function were recorded in both SSc patients and controls. In contrast, in SSc patients the CVI, which is the expression of the intrinsic myocardial structural function, was significantly lower than in controls (septum: -18 (28)% v 35 (10)%, p < 0.0001; and posterior wall: -13 (32)% v 50 (20)%, p < 0.0001). Changes in cyclic echo amplitude, probably related to myocardial fibrosis, were detected in the large majority of SSc patients (88%). CONCLUSIONS: Ultrasonic videodensitometric analysis represents a non-invasive, feasible method that can detect early myocardial changes in SSc patients, which could be related to both fibrosis and microcirculatory abnormalities. Their potential evolution towards ventricular dysfunction and their link with cardiac sudden death, because of severe conduction system or rhythm disturbances, should be further investigated.

Adult↗

[Ultrasonic tissue characterization analysis in type 1 diabetes: a very early index of diabetic cardiomyopathy?].

BACKGROUND: Based on various epidemiological observations, it has been hypothesized that there is a "diabetic cardiomyopathy" strictly related to diabetes per se and probably due to an increase in the collagen content at the myocardial level, to microangiopathy or to complex alteration of myocardial metabolic pattern. Ultrasonic tissue characterization has recently been applied with different methodological approaches in order to identify early structural alterations of the myocardium. METHODS: We used two different methods of myocardial tissue characterization, i.e. integrated backscatter and videodensitometry, to analyze 26 type I diabetics without clinical symptoms, without hypertension or coronary artery disease, which were excluded on the basis of a negative exercise ECG, and in whom conventional echocardiographic parameters were normal. Seventeen healthy age- and sex-matched subjects were evaluated as the control group. RESULTS: Of the common left ventricular functional indexes, only E/A ratio (expression of global diastolic function) was lower in diabetics compared with controls (p < 0.01). The integrated backscatter index (IBI%) at the septum and posterior wall was significantly higher in diabetics as compared to controls, expressing an increased collagen content on a myocardial level. The cyclic variation index (%) of the mean gray level (videodensitometry) was significantly lower in diabetics in comparison with controls, both for the septum (p < 0.0001) and posterior wall (p < 0.002). This probably expresses an altered intrinsic myocardial contractility, due to an increase in myocardial collagen content and/or impairment of micro-circulatory function. CONCLUSION: In agreement with previous studies, we found an altered behavior in myocardial tissue reflectivity in type I diabetics. The real significance of this finding in the "normal" heart is the subject of intense debate. One hypothesis is that these findings could be considered a very early index of a "diabetic cardiomyopathy".

Adult↗

Increased myocardial echo density in left ventricular pressure and volume overload in human aortic valvular disease: an ultrasonic tissue characterization study.

Quantitatively assessed ultrasonic backscatter is an index of ultrasonic tissue characterization directly related to morphometrically evaluated collagen in human beings. Our objective was to assess myocardial reflectivity pattern of patients with severe left ventricular hypertrophy caused by either aortic stenosis (AS) or aortic regurgitation (AR). Ten patients with AS, 10 patients with AR, and 10 closely age- and gender-matched healthy controls were studied by two-dimensional Doppler echocardiography. By using an echocardiographic prototype, we performed a radiofrequency analysis to obtain quantitative operator-independent measurements of the integrated backscatter signal of the ventricular septum and the posterior wall (integrated backscatter index: IBI, expressed in percentage). All patients with stenosis or aortic insufficiency showed a normal regional and global resting systolic function (fractional shortening: AS = 36.0 +/- 6.6 versus AR = 40.3 +/- 6.2 versus control = 40.2 +/- 8.7; p = not significant [NS]) Left ventricular mass index (Devereux's formula) was markedly increased in patients with stenosis or aortic insufficiency (AS = 199.3 +/- 18 versus AR = 208.8 +/- 60 versus control = 97.3 +/- 11 g/m2; p < 0.0001). Myocardial echo density was increased in patients with stenosis or aortic insufficiency in comparison with controls, both in the septum (IBI%: AR = 40.7 +/- 7.9 versus AS = 33.4 +/- 4.2 versus control = 23.0 +/- 6.2; p < 0.0001) and in the posterior wall (IBI%: AR = 27.1 +/- 4.3 versus AS = 23.0 +/- 2.6 versus control = 15.0 +/- 4.2; p < 0.0001). No significant correlations were found between septal and posterior wall IBI and their thickness. Abnormally increased myocardial echo density--possibly related to disproportionate collagen deposition--can be detected in patients with pressure or volume overload caused by aortic valve disease and without overt systolic dysfunction.

Aged↗

Ultrasonic videodensitometric analysis of two different models of left ventricular hypertrophy. Athlete's heart and hypertension.

Absolute or relative increases in intramyocardial fibrosis accompany hypertrophy development in human hypertension. Myocardial texture analysis of two-dimensional echocardiographic gray-level distribution has been shown to identify alterations attributed to abnormal collagen content in several conditions. Therefore, this echocardiographic tool might help to identify those hypertensive individuals with abnormal interstitial collagen deposition, a condition that may promote and/or aggravate morbidity in this group of people who are at high risk for cardiovascular events. We compared male essential hypertensive subjects who had marked cardiac hypertrophy (left ventricular mass index adjusted for height > 2 SD of mean of control group) (group 1) with normotensive elite veteran athletes who had comparable cardiac hypertrophy (group 2) and sedentary normotensive subjects as controls (group 3). The groups (n = 14 each) were matched for age (+/- 2 years) and sex. We analyzed echocardiographic digitized data quantitatively by means of a calibrated 256 gray level digitization system to calculate midseptal and midposterior end-diastolic and end-systolic mean gray levels and to derive the so-called cyclic variation index, ie, the percent mean gray level variation during the cardiac cycle. Echocardiographic parietal and septal thicknesses and masses were evaluated according to the Penn convention. Left ventricular mass index (adjusted for height) overlapped between groups 1 and 2 (187.1 +/- 17.5 and 181.3 +/- 19.3 g/m, respectively; P = NS), whereas it was obviously smaller in control subjects (93.1 +/- 18.6 g/m; P < .001 for both). According to inclusion criteria, both septal and posterior wall thicknesses were comparable in athletes and hypertensive subjects, and they were higher than in the control group (P < .0001). The hypertensive subjects showed a significantly lower cyclic variation index than the control and athlete groups for both the septum (P < .001) and posterior wall (P < .001); no statistical difference was found between athletes and control subjects for this parameter. In conclusion, abnormalities of two-dimensional echocardiographic gray-level distribution are present in hypertensive hypertrophied individuals but seem unrelated to the degree of echocardiographic hypertrophy as such. An altered collagen network distribution or a decrease in capillary distribution in severe myocardial hypertrophy, secondary to pressure-volume overload in hypertension with other yet unknown mechanisms, could help to explain our findings. Further work is needed to establish the prognostic, clinical, and therapeutic implications of these findings.

Analysis of Variance↗

A videodensitometric study of transmural heterogeneity of cyclic echo amplitude variation in human myocardium.

The aims of this study were: (1) to assess whether variations in cyclic echo amplitude might be detected across the human myocardium by videodensitometric analysis of images obtained with epicardial echocardiography; and (2) to explore the possible relation between cyclic gray level variation and left ventricular (LV) hypertrophy and function. Experimental studies show that transmural differences in contractile performance across the normal myocardium are paralleled by differences in the cyclic (diastolic-to-systolic) variation of myocardial echo amplitude. Thirty-three patients (aged 60 +/- 11 years) undergoing cardiac surgery were studied by intraoperative epicardial echocardiography. LV mass index as normal (<110 g/m2 in women, <131 g/m2 in men) in 10 patients and increased in 22. Two-dimensional echocardiographic images were obtained with a 5 MHz transducer and digitized off-line. Videodensitometric analysis was performed at end-diastole and end-systole with regions of interest across the septal and posterior wall. The cyclic variation was more pronounced in the left than in the right septal subendocardium (31% +/- 14% vs 16% +/- 14% <0.01) and higher in the subendocardial than in the subepicardial layer of the posterior wall (30% +/- 21% vs 23 +/- 18%, p <0.01). Cyclic variation of the left septal subendocardium was higher in 11 patients with nonhypertrophic ventricles than in 22 with hypertrophic left ventricles (42% +/- 15% vs 27% +/- 12%; p <0.01). The percent cyclic variation of the left septal subendocardium appeared to be much more tightly related to percent systolic thickening in patients with eccentric LV hypertrophy (r=0.80 p <0.01) than in patients with concentric LV hypertrophy (r=0.27, p=0.9) or normal LV mass (r=0.43, p=0.2). A cyclic gray level variation can be consistently detected in different human myocardial regions and layers. It is more obvious in the subendocardial than in the subepicardial layer, and in nonhypertrophic than hypertrophic ventricles. The cyclic subendocardial variation is tightly related to regional systolic thickening in patients with eccentric LV hypertrophy.

Aged↗

Cyclic variation in myocardial gray level as a marker of viability in man. A videodensitometric study.

Experimental and human studies have shown that a preserved cyclic (diastolic-to-systolic) echoreflectivity variation, assessed by radiofrequency sampling of backscatter signal with non-commercially available prototypes, identifies viability in a myocardial segment with a resting dyssynergy. The objective of this study was to assess whether a videodensitometric analysis of myocardial gray level variation during cardiac cycle might identify viable but dyssynergic myocardium in a clinical setting. Thirty-four patients with a resting dyssynergy (akinesis in 26, marked hypokinesis in eight) in the septum and/or inferno-posterior wall were evaluated by videodensitometry. All echo studies were performed with commercially available instruments in the long axis parasternal view, with quantitative analysis of gray levels performed off-line on digitized images. Segmental wall motion was assessed with a 16 segment model of the left ventricle, each scored from 1, normal, to 4, dyskinetic. A follow-up echo study was obtained in all patients > 4 weeks after successful revascularization (in 22 by angioplasty, in 12 by bypass surgery). Two groups of segments were identified: 18 viable segments (contractile improvement of 1 grade or more in resting function after revascularization); 16 necrotic segments (no contractile improvement in resting function after revascularization). The % cyclic variation was higher in viable vs necrotic segments (26 +/- 16 vs 1 +/- 13%, P < 0.01), in spite of similar % systolic thickening (5 +/- 5 vs 4 +/- 6%, P = ns) and end-diastolic thickness (10 +/- 2 vs 10 +/- 2 mm, P = ns). When individual patient analysis was performed, % cyclic variation was below the 95% confidence limits obtained from normal control regions (n = 34; % cyclic variation = 38 +/- 14) in two out of 18 viable and in 14 out of 16 necrotic segments. A cut-off of > or = 9.4% cyclic variations in a dyssynergic segment yielded 89% sensitivity and 88% specificity for predicting functional recovery following successful revascularization. In conclusion, viable dyssynergic myocardial segments show a cyclic gray level variation at rest, which can be detected by simple videodensitometric analysis, much less technologically demanding than radiofrequency backscatter evaluation.

Cell Survival↗

Ultrasonic videodensitometric analysis in type 1 diabetic myocardium.

OBJECTIVE: To test the hypothesis that quantitative analysis of two-dimensional echocardiographic gray-level distributions could allow one to detect the early changes in acoustic properties of human diabetes myocardium differentiating it from normal myocardium. METHODS: We evaluated, by two-dimensional echocardiography, 28 asymptomatic type 1 insulin-dependent diabetic patients with normal ventricular function (group A) and 15 age- and sex-matched healthy controls (group B). By selection, all of the diabetics were normotensive and had a negative maximal exercise stress. Echocardiographic images were digitized by using a calibrated digitization system. Quantitative texture analysis was accomplished on data from the septum and posterior wall both at end-diastole and at end-systole. The following parameters were obtained: the mean gray level of the regions of interest, and its absolute SD, skewness, kurtosis, and cyclic variation index. RESULTS: The main result of this study was that the cyclic variation indices of the echo amplitudes of the septum and posterior wall in the diabetic group were significantly lower than those in controls (P < 0.001 and P < 0.002, respectively). Furthermore, the diabetic group had a significantly higher mean gray level of the septum [group A 54.3 +/- 22.5 (mean +/- SD) versus group B 39.7 +/- 9.8, P < 0.03] at end-diastole. The mean gray-level of the posterior wall was similar in the two groups, both at end-diastole and at end-systole. CONCLUSION: Alterations of cyclic echo amplitude (possibly related to collagen deposition) can be detected in asymptomatic diabetic patients with normal resting function. Theoretically, this finding might be considered an early preclinical alteration, potentially related to subsequent development of "diabetic cardiomyopathy'.

Adult↗

Quantitative assessment of coronary atherosclerotic plaque profile by morphometric analysis of angiographic images.

Coronary plaque morphology (simple or complex) has a recognized clinical, pathophysiologic, and prognostic importance, but its routine use is hampered by the subjective and qualitative nature of the assessment. The aim of this study was to assess the feasibility and accuracy of mathematical, objective, operator-independent assessment of plaque morphology, by means of algorithms based on vector and fractal analysis, previously developed for describing continuous curves. Twenty coronary angiograms were analyzed: 10 with "simple-type" stenosis (defined according to Ambrose type I pattern, Group I) and 10 with "complex-type" stenosis (Ambrose type II pattern, Group II). Five morphometric parameters effectively separated simple and complex-type stenosis: peaks/cm (Group I = 0.24 +/- 0.31 vs Group II = 2.46 +/- 1.83, P < .01); summed maximum error/cm (I = 0.94 +/- 1.19 vs II = 4.53 +/- 0.56, P < .01); integrated error/cm (I = 0.22 +/- 0.27 vs II = 2.25 +/- 1.68, P < .01); number of features/cm (I = 0.02 +/- 0.05 vs II = 1.19 +/- 0.65, P < .01); standard deviation curvature (I = 0.07 +/- 0.01 vs II = 0.22 +/- 0.21, P = 0.06). The scaled edge-length ratio-the only parameter based on fractal analysis-was not different between the two groups (I = 1.03 +/- 0.01 vs II = 1.13 +/- 0.10, P = ns). Hence, a quantitative description of plaque morphology is feasible and allows an effective discrimination of simple and complex plaque profiles with morphometric parameters based on vector analysis.

Coronary Angiography↗

Dobutamine stress: effects on regional myocardial blood flow and wall motion.

OBJECTIVES: This investigation studied the relation between regional myocardial blood flow and left ventricular function during dobutamine stress in patients with coronary artery disease. BACKGROUND: Dobutamine stress is becoming more frequently used as an alternative to dynamic exercise in patients with ischemic heart disease. METHODS: We studied 12 patients with coronary artery disease. Dobutamine was infused from 5 micrograms/kg body weight per min up to 40 micrograms/kg per min or until chest pain or other intolerable side effects. Regional myocardial blood flow was measured with positron emission tomography and oxygen-15-labeled water. Regional wall motion was assessed in three short-axis slices by magnetic resonance imaging. Each slice was subdivided into four regions: septal, anterior, lateral and inferior. A total of 140 regions were suitable for comparison. RESULTS: During stress, new wall motion abnormalities developed in 27 regions. Myocardial blood flow (mean +/- SD) increased in 113 regions that did not develop wall motion abnormalities (0.98 +/- 0.26 [baseline] vs. 1.98 +/- 0.87 [dobutamine] ml/min per g, p < 0.001), whereas it did not change significantly in regions with stress-induced wall motion abnormalities (1.00 +/- 0.28 [baseline] vs. 1.30 +/- 0.62 [dobutamine] ml/min per g, p = NS). An absolute decrease in myocardial blood flow below the value at rest was observed in seven segments that developed wall motion abnormalities during stress. CONCLUSIONS: The normal functional response to dobutamine stress is paralleled by an increase in coronary flow, whereas mechanical dysfunction is accompanied by a blunted increase, or even a paradoxic decrease, in regional coronary flow.

Adult↗

Increased echodensity of myocardial wall in the diabetic heart: an ultrasound tissue characterization study.

OBJECTIVES: We sought to characterize myocardial echodensity in asymptomatic patients with insulin-dependent diabetes and normal conventional two-dimensional echocardiographic findings to determine whether ultrasound tissue characterization can detect ultrastructural changes in myocardium, such as an increase in collagen content. BACKGROUND: Fibrosis alters the acoustic properties of the heart in animals and humans, and these changes are detectable by cardiac tissue characterization with ultrasound. Early changes detected in the diabetic heart include increased interstitial collagen deposition. METHODS: Using two-dimensional echocardiography, we evaluated 26 asymptomatic patients with insulin-dependent diabetes with normal regional and global rest function, and 17 age- and gender-matched control subjects. By selection, all diabetic patients were normotensive and had negative maximal exercise stress test results to avoid the confounding effects of hypertension and coronary artery disease. Using an echocardiographic instrument implemented at the Institute of Clinical Physiology, we performed an on-line radiofrequency analysis to obtain quantitative operator-independent measurements of the integrated back-scatter signal of the ventricular septum and posterior wall. The integrated values of the radiofrequency signal from the myocardial wall were normalized for those from the pericardial interface and were expressed as percentages (integrated backscatter index). RESULTS: Diabetic patients showed a significant increase in myocardial echodensity both in the septum ([mean +/- SD] 36.6 +/- 8.1 vs. 23.6 +/- 4.4, p < 0.0001) and posterior wall (21.2 +/- 5.3 vs. 18.4 +/- 3.7, p < 0.001). By individual patient analysis, 17 patients exceeded the 95% confidence limits for normal myocardial echocardiographic reflectivity found in normal subjects, and only 3 had a relatively abnormal transmitral Doppler filling pattern (E/A ratio), mainly consisting of an abnormally increased late peak flow velocity (65% vs. 11%, p < 0.001). The increased myocardial intensity was similar in patients with (n = 16) and without (n = 10) noncardiac complications, such as retinopathy or nephropathy (37.5 +/- 7.9% vs. 35.0 +/- 8.3%, p = 0.35). CONCLUSIONS: Abnormally increased myocardial echodensity, possibly related to collagen deposition, can be detected in asymptomatic diabetic patients with normal rest function. Theoretically, this finding might be considered a very early preclinical alteration potentially related to subsequent development of diabetic cardiomyopathy.

Adult↗

Quantitative aspects in myocardial contrast echocardiography.

Myocardial tissue perfusion is not currently quantified in the clinical setting. Thus the aim of this paper is to review the quantitative information on myocardial perfusion provided by contrast echocardiography. In a circulatory model-without the capillary network interposed between injection and sampling point of contrast-the transit time of microbubbles (source of the echo contrast effect) is inversely related to absolute flow, thus providing accurate quantitation. A similar situation is represented by blood flow inside a vessel or a cardiac cavity, where, if the prerequisites for quantitation are respected, it is possible to measure blood flow by contrast echocardiography. In the coronary circulation, the transit time of contrast microbubbles varies according to their interaction with coronary microcirculation, and to the characteristics of contrast agents as flow tracers. Echo contrast agents with small microbubbles have been injected into the coronary branches of experimental animals, under both coronary autoregulation and maximal coronary dilation, providing good estimates of coronary blood flow. The accuracy of these measurements might improve when new contrast agents, with characteristics closer to those of a flow tracer, are available. If a tracer is injected before a bifurcation, and provided it mixes adequately, the amount of tracer distributed to each branch is proportional to the corresponding blood flow. A similar situation is encountered when an echo contrast agent is injected into the aortic root or into the left main coronary artery. Here, the ratio between myocardial signal intensity in the different perfusion territories reflects the corresponding ratio of blood flows. The validity of this approach has been previously demonstrated in experimental animals and validated in patients with coronary stenoses. The injection of contrast agents into the coronary circulation at baseline and under coronary hyperaemia has the potential for measuring coronary blood flow reserve. However, what is still unclear is whether contrast echo changes reflect changes in coronary blood flow (i.e. flow reserve), coronary blood volume (i.e. coronary recruitment) or both, and also whether they influence the different types of contrast agent. Finally, myocardial contrast echocardiography can provide information on the spatial distribution of myocardial perfusion, i.e. the presence, site and extent of perfused myocardium. Thus, in models where myocardial perfusion may be either present or absent, contrast echo can provide an accurate estimate of perfusion abnormalities.

Blood Flow Velocity↗

In vivo ultrasonic parametric imaging of carotid atherosclerotic plaque by videodensitometric technique.

Extensive experimental and clinical data show that the ultrasonic image conveys information on the biochemical composition of the atherosclerotic plaque, ie, the relative content of lipids (hypoechoic), fibrous tissue (hyperechoic), and calcific deposits (very echogenic with shadowing). A more dishomogeneous echo structure of the plaque is also more often associated with clinically complicated carotid plaques. To date, however, the assessment of plaque density and homogeneity by transcutaneous B-mode imaging remains subjective and qualitative. The aim of this study was to assess whether plaque echodensity and homogeneity might be established on a more objective and quantitative basis by description of the spatial distribution of echo amplitude (referred to as tissue texture) applied to digitized images, obtained with commercially available B-mode transcutaneous imaging systems. A total of 47 B-mode images derived from echotomographic studies in 10 patients were digitized off line. For each region of interest, a set of first-order (mean gray level, standard deviation, skewness, kurtosis: mathematical descriptors of the shape of the frequency distribution of gray-level histogram) and of second-order (entropy, angular moment: mathematical descriptors of the spatial distribution of gray levels within the region of interest) textural parameters were evaluated. The visual, concordant reading by two independent, experienced observers assigned the plaques on the basis of qualitatively assessed echodensity to three groups: "soft" (n = 18), "fibrotic" (n = 20), "calcific" (n = 9). Regarding spatial gray-level distribution, 46 plaques would be separated into "homogenous" (n = 17) and "dishomogeneous" (n = 29). On digitized images, the normalized mean gray level was the most effective first-order textural parameter for distinguishing soft (24.2 +/- 12.4 arbitrary units in a zero to 255 scale) from fibrotic (64.5 +/- 16.4) and calcific plaques (125.3 +/- 24.5), P < 0.01 for all intergroup differences. "Homogeneous" plaques were separated from "heterogeneous" ones on the basis of entropy (5 +/- 1 vs 7.9 +/- 9.7; P < 0.01), whereas the values of angular second moment overlapped (1.542E-3 + 1.334E-3 vs 5.181E-4 +/- 2.5615E-4, P = ns). In conclusion, quantitative texture analysis of ultrasonic images derived from transcutaneous, high-resolution, commercially available B-scan systems is feasible in man and provides a quantitative operator-independent assessment of plaque echodensity and homogeneity.

Arteriosclerosis↗

[Late thrombolysis in acute myocardial infarct. Demonstration of myocardial tissue salvage by the assessment of pre- and post-thrombolytic perfusion and left ventricular function].

BACKGROUND: Pre and post treatment perfusion scintigraphy with Tc-99m-sestamibi is an accurate method to evaluate the effectiveness of thrombolytic therapy in patients with acute myocardial infarction. In the present study this method was used to verify whether thrombolytic therapy performed late (6 to 24 hours) after symptoms onset was still able to produce significant salvage of jeopardized myocardial tissue. METHODS: Fifteen patients (mean age 60.9 +/- 9 years) admitted to CCU 8-23 hours (mean 13.2 +/- 4 hours) after symptoms onset of their first acute myocardial infarction were studied. Both myocardial perfusion and left ventricular function were assessed before and after thrombolysis. Myocardial perfusion was studied using Tc-99m-sestamibi Single Photon Emission Tomography (SPET) before (pre-lysis SPET), 4.4 +/- 0.9 days (post-lysis SPET A) and 32 +/- 6 days (post-lysis SPET B) after thrombolysis. Uptake defects were graded from 0 to 4 using a 20-segment scheme. Regional ventricular function was evaluated using two-dimensional echocardiography before (pre-lysis ECHO), simultaneously with post-lysis SPET A (post-lysis ECHO A) and 32 +/- 4 days after treatment (post-lysis ECHO B); asynergy was graded from 1 to 4. Global left ventricular function was estimated using gated blood pool imaging and measuring the ejection fraction (EF) 5.3 +/- 1 (GBP 1) and 32 +/- 4 days after treatment (GBP 2). Within 6-9 days of admission all patients underwent coronary angiography. RESULTS: In pre-lysis SPET all patients had uptaken defects (score range 17-52, mean 34.6 +/- 12). According to the comparison between pre-lysis SPET and post-lysis SPET A, patients were divided into two groups: 7 patients with perfusion recovery (Group I) and 8 patients with absent or minimal perfusion recovery (Group II). In Group I the mean uptaken score decreased significantly (from pre-lysis SPET 34.2 +/- 12 to post-lysis SPET A 21.7 +/- 7, p < 0.05); in Group II the uptaken score remained unchanged (from pre-lysis SPET 34.8 +/- 12 to post-lysis SPET A 33.6 +/- 12, ns). In post-lysis SPET B both groups showed a defect reduction compared to post-lysis SPET A; however, the defect score of SPET B in Group I was significantly lower than that in Group II (18.7 +/- 16 vs 30.1 +/- 10, p < 0.05). The asynergic score in pre-lysis ECHO was the same in the two groups (19.5 +/- 4); in post-lysis ECHO A no significant decrease was observed in the two groups. In post-lysis ECHO B a significant decrease was seen in Group I (14.8 +/- 5, p < 0.05 vs pre-lysis ECHO and vs post-lysis ECHO A), but not in Group II (19.8 +/- 5, ns); the asynergic score in post-lysis ECHO B was significantly lower in Group I than in Group II (p < 0.05). In GBP 1 the EF was 38% +/- 6 in Group I and 40% +/- 6 in Group II (ns). In GBP 2 a significant increase was registered in Group I (47% +/- 10, p < 0.05), whereas in Group II the EF remained unchanged (40% +/- 6, ns). Coronary angiography showed a patent infarct related vessel in all Group I patients and in 2 Group II patients (p < 0.05). CONCLUSIONS: These results show that in patients with acute myocardial infarction treated with thrombolysis late after symptoms onset it is still possible to obtain an effective reperfusion and the consequent salvage of jeopardized tissue, as demonstrated by the recovery of both regional and global left ventricular function.

Aged↗

Increased echodensity of transiently asynergic myocardium in humans: a novel echocardiographic sign of myocardial ischemia.

OBJECTIVES: This study was conducted to establish whether changes in myocardial texture can be observed in humans by transthoracic echocardiography during ischemic episodes of different severity and duration induced by various pathogenetic mechanisms. BACKGROUND: Increased echo-reflectivity of ischemic myocardium has been detected in experimental animals by epicardial echocardiography and by backscatter evaluation. METHODS: Transthoracic two-dimensional echocardiographic monitoring with a commercially available electronic sector scanner (2.25- or 3.5-MHz transducer) was performed during 35 episodes of transient myocardial ischemia induced by ergonovine in patients with vasospastic angina (n = 9), by dipyridamole in patients with angiographically assessed coronary artery disease (n = 11) and by balloon occlusion during coronary angioplasty (n = 15). Quantitative texture analysis of gray levels was performed off-line on digitized images during rest conditions, ischemia and the recovery phase in regions showing normal contraction at rest, obvious dyssynergy during ischemia and normal contraction in the recovery phase. In each condition, a control region with normal contraction throughout the study was also evaluated. RESULTS: Chest pain occurred in 23 of the 35 episodes; electrocardiographic (ECG) changes were present in 26 episodes, and consisted of ST segment elevation in 13, ST segment depression in 10 and pseudonormalization of a basally negative T wave in 3. The duration of ischemic episodes was 67 +/- 53 s by symptomatic criteria and 91 +/- 52 s by ECG criteria. The risk region showed an increased end-diastolic mean gray level amplitude in a.u. (arbitrary units) during ischemia (57 +/- 19) compared with rest (38 +/- 15) and recovery (38 +/- 18, p < 0.01). No significant changes were detected in the control region (rest 36 +/- 16 vs. ischemia 34 +/- 18 vs. recovery 31 +/- 13, p = NS). The percent increase in mean gray level was similar in the various types of stress employed (ergonovine, dipyridamole or angioplasty) and was not significantly correlated with either the duration of ST segment shift (r = 0.05, p = NS) or the severity of dyssynergy evaluated semiquantitatively by means of the wall motion score (r = 0.28, p = NS). In the 15 balloon occlusions performed in six patients during coronary angioplasty, the increased echoreflectivity of the risk zone was already evident during echocardiographic sampling performed after 10 +/- 4 s of occlusion (rest 35 +/- 9 vs. 53 +/- 10 a.u., p < 0.01) when no dyssynergy could be detected by quantitative wall motion analysis (percent area change by fixed center of mass reference system 31 +/- 10% at rest vs. 32 +/- 11% after 10 s of occlusion, p = NS). CONCLUSIONS: Transient short-lasting myocardial ischemia is associated with an abrupt increase in myocardial echodensity detectable by videodensitometric analysis applied to standard transthoracic echocardiographic images and is largely independent of the underlying pathogenetic mechanism (reduced blood supply or flow maldistribution with coronary stenosis). During controlled coronary occlusion, increased echodensity precedes the onset of regional dyssynergy.

Analysis of Variance↗

In vivo radiofrequency-based ultrasonic tissue characterization of the atherosclerotic plaque.

BACKGROUND AND PURPOSE: The ultrasonic image can offer unique information on the composition of atherosclerotic plaque, ie, the relative content of lipids, fibrous tissue, and calcific deposits. To date, however, the echographic assessment of plaque structure is based on a subjective, qualitative evaluation of the bidimensional images. We evaluated the feasibility and accuracy of assessing, in vivo, the acoustic properties of arterial carotid plaques by means of a suitably modified echographic apparatus allowing direct access to the radiofrequency signal. METHODS: In 15 patients undergoing carotid thromboendarterectomy, the ultrasonic findings in 70 discrete sites (within the plaque, n = 54; normal sites, n = 11; or intraluminal thrombi, n = 5) were correlated with the histological analysis (hematoxylin-eosin and Mallory trichrome stains) independently performed on the arterial samples. The pathological examination was carried out at a similar level of the insonation; the sites analyzed within the plaque were chosen because of their uniform echoic characteristics. In each ultrasonic region of interest selected from the echographic image, the integrated amplitude of the rectified radiofrequency signal was measured as the integrated backscatter index. RESULTS: The intimal-medial layer of normal carotid wall (n = 11) exhibited values of -32.5 +/- 9.4 dB. The integrated backscatter index in fatty sites (n = 11, -40.3 +/- 5.4 dB) differed from that of fibrous (n = 12, -23.8 +/- 5.0 dB) and calcified (n = 26, -11.5 +/- 5.2 dB, P < .01 for all intergroup differences) sites. Intraluminal thrombotic sites (n = 5, -42 +/- 5.1 dB, P < .01) differed from fibrous and calcified subsets (P < .01) but overlapped (P = NS) with fatty sites. Histological sampling also showed two sites of intraplaque hemorrhage that exhibited very low backscatter values (-53 and -58 dB) and three fibrofatty sites showing backscatter values (-28, -28, and -32 dB) intermediate between the fibrous and the fatty subsets. CONCLUSIONS: Quantitative analysis of integrated backscatter of the arterial wall is feasible in humans and provides an operator-independent assessment of plaque echoic structure. In particular, integrated backscatter is effective in distinguishing lipidic, fibrotic, and calcific components in human atherosclerotic plaques.

Arteriosclerosis↗