Measurement of estrone-3-glucuronide and pregnanediol-3 alpha-glucuronide in early morning urine samples to monitor ovarian function.

The determination of the concentration of estrone-3-glucuronide and pregnanediol-3 alpha-glucuronide has been performed by a chemiluminescent immunoassay in early morning urine samples of 14 normal menstruating women and 11 women affected by luteal phase defect. The early morning urine samples were daily collected for an entire menstrual cycle. We have employed a timed and measured volume collection procedure as correction factor. The integrated values of the hormonal data in definite time intervals were used to create a nomogram. By means of this method, it was possible to completely separate normal from luteal insufficiency subjects and to distinguish two different types of luteal phase defects. Moreover, the same approach was applied to the study of the role and the frequency of luteal phase defect in 15 patients affected by habitual abortion and in 17 premenopausal women who had undergone quadrantectomy for T1a No Mo breast cancer. A luteal phase defect was detected in nine of the aborting patients (60%) and in eight women affected by breast cancer (47%). Finally estrone-3-glucuronide was measured in early morning urine samples of 96 prepubertal and pubertal girls in different pubertal stages and in one patient affected by precocious puberty, before and during an agonist GnRH treatment. The urinary test of ovarian function seems to be suitable for diagnostic purposes and for clinical studies.

Abortion, Habitual↗

A chemiluminescent immunoassay for the direct measurement of urinary 5 alpha-androstane-3 alpha, 17 beta-diol-glucuronide in urine.

We described a chemiluminescent immunoassay (CIA) for 5 alpha-androstane-3 alpha, 17 beta-diol-glucuronide (3 alpha-diol-G) in human diluted urine. This method allowed the direct measurement in 1 microliter of urine avoiding the hydrolysis and extraction steps for sample pretreatment commonly used in routine methods. The hapten 3 alpha-diol-G was synthesized by a Koenigs-Knorr reaction. The immunogenic complex, 3 alpha-diol-G conjugated to bovine serum albumin (BSA), was employed to induce the formation of specific antibodies in New Zealand rabbits. In addition, the required chemiluminescent (CL) tracer was prepared. The characteristics of the antibody was determined as regard to specificity and sensitivity and the precision of the assay methods established. In 22 hirsute women affected by polycystic ovarian syndrome we found 3 alpha-diol-G values significantly (p less than 0.01) higher (146.28 +/- 73.77 micrograms/g of creatinine; mean +/- SD) than those observed in normal women (72.1 +/- 32.58 micrograms/g of creatinine; mean +/- SD).

Adult↗

A chemiluminescent method for the measurement of pregnanetriol-3 alpha-glucuronide in human diluted urine.

Pregnanetriol-3 alpha-glucuronide (PTG) is the majority urinary metabolite of 17-hydroxyprogesterone (17OHP) and it typically increases in the commonest form of congenital adrenal hyperplasia (CAH), due to 21 hydroxylase deficiency. We developed a simple chemiluminescent immunoassay for the direct measurement of PTG in diluted urine in order to avoid the preliminary hydrolysis and extraction steps that are usually employed in gas-liquid chromatographic methods. The immunogenic complex PTG-bovine-serum-albumin was used to induce the formation of specific antibodies in New Zealand rabbits. In addition, PTG was conjugated to aminoethylethylisoluminol and the resulting tracer was characterized by mass spectrometry and used to monitor the immunological reaction. The characteristics of the antibody were determined with regard to specificity and sensitivity. The precision of the assay method was also established. PTG excretion was studied before and after the ACTH stimulation test (1 mg synthetic ACTH i.m.) in 11 normal women and in one subject affected by CAH due to 21-hydroxylase deficiency. PTG levels well correlated with 17OHP plasma concentrations both under basal and stimulated conditions, in normal women as well as in the patient affected by CAH.

17-alpha-Hydroxyprogesterone↗

Cholinergic and noradrenergic denervations decrease labelled purine release from electrically stimulated rat cortical slices.

The origin of cortical purine release was investigated by measuring [3H]purine release from electrically stimulated cortical slices of rats after neurotoxic lesions of cholinergic, noradrenergic and serotoninergic pathways innervating the cortex. Purines were labelled by incubating the cortical slices with [3H]adenine. The 3H efflux at rest and during stimulation, analysed by high performance liquid chromatography, consisted of adenosine, inosine, hypoxanthine and a small amount of nucleotides. Twenty days after unilateral or bilateral lesion of the nucleus basalis a marked decrease in choline acetyltransferase activity was associated with a decrease in [3H]purine release. A linear relationship was found between the decrease in choline acetyltransferase activity and [3H]purine release. A partial recovery in both choline acetyltransferase activity and [3H]purine release was observed eight months after the lesion. Twenty days after intra-cerebroventricular injection of 6-hydroxydopamine a 59% decrease in cortical noradrenaline content was associated with a 44% decrease in [3H]purine release. Conversely, no change in [3H]purine release was found in rats in which a 89% decrease in cortical serotonin content was induced by intra-cerebroventricular injection of 5,7-dihydroxytryptamine. The decrease in [3H]purine release after the lesion of the cholinergic and noradrenergic pathways may depend on metabolic changes, a loss of a stimulating influence of acetylcholine and noradrenaline or may indicate a release of [3H]purine from cholinergic and noradrenergic fibres.

Adenosine↗

Immunometric assay for lutropin (hLH) based on the use of universal reagents for enzymatic labelling and magnetic separation and monitored by enhanced chemiluminescence.

A solid-phase immunometric assay of human lutropin (hLH) is described. Two different anti-hLH antibodies were utilized as capture antibodies, and anti-IgG antibodies covalently coupled to magnetic particles and horseradish peroxidase, respectively, served as 'universal' detection reagents. An anti-hLH antibody raised in rabbits was incubated with a goat anti-rabbit IgG covalently bound to magnetic particles. The resulting complex was added to a separately incubated mixture of hLH and monoclonal anti-hLH antibody. Following incubation, the immunocomplex was sedimented in a magnetic field and the supernatant discarded. Finally a sheep anti-mouse antibody (F(ab')2 fragment) conjugated to horseradish peroxidase as label was added. Following a further incubation, the particles were sedimented in the magnetic field and washed. The hLH content of the sample was quantitated by measuring 'enhanced chemiluminescence'. The sensitivity of the assay was 2.5 +/- 0.9 IU/l (mean +/- SD), the within-run variation ranged from 7.9 to 11%, the between-run variation from 12.9 to 19.8%. Cross-reaction with hFSH or hTSH could not be detected, but was approximately 0.1% with hCG. The results correlated well with those obtained by radioimmunoassay (r = 0.84).

Antibodies, Anti-Idiotypic↗

Measurement of glucuronometabolites of 17 beta-estradiol and progesterone in diluted overnight urine. An approach to the study of luteal insufficiency.

The determination of the concentrations of estrone-3-glucuronide, pregnanediol-3-glucuronide and luteinizing hormone has been performed in early morning urine samples of 14 normal menstruating women using a timed and measured volume urine collection procedure. In order to investigate the variability of the urinary hormonal concentrations due to day-to-day differences in diuresis, the absolute hormonal concentrations have been corrected either for the urinary creatinine excretion or for the volume of urine voided during the night. The results demonstrate that both correction factors are able to reduce substantially the coefficient of variation values in comparison to the absolute hormonal concentrations. The urinary test of ovarian function has been performed in 11 infertile women affected by luteal insufficiency using the same procedure, and the hormonal profiles showed some alterations in both estrone-3-glucuronide and pregnanediol-3-glucuronide concentrations in comparison to the hormonal profiles of the normal subjects. Such alterations were significant in the single subject when integrated values of the hormonal data in defined time intervals were investigated.

Adult↗

Chemiluminescence immunoassay for somatomedin C in serum.

To select the best tracer for use in a competitive immunoassay, we conjugated human somatomedin C (SmC) to various chemiluminescent compounds via two different synthetic pathways. Naphthylhydrazides and arylhydrazides, used as the labels, were incorporated via their imidate or their succinimide esters. Conjugating the carboxy terminal of (amino ethyl)ethyl-isoluminol to SmC via a succinimide linkage supplied the most sensitive detection limit and the most immunoreactive conjugate. We developed an immunoassay based on the use of this conjugate, and evaluated dextran-coated charcoal, second-antibody precipitation, and solid-phase immunoprecipitation for separating bound and free label. This chemiluminescent method has a detection limit of 16 pg per tube, and it is accurate and precise. Correlation studies with a conventional radioimmunoassay (x) for SmC gave the following regression equation: y = 0.66x + 3.76 (r = 0.953, n = 30); the slight discrepancies between the two methods are probably ascribable to the use of different antibodies. We thus propose this chemiluminescence immunoassay as an inexpensive and sensitive alternative to radioimmunoassay for measuring SmC in serum or in extracts of serum.

DNA, Recombinant↗

Measurement of testosterone and its 5-alfa-reduced metabolites in human prostatic tissue using isotope dilution mass spectrometry.

5 alpha-Dihydrotestosterone (DHT) has been widely measured in human prostatic tissue using RIA since it is found to be involved in pathogenesis of human prostatic hyperplasia (BHP) and to be the best index for the follow-up of patients affected by prostatic cancer under endocrine treatment. A GC/MS method for the simultaneous determination of testosterone (T), dihydrotestosterone (DHT), 5 alpha-androstan-3 alpha,17 beta-diol (3 alpha-diol) and 5 alpha-androstan-3 beta-17 beta-diol (3 beta-diol) in prostatic tissue was developed based on the isotopic dilution technique. Trideuterated internal standards of each compound were previously synthesized in our laboratory. After previous extraction and purification on Sep-Pak C-18 cartridges and Lipidex DEAP columns, T and its metabolites were measured as heptafluorobutyric esters (HFB). Quantitative analysis was performed on a VG 7070 EQ mass spectrometer equipped with a fused silica capillary column using the Selected Ion Monitoring technique. Steroid values (means +/- SD; ng/g tissue) found in 9 human hypertrophic prostates were: T, 0.71 +/- 0.43; DHT, 4.46 +/- 1.41; 3 alpha-diol, 0.34 +/- 0.23; 3 beta-diol, 0.14 +/- 0.32.

Androstane-3,17-diol↗

Measurement of transferrin in human seminal plasma by a chemiluminescent method.

We describe a luminescence immunoassay for measuring transferrin in human seminal plasma. Human transferrin conjugated with 7-[(N-4-aminobutyl)-N-ethylamino]naphthalene-1,2-dicarboxylic acid hydrazide was used to monitor the immunological reaction. The conjugate was stable for at least one year. The sensitivity (2 ng per tube) of the assay allows measurement of this protein in diluted seminal plasma. Results by this method (y) correlated well (r = .9681) with those by a conventional RIA method (x): y = 1.000x + 1.646 micrograms per ejaculate. Seminal transferrin concentrations are reported for normal control subjects, vasectomized subjects, and infertile patients. The method described appears suitable for measurement of seminal transferrin as an index of Sertoli cell function in male infertility.

Humans↗

Pregnanediol-3 alpha-glucuronide measured in diluted urine by mass spectrometry with fast atom bombardment/negative-ion ionization.

We describe a mass-spectrometric method based on the fast atom bombardment ionization technique in the negative-ion mode for measuring pregnanediol-3 alpha-glucuronide in diluted urine from women. The procedure requires addition of testosterone-17 beta-D-glucuronide (2.5 micrograms/25 microL) to the urine sample as internal standard, and the sample is added directly to the fast atom bombardment target with no further manipulation. We have assessed and evaluated the method by the traditional criteria of reliability.

Adult↗

Homogeneous luminescence immunoassay for total estrogens in urine.

We describe an homogeneous luminescence immunoassay for "total" estrogens in enzymically hydrolyzed urine from nonpregnant women. The antiserum, raised against estriol-16,17- dihemisuccinate conjugated to bovine serum albumin, specifically bound the C-19 steroids carrying the estrogen-characteristic phenolic group. 17 beta-Estradiol conjugated with aminobutylethyl isoluminol was used to monitor the immunological reaction; this conjugate was stable for at least two years. Because binding to the antiserum markedly enhances the light-producing efficiency of the tracer, no separation of bound and free antigen is necessary. Results (microgram/24 h) by this method (y) correlated well (r = 0.958) with those by a conventional fluorometric (x) method (y = 2. 51x - 2.83). The sensitivity (detection limit) is 4 micrograms/L and the precision compares well with that of commonly used RIA methods. The method appears suited to large numbers of samples, as in menstrual cycle monitoring.

Cross Reactions↗

On-line computer analysis of chemiluminescent reactions, with application to a luminescent immunoassay for free cortisol in urine.

We interfaced a microcomputer on-line with a luminometer to acquire the light signal of chemiluminescent reactions from a photomultiplier and then compute significant parameters of light emission and kinetic "shape" indices. Using this system to study interferences from biological samples on the measurement of chemiluminescent reactions, we observed that such effects are usually associated with modifications of the shape of the light-emission kinetics. These results suggest that a simultaneous evaluation of the shape of a chemiluminescent reaction and the measurement of light emission can be combined to assess luminescent immunoassays as an internal control of the interferences in measurements of the chemiluminescent tracer. As an example of this approach, we developed and validated a luminescent immunoassay for free cortisol in diluted urine. Dextran-coated charcoal is used for bound-free separation.

Chemical Phenomena↗

A solid phase chemiluminescent immunoassay (LIA) for testosterone glicuronide in diluted urines.

A chemiluminescent immunoassay (LIA) method in solid phase for the measurement of testosterone 17 beta-D-glicuronide (TG) in diluted urine is described, which utilizes as tracer a TG-isoluminol conjugate (TG-ABEI). An IgG fraction of antiserum of TG-BSA, has been passively adsorbed to the walls of polystyrene tubes. After the binding reaction the coated tubes were washed with buffer and the measure of chemiluminescence reaction was performed at high pH. The assay was validated in terms of specificity, accuracy, sensitivity and precision. The values obtained by chemiluminescence immunoassay were compared with that obtained by the RIA method, and the two methods agreed well (r = 0.95, n = 28). The assay method offers the advantage of speed and does not involve the use of radioisotopes or of a centrifugation step. Preliminary results show that the mean 24 h urinary TG excretion in a group of hirsute women is higher than in the control group, and decreases after suppression with dexamethasone for 1 month of therapy.

Cushing Syndrome↗

Preparation and evaluation of steroid chemiluminescent tracers.

Six different isoluminol derivatives have been synthesized and evaluated as potential labels for conjugation to steroid molecules. The resulting steroid-chemiluminescent tracers have been investigated in terms of detection limit and affinity for the homologous antibody. The conjugation to the steroid molecule did not significantly affect the quantum yield of the chemiluminescent label. Consequently the detection limit was very similar using tracers with the same chemiluminescent label and different steroids and it was always at picomolar levels. The affinity of the chemiluminescent tracer versus the homologous antibody was evaluated using tritiated steroids as reference. The bridge and the chemiluminescent molecule could influence the affinity of the chemiluminescent tracer which could be higher, similar or lower than that of the tritiated steroid. In conclusion some isoluminol derivatives (i.e. ABEI or AEEI) can be considered as universal labelling compounds for steroids and their metabolites, because they possess a high light efficiency (similar to luminal itself) and favourable reaction conditions. Moreover the conjugation to the steroid molecule does not modify their chemiluminescent properties.

Animals↗

Evaluation of different progesterone-isoluminol conjugates for chemiluminescence immunoassay.

The effect of varying the length of the alkyl bridge linking the chemiluminescent label isoluminol to progesterone on the light yield and binding affinity of progesterone chemiluminescent-marker conjugates was investigated. For this purpose five different derivatives of isoluminol, aminoethyl isoluminol (AEI), aminoethylethyl isoluminol (AEEI), aminobutyl isoluminol (ABI), aminobutyl-ethyl isoluminol (ABEI) and aminoethyl-ethyl isoluminol (AHEI) were covalently linked through a peptide bond to progesterone-11 alpha -hemisuccinate (P-11-HS). The resulting progesterone chemiluminescent-marker conjugates were then evaluated as potential labels for the development of an immunoassay based on monitoring chemiluminescence. These conjugates were able to compete with tritiated progesterone for the binding sites of an antibody raised against progesterone-11 alpha-HS bovine serum albumin, and they showed higher affinity than unaltered progesterone. These conjugates produced light upon oxidation by a hydrogen peroxide-microperoxidase system. The chemiluminescent reaction was optimized in terms of pH, concentration of oxidant, catalyst and conjugate design. Under optimal conditions, all the conjugates were detectable at femtomolar levels. The lowest detection limit was obtained using P-11-HS-ABEI (0.1 fmol). These results indicated that immunoassay techniques based on chemiluminescence can be developed with these labels.

Animals↗

Luminescent immunoassay (LIA) for progesterone in a heterogeneous system.

An immunoassay procedure for determination of progesterone in human plasma is described which utilizes chemiluminescence as the endpoint. The assay utilized progesterone-11-hemisuccinate-aminobutyl-ethyl-isoluminol (P-11-HS-ABEI) as the chemiluminescent marker conjugate and dextran coated charcoal for the separation of bound and free fractions of the ligand. An assay procedure for progesterone was established and validated in terms of sensitivity and precision, and assay results were compared with radioimmunoassay, using tritiated progesterone as the tracer. The two methods agreed well (n=35, r=0.96). The most important advantage of this assay is the elimination of problems inherent in the use of radioactive materials.

Azides↗