PubMed HealthSearch

Biomedical subjects

M Piattelli

Publications and source records attributed to M Piattelli.

At least 19 recordsLinked to original sources

Leiomyosarcoma of the oral cavity: report of two cases located on the lips.

The authors report 2 cases of leiomyosarcoma of the lips occurring in two elderly women. They review the incidence, the symptoms, the microscopic appearance, the differential diagnosis, the treatment and prognosis of this kind of tumor. It is a highly malignant neoplasm with a high rate of recurrences and metastases and should be treated with a radical resection and radical neck dissection when there is a metastatic node.

Aged

[Condensation of gutta percha after McSpadden].

The Authors have studied the efficacy of the sealing effect of thermomechanical compaction of guttapercha according to McSpadden with an in vitro analysis on undecalcified tooth sections and with a clinical evaluation of ten patients with periapical lesions. The analysis of the results has shown a good sealing capacity of the McSpadden technique.

Dental Leakage

Benign cementoblastoma: review of the literature and report of a case at an unusual location.

Benign cementoblastoma is a rare odontogenic tumour localized in the jaws of young people. Benign cementoblastoma has characteristic radiologic and microscopic features and it appears to be fused to the tooth roots. The most important differential diagnosis is-with a benign osteoblastoma. The tumor should be enucleated and the teeth extracted. This case represents only the third reported case of a benign cementoblastoma associated with a third molar.

Diagnosis, Differential

[Ultrasonics in endodontics. Light microscope study].

The purpose of this study was to study the efficacy of an endodontic cleansing procedure to remove the pulp and the dentin from the root canal system with a new endodontic instrument proposed by J.M. Laurichesse, the Shaper.

Evaluation Studies as Topic

A new device for electrocoagulation of small vessels.

The importance of sealing small vessels by electrocoagulation in microsurgery is well known. In practice, the reliability of both short and long time results obtained with common and bipolar forceps with radiofrequency application is variable, particularly when encrusted coagulations adhere to the forceps tips and there is danger of damaging the vessel when the forceps are withdrawn. The coagulation process involves a sudden change in tissue characteristics, that occurs within a narrow temperature range, closely following the pattern of the applied current and is only modified by heat dissipation to the cooler parts, such as the forceps tips. Keeping these principles in mind, we developed an improved device which provides: A well-balanced current flow between the tips, which is unaffected by wiring, distributed capacitance and current leakage of the electrocoagulator ; a time-dependent heating pattern that coagulates only the core of the clamped tissue.

Electrocoagulation