PubMed Health⌕ Search

Biomedical subjects

M Podgor

Publications and source records attributed to M Podgor.

7 recordsLinked to original sources

Pilot trial of the safety, tolerability, and retinoid levels of N-(4-hydroxyphenyl) retinamide in combination with tamoxifen in patients at high risk for developing invasive breast cancer.

PURPOSE: N-(4-hydroxyphenyl) retinamide (¿4-HPR, Fenretinide; R.W. Johnson Pharmaceutical Research Institute, Springhouse, PA) and tamoxifen (TAM) have synergistic antitumor and chemopreventive activity against mammary cancer in preclinical studies. We performed a pilot study of this combination in women at high risk for developing breast cancer. PATIENTS AND METHODS: Thirty-two women were treated with four cycles of 4-HPR, 200 mg orally (PO) for 25 days of each 28-day cycle, and TAM, 20 mg PO once daily for 23 months beginning after 1 month of 4-HPR alone. Tolerability, dark adaptometry, tissue biopsies, and retinoid plasma concentrations (Cp) were evaluated. RESULTS: Symptomatic reversible nyctalopia developed in two patients (6%) on 4-HPR, but 16 (73%) of 22 patients had reversible changes in dark adaptation, which correlated with relative decrease in Cp retinol (P </=.01). Four patients stopped treatment for side effects, and 84% of patients had hot flashes. Other commonly reported (grade </= 2) reversible toxicities included skin and ocular dryness, fatigue, and mood changes. Serum high-density lipoprotein increased and cholesterol decreased from baseline to month 4. Baseline mean +/- SD Cp retinol was 708 +/- 280 ng/mL. Mean +/- SD Cp of 4-HPR, N-(4-methoxyphenyl) retinamide (4-MPR), and retinol after 1 month of 4-HPR were 0.34 +/- 0.21 micromol/L, 0.28 +/- 0.21 micromol/L, and 282 +/- 127 ng/mL, respectively. Mean retinoid Cps did not change after 3 months of 4-HPR + TAM. CONCLUSIONS: TAM administration did not affect Cp 4-HPR or 4-MPR. Reversible nyctalopia correlated with relative decrease in Cp retinol but was not symptomatic for most patients. TAM + 4-HPR has acceptable tolerability for this high-risk cohort.

Administration, Oral↗

Glutathione S-transferase M1 genotype and age-related cataracts. Lack of association in an Italian population.

PURPOSE: To investigate possible associations between the gene number and allelic forms of glutathione S-transferase M1 (GSTM1) and the occurrence of nucleic and cortical age-related cataracts. METHODS: Patients with cortical cataract, nuclear cataract, mixed and cortical cataract, and no cataract were sytematically selected from subjects evaluated in the Italian-American Study of the Natural History of Age-Related Cataract. The patients were typed for the A, B, and null alleles of GSTM1 using a variation of the amplification refractory mutation system. RESULTS: Forty-nine percent of patients (50/102) with cortical cataracts, 45% (13/29) with nuclear cataracts, 51% (36/71) with mixed nuclear and cortical cataracts, and 50% of controls (49/98) were homozygous for the null GSTM1 allele. Twenty-five percent of patients (26/102) with cortical cataracts, 24% (7/29) with nuclear cataracts, 31% with mixed nuclear and cortical cataracts, and 27% of controls (26/98) displayed only the A allele for GSTM1. Twenty-four percent of patients (24/102) with cortical cataract, 24% (7/29) with nuclear cataracts, 14% (10/71) with mixed nuclear and cortical cataract, and 18% of controls showed only the B allele for GSTM1. Two percent of patients (2/102) with cortical cataracts, 7% (2/29) with nuclear cataracts, 4% (3/71) with mixed nuclear and cortical cataracts, and 5% of controls (5/98) showed both A and B alleles for GSTM1. CONCLUSIONS: No associations between the GSTM1 alleles, including the null allele, and cataracts were detected in this study.

Aged↗

Reproducibility of the Early Cataract Detector (Kowa ECD 2000).

We conducted a reproducibility study on the Kowa Early Cataract Detector, a laser light scattering spectroscope that determines the diameter of particles within the lens and designed to quantify changes in particle size in early cataracts. We found good reproducibility in the nuclear region (where changes are homogeneous), but found poor reproducibility in the cortical region (where changes are heterogeneous). We advise careful evaluation of other similar devices before extensive use.

Cataract↗

A comparative study between the PAM and the laser interferometer in cataracts.

We conducted a prospective study on 35 consecutive eyes undergoing cataract extraction to compare the Guyton-Minkowski Potential Acuity Meter (PAM) and the Laser Interferometer (LI) in determining potential visual acuity. The eyes were divided into: group A, which had good visualization of optic disc details, and group B, whose media allowed only disc outline or less to be seen. We found that in group A eyes, both instruments were reliable (with accuracies of 94% for the PAM and 88% for the LI). However, in group B eyes (advanced cataracts), both instruments were unreliable (accuracies of 33% for the PAM and 53% for the LI). Interestingly, in a subgroup of high myopes (axial length greater than 29 mm) with moderate cataracts and poor visual acuties, both instruments were very reliable and helpful in determining how much of the vision loss was due to the cataracts. We therefore strongly recommend potential acuity testing in high myopes with moderate cataracts and poor visual acuity.

Aged↗