PubMed Health⌕ Search

Biomedical subjects

M Puc

Publications and source records attributed to M Puc.

2 recordsLinked to original sources

Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses. Part I. Increased efficiency of permeabilization.

The paper presents a comparative study of electropermeabilization of cells in suspension by unipolar and symmetrical bipolar rectangular electric pulses. While the parameters of electropermeabilization by unipolar pulses have been investigated extensively both in cell suspensions and in tissues, studies using bipolar pulses have been rare, partly due to the lack of commercially available bipolar pulse generators with pulse parameters suitable for electropermeabilization. We have developed a high-frequency amplifier and coupled it to a function generator to deliver high-voltage pulses of programmable shapes. With symmetrical bipolar pulses, the pulse amplitude required for the permeabilization of 50% of the cells was found to be approximately 20% lower than with unipolar pulses, while no statistically significant difference was detected between the pulse amplitudes causing the death of 50% of the cells. Bipolar pulses also led to more than 20% increase in the uptake of lucifer yellow. We show that these results have a theoretical background, because bipolar pulses (i) counterbalance the asymmetry of the permeabilized areas at the poles of the cell which is introduced by the resting transmembrane voltage, and (ii) increase the odds of permeabilization of cells having a nonspherical shape or a nonhomogeneous membrane. If similar results are also obtained in tissues, bipolar pulse generators could in due course gain a wide, or even a predominant use in cell membrane electropermeabilization.

Animals↗

Comparative analysis of pollen counts of Corylus, Alnus and Betula in Szczecin, Warsaw and Lublin (2000-2001).

The aim of the study was to compare the airborne concentrations of allergenic pollen produced by three early flowering tree taxa (Corylus, Alnus, Betula) in the cities of Warsaw (central Poland), Lublin (eastern Poland) and Szczecin (western Poland) during the years 2000-2001. Measurements were performed by the volumetric method. Pollen seasons were defined as the periods in which 95% of the total catch occurred. The highest concentration and annual pollen count of Corylus was measured in Lublin in both seasons, while the highest annual pollen counts of Alnus and Betula were noted in Warsaw, where the annual pollen count of Betula in 2001 was four times higher than in 2000 and equalled 5,376 grains in m3 per 24 h. Significant differences in the pollen count of the examined taxa were observed between two seasons: the pollen count of Corylus was higher in 2000 than in 2001, while for Alnus and Betula the opposite was the case. The longest pollen seasons were observed at low annual pollen counts for the pollen of Corylus. Results of the study reveal significant differences between the seasons and the cities. The differences concern the dates of the appearance of pollen grains in the air, the duration of the presence of sporomorphs and the maximum concentrations in particular seasons. The pollen counts of alder, birch and hazel trees are determined by the weather, diversity of local flora and specific rhythm of pollination of particular taxa.

Air Pollution↗