PubMed Health⌕ Search

Biomedical subjects

M Puech

Publications and source records attributed to M Puech.

At least 19 recordsLinked to original sources

The seroepidemiology of pertussis in Australia during an epidemic period.

Studying the epidemiology of pertussis and impact of differing vaccine schedules is difficult because of differing methods of case ascertainment. The advent of internationally standardized serological diagnosis for recent infection has allowed comparison of age-specific pertussis infection among European countries and was applied in Australia at the time of a major national epidemic. In 1997 and 1998, a nationally representative serum bank using residual sera from diagnostic laboratories was established. Measurement of pertussis toxin (PT) IgG level was conducted by a reference laboratory using an enzyme-linked immunosorbent assay standardized for a number of European countries. A titre of 125 EU/ml was interpreted as indicative of recent pertussis infection. The serological data were correlated with age, gender, region and disease epidemiology in Australia. The highest prevalence of recent pertussis infection was in the 5-9 years age group, and the lowest in 1-4 and 25-64 years age groups. In the 5-14 years age group, 29.7% (5-9 years) and 14.6% (10-14 years) of the sample had serological evidence of recent infection, correlating with the pattern of epidemic notifications. The 15- to 24-year-olds had similar high titres but the same notification rate as 25- to 44-year-olds, suggesting ascertainment bias may result in under-notification in the former age group. The prevalence of high titres observed was up to 20-fold higher than some European countries during a similar time period. Although vaccination has reduced the transmission of pertussis in the youngest and most vulnerable age group, pertussis is still endemic in Australia, particularly in older children and the elderly. The Australian vaccination schedule has been changed in an attempt to address this problem, by spacing doses more widely, with the fifth dose at 15-17 years of age. Seroepidemiology for pertussis offers the potential to compare patterns of pertussis between countries and examine the impact of vaccine schedule changes independent of notification and diagnostic bias.

Adolescent↗

[OCT3 exploration of anterior segment].

PURPOSE: Posterior pole imaging with OCT3 provides macular scans with a very high resolution. Use of OCT1 has already been described for anterior segment imaging. This work presents the advantages of OCT3 in anterior segment imaging compared to UBM (50 MHz) and 20-MHz ultrasound imaging with long focal distance (patent pending PCT/FR98/02788). MATERIAL: and methods: We used an OCT3 unit dedicated to the posterior pole. By defocusing the laser beam we obtained high-resolution scans of the cornea, angle, lens and IOLs. Fifty-seven eyes (35 patients) were imaged by OCT3 and high-resolution ultrasound in cases of corneal dystrophy, corneal transplant, LASIK, narrow angle, iris bowing, etc. RESULTS: In all cases OCT3 provided high-resolution information with a limit of penetration at the posterior part of the iris. This limitation was not observed with ultrasound imaging. Nevertheless, OCT3 is a useful tool for corneal imaging in cases of opacities limiting biomicroscope imaging. OCT3 corneal scans at high resolution make it possible to identify the corneal interface in lamellar transplants or LASIK. With a narrow angle, a dynamic test of angle closure can be done. With iris bowing, OCT3 can differentiate iris cysts and iris tumors. Anterior chamber IOLs can be imaged with their relationships to anterior segment structures. CONCLUSION: OCT3 provides non-contact anterior segment imaging with high resolution but with a limit of penetration given by posterior part of the iris.

Anterior Eye Segment↗

[The Voice Handicap Index: impact of the translation in French on the validation].

The aim of this prospective investigation was to validate a French version of the Voice Handicap Index (VHI). A population of 52 normal subjects and 63 patients with voice disorders replied to the questionnaire at the day of their first consultation and ten to thirty days after the consultation (before any treatment). Reproducing the methodology of the American authors, the test-retest reliability and the internal consistency reliability were measured. The validity and the sensibility related to a non dysphonic population were also analysed. Regarding the normal subjects, the maximum scores for total score and subscale scores were 20 (total), 12 (physical), 7 (functional), 6 (Emotional). These scores are statistically different when compared with pathological subjects (p < 0.00001). Test-Retest stability of the pathological subjects was found to be satisfactory for both total score and subscale scores (r > 0.87). From this data set, the critical difference scores were derived for the VHI total score (15 points), for the physical subscale (9 points) and for the functional and emotional.subscales (6 points each). As for as the internal consistency reliability, Cronbach's alpha is correct (r > 7) for the pathological subjects. Yet, the analysis of the validity reply by reply, reveals some abnormalities. In conclusion, the validity of the French translation of the VHI is confirmed but the results prompt us to improve the quality of the translation.

Adult↗

[Voice after supracricoid partial laryngectomy: comparison of two phonatory mechanisms].

INTRODUCTION: Different laryngeal phonatory mechanisms may be observed at long term after supracricoid laryngectomy. For this study two mechanisms are differentiated. The "dilated" mechanism is the consequence of a forward movement of the neolarynx creating a new resonance cavity. The "contracted" mechanism tallies with the backward contraction of the base of the tongue and the contraction of the posterior pharyngeal wall compressing the neolarynx. OBJECTIVE: The aim of the study is to determine if the voice outcome is different between these two kinds of mechanisms. MATERIAL AND METHOD: The method is based on the selection of a homogeneous group: 12 patients operated by cricoepiglottopexy with a follow up superior to two years and with a stable voice and a full neoglottic closure during phonation. The voice quality and the phonatory mechanism are analysed. Regarding voice assessment, a self evaluation with the vocal handicap index adapted for the study and the GRBAS scale are carried-out. Frequency (usual, minimum, maximum, range) and loudness are used to appreciate the vocal capacities. The phonatory mechanism is studied by videolaryngostroboscopy, performed tongue free, with a normal /e/ and a high-low transition pitch. RESULTS: The outcomes point out a difference between the two mechanisms. The best vocal results are observed in the "dilated" mechanism for the studied parameters and mainly for the frequency parameters. CONCLUSION: The discovery of numerous phonatory mechanisms after supracricoid laryngectomy independent from neoglottic closure lead us to further studies of the impact of this type of surgery on articulatory patterns.

Aged↗

Fresh garlic: a possible vehicle for Salmonella Virchow.

A sustained increase in Salmonella enterica serovar Virchow notifications in South Eastern Australia between September 1997 and May 1998 instigated a case-control study and environmental investigations. Cases were defined as having locally acquired culture-confirmed S. Virchow phage-type 8 infection and diarrhoeal disease. Matched controls were selected by progressive digit dialling based on cases' telephone numbers. An exposure and food history questionnaire was administered by telephone. Phage typing and pulse field gel electrophoresis were performed on case and environmental isolates. Thirty-two notifications of S. Virchow infection met the case definition, 37% reported bloody diarrhoea and S. Virchow was isolated from blood in 13% of cases. Twelve patients were admitted to hospital and one died. Fresh garlic (OR 4.1, 95% CI 1.3-12.8) and semi-dried tomatoes (OR 12.6, 95% CI 1.5-103.1) were associated with these cases. The associations remained significant after adjusting for sex and age. S. Virchow (PT 8) was cultured from two brands of semi-dried tomatoes associated with cases in two different states. We provide sufficient evidence for semi-dried tomatoes and fresh garlic to be considered as potential risk foods in future Salmonella outbreak investigations.

Adolescent↗

Fatal acute poisoning by bentazon.

A case of fatal suicidal bentazon poisoning is presented along with a description of the different analytical methods involved. A 56-year-old farmer was examined by the family doctor 1 h after voluntarily ingesting 500 mL of FIGHTER (bentazon, 480 g/L water). He presented a Glasgow score of 15, polypnea, diarrhea, and vomiting. During transport by ambulance to the hospital, he tossed, sweated, and suddenly presented breathing difficulty followed by heart failure. Tracheal intubation was impossible (H1.5) despite use of different diameter cannulas because of extreme general muscle rigidity. All attempts at resuscitation failed, and the patient died within 2 h postingestion. Blood and urine samples were taken just before death. General basic and neutral drug screening by high-performance liquid chromatography-diode-array detection and gas chromatography-nitrogen-phosphorus detection showed no strychnine or other drugs or toxics except for citalopram (< 0.1 mg/L) and bentazon, but this weak acidic molecule (pKa3.3) was badly extracted in alkaline conditions. Plasma and urine levels, measured after acidic extraction, protein precipitation, or simple dilution, were 1500 and 1000 mg/L, respectively. Bentazon (M.W. 240) was confirmed by its basic mass spectrum (ESI-, m/z 239, 197, 175, 132) or by that of methylated derivative (El+, m/z 254, 212, 175). An hydroxylated metabolite (ESI-, m/z 255, 213, 191, 148; El+, m/z 284, 242, 163) and the N1-glucuronide conjugate of bentazon (ESI-, m/z 415, 239) were also detected in urine. (Quantitation ions are underlined.) This first case of bentazon poisoning with available analytical data revealed the high toxicity of this compound after large dose ingestion with early and heavy symptoms such as muscle rigidity probably related to muscular toxicity. Comparison with another nonfatal case and with toxicological data on animals is discussed.

Benzothiadiazines↗

[Difficult cases in biometry measurement].

A few problems have not yet been resolved concerning intraocular lens (IOL) power calculation in difficult cases. Patients can be divided into three groups: Group 1, patients with no previous ocular surgery but with unusual anatomy (staphyloma, high hyperopic eyes, etc.); Group 2, patients with previous surgery except refractive surgery; Group 3, patients with previous refractive surgery. Various techniques must be used to increase the accuracy of IOL calculation. B-mode biometry and optical coherence tomography are suitable tools to increase the accuracy of axial length measurement. Computerized videokeratography can be helpful. However, the most difficult cases seem to be those in Group 3.

Biometry↗

[Glaucoma and high-frequency ultrasound].

The iridocorneal angle and the ciliary body are imaged with high precision using high-frequency ultrasound. A long-focus 20-MHz probe provides high-resolution imaging of the optic disk and optic nerve. These improvements mean that glaucomatous patients can be imaged by ultrasound with increased precision.

Glaucoma↗

[Orbscan: a new device for iridocorneal angle measurement].

PURPOSE: To evaluate the accuracy and reproducibility of iridocorneal angle measurement obtained with a slit-lamp method (Orbscan). METHODS: The iridocorneal angle was measured in 100 normal eyes of 50 patients using the Orbscan II device. Angles were measured in eight meridians using both the "plane" and "polynomial" modes. For each eye, two exams were taken successively and the reproducibility was calculated by analyzing the difference between both measurements. Angle value was correlated with subjective spherical equivalent and other biometric measurements obtained by Orbscan (i.e., anterior chamber depth, axial length, corneal diameter). RESULTS: Reproducibility of the angle measurement was significantly better with the plane mode than with the polynomial mode (5.4%+/-4.7 versus 7.2%+/-6.2; p<0.001). Reproducibility significantly varied with localization (p<0.001). Significant differences were found between reconstruction modes (49.3 degrees +/-4.6 degrees for plane mode versus 42.8 degrees +/-6.7 degrees for the polynomial mode; p<0.001) and according to localization (p=0.02). Correlation with the other biometric measurements was higher for the plane mode than for the polynomial mode. Angle measurement with the plane mode showed significant correlation with subjective spherical equivalent (r(s)=-0.59; p<0.001), the anterior chamber depth measurement (r(s)=-0.74; p<0.001), the axial length measurement (r(s)=-0.34; p<0.002), and the corneal diameter measurement (r(s)=-0.34; p<0.002). CONCLUSION: The iridocorneal angle measure obtained with the plane mode showed high reproducibility and it significantly correlated with clinical parameters. It appears to be useful for clinical application.

Adolescent↗

[Ocular biometric measurements with a slit-lamp method (Orbscan)].

PURPOSE: To evaluate the accuracy and reproducibility of the biometric measurements obtained with the Orbscan((R)) device in normal eyes. METHODS: Anterior chamber depth, axial length, and corneal diameter were studied in 50 normal eyes of 25 patients using the Orbscan((R)) device and A-Scan ultrasonography. For each eye, two exams were done successively and reproducibility was calculated by analyzing the difference between both measurements. RESULTS: The reproducibility of anterior chamber depth and corneal diameter measurements obtained by Orbscan((R)) was high (respectively 0.721.25% and 0.831.40%). The anterior chamber depth measurements by Orbscan((R)) and A-Scan ultrasonography were strongly correlated (rs=0.92;p<0.001). The axial length measurement obtained with the Orbscan((R)) device was less reproducible (3.554.11%). For the axial length, the Orbscan((R)) measurements and A-Scan ultrasonography measurement was poorly correlated. (rs=0.64; p<0.001). CONCLUSION: The anterior chamber depth measurement obtained with the Orbscan((R)) device showed high reproducibility and it was strongly correlated with the measurement obtained by A-Scan ultrasonography. Axial length measurement obtained with the Orbscan((R)) device was less reproducible and poorly correlated with the A-Scan ultrasonography measurement. It was not relevant for clinical application.

Adult↗

[Cataract surgery after refractive surgery. Part I: practical surgical consequences].

Prior refractive surgery has little incidence on the phako-exeresis technique. Most of the precautions taken are based more on theoretical considerations rather than extensive clinical experience. Excepting cases of high myopy corrected with IOL where early opacification may have occurred, mo st of the population undergoing refractive surgery has not yet reached the age of cataracts. In case of prior corneal surgery (radial keratotomy, PKR, Lasik or intracorneal ring segments) the incision tunnel must remain behind or away from the anatomically modified sectors. In case of prior refractory surgery, explantation must always precede the procedure. A large diameter (6mm or more) lens is always chosen in order to ava avoid optical consequences of modifications induced by the aspheric cornea.

Cataract Extraction↗

[Cataract surgery after refractive surgery: Part II: the problem of implant calculation].

Refractive surgery is a growing technique in a selected population of young patients who no longer want to wear corrective lenses. As this population becomes older and reaches an age where cataracts may develop, we decided to examine the problems encountered in calculating the IOL. Certain techniques may perturb keratometry oe measurement of axis length, two elements essential for calculating the implant. In certain cases where no solution is currently available for making these measurements, we propose archiving keratometry and axial length measurements for candidates for refractive surgery.

Aged↗

Standardisation of DNA quantitation by image analysis: quality control of instrumentation.

BACKGROUND: DNA image analysis is frequently performed in clinical practice as a prognostic tool and to improve diagnosis. The precision of prognosis and diagnosis depends on the accuracy of analysis and particularly on the quality of image analysis systems. It has been reported that image analysis systems used for DNA quantification differ widely in their characteristics (Thunissen et al.: Cytometry 27: 21-25, 1997). This induces inter-laboratory variations when the same sample is analysed in different laboratories. In microscopic image analysis, the principal instrumentation errors arise from the optical and electronic parts of systems. They bring about problems of instability, non-linearity, and shading and glare phenomena. METHODS: The aim of this study is to establish tools and standardised quality control procedures for microscopic image analysis systems. Specific reference standard slides have been developed to control instability, non-linearity, shading and glare phenomena and segmentation efficiency. RESULTS: Some systems have been controlled with these tools and these quality control procedures. Interpretation criteria and accuracy limits of these quality control procedures are proposed according to the conclusions of a European project called PRESS project (Prototype Reference Standard Slide). Beyond these limits, tested image analysis systems are not qualified to realise precise DNA analysis. CONCLUSIONS: The different procedures presented in this work determine if an image analysis system is qualified to deliver sufficiently precise DNA measurements for cancer case analysis. If the controlled systems are beyond the defined limits, some recommendations are given to find a solution to the problem.

DNA, Neoplasm↗

Choroidal neovascularization as a late complication of hyperparathyroidism.

PURPOSE: To report choroidal neovascularization in a patient with sclerochoroidal calcification secondary to hyperparathyroidism. METHOD: Case report. Bilateral ocular fundus abnormalities observed in a 74-year-old woman were documented with fluorescein angiography and ultrasonography. RESULTS: Two yellow, irregular, oval placoid lesions were observed in the fundus of each eye. Ultrasound examination showed that these areas were extremely sonoreflective and exhibited orbital shadowing. In the left eye, one lesion was accompanied by lipid exudates, and subsequent fluorescein angiography disclosed choroidal neovascularization. Medical history included hyperparathyroidism treated with surgical excision of a parathyroid adenoma 27 years earlier. CONCLUSION: Choroidal neovascularization may be a late complication of hyperparathyroidism.

Aged↗

B-mode-guided vector-A-mode versus A-mode biometry to determine axial length and intraocular lens power.

PURPOSE: To compare prospectively the reproducibility and accuracy of B-mode-guided biometry with those of A-scan biometry using a conventional A-mode probe to calculate intraocular lens (IOL) power. SETTING: Department of Ophthalmology, Hôtel-Dieu de Paris, France. METHODS: The axial length (AL) in 87 eyes of 72 candidates for cataract surgery was determined by B-mode-guided vector-A-mode and A-mode biometry using an Ophthascan S Ultrasound imager. Patients were assigned to one of two groups based on the B-mode biometry: nonmyopic (AL < 24.5 mm; n = 54) or myopic (AL > 24.5 mm; n = 33). Postoperative refractive results were compared with attempted values. RESULTS: Mean AL variance was significantly greater when using the A-mode than the B-mode: 0.157 mm +/- 0.260 (SD) versus 0.015 +/- 0.018 mm in the myopic group (P < .001) and 0.024 +/- 0.024 +/- 0.045 versus 0.009 +/- 0.011 mm in the nonmyopic group (P < .001). More eyes having B-mode biometry achieved a final refraction within +/- 0.50 diopter (D) of the attempted refraction (63 and 43%, respectively; P < .05). No deviation greater than 1.60 D was observed with the B-mode in the myopic or nonmyopic group. Three cases with a such a deviation (up to 2.24 D) would have been observed had A-mode-based biometry been chosen for the IOL power calculation. In the myopic group, attempted postoperative refraction was within +/- 0.50 D in 78% of eyes having B-mode biometry compared with 65% having A-mode. This difference was not statistically significant. CONCLUSION> These results suggest that the reproducibility and accuracy of AL measurements are significantly better with B-mode-guided A-mode biometry than with A-mode biometry in myopic and nonmyopic eyes.

Biometry↗

Local implementation of national guidelines on lower urinary tract symptoms: what do general practitioners in Sydney, Australia suggest will work?

OBJECTIVES: Systematic reviews demonstrate that local initiatives are vital to implement nationally developed clinical practice guidelines. Evidence-based guidelines on the management of lower urinary tract symptoms in men were launched by the National Health and Medical Research Council in Sydney in April 1997. A study was conducted through interviews to establish patterns of care in the catchment area before the guidelines were implemented and general practitioners were surveyed in order to ascertain the most useful strategies for local implementation. DESIGN: A four-page questionnaire asked respondents to rate nine items about guideline dissemination; six items relating to the marketing of the guidelines and 15 implementation strategics: conventional educational activities (six); innovative educational strategies (four); quality improvement approaches (two) and patient-based approaches (three). SETTING: Sydney, Australia. STUDY PARTICIPANTS: Eighty-three randomly selected general practitioners (50 males; 33 females). RESULTS: Eighty-three out of 108 surveys were returned (77%). Respondents placed high value upon endorsement by eminent individuals and organizations other than the organization developing the guidelines; this was likely to gain their initial attention. One hundred per cent of respondents would be encouraged to use the guidelines if they were promoted as improving quality of care. Implementation strategies preferred by respondents included small group continuing education with a urologist and a general practitioner as a facilitator, lectures and patient education materials. Internet access, interactive computer systems, academic detailing' and distance education modules were of least interest. CONCLUSIONS: Our method is feasible as a first step in planning local dissemination and implementation for national guidelines. While useful in identifying preferred strategies, its longer-term predictive validity for improving patient outcomes through better guideline implementation needs to be established.

Adult↗