PubMed Health⌕ Search

Biomedical subjects

M R Back

Publications and source records attributed to M R Back.

33 records · Page 2Linked to original sources

Intraoperative prebypass arteriography for infrageniculate revascularization.

BACKGROUND: Selection of the optimal distal target for infrageniculate arterial revascularization remains difficult in patients with multilevel occlusive disease due to poor visualization of the distal vasculature by preoperative arteriography. Prebypass, intraoperative arteriography (IOA) with direct injection of contrast into the infrageniculate arteries may improve distal arterial visualization and bypass target selection. METHODS: One hundred fourteen extremities in 104 consecutive patients requiring infrageniculate bypass were prospectively studied. All patients underwent preoperative contrast arteriography (CA) of the aortoiliac and lower extremity arteries using iodinated and/or CO2 contrast and digital subtraction techniques. IOAs were obtained at operation to confirm the adequacy of the distal runoff from the predicted bypass target and to identify potentially superior targets. The preoperative plan formulated from the CA was compared to the actual procedure performed based on the IOA. The CA and IOA were also independently reviewed postoperatively by two blinded vascular surgeons to determine the number of patent vessel segments visualized and the number of segments with <50% stenosis. RESULTS: Revascularization was done in 105 of 114 extremities (92%), whereas amputation was required as the initial procedure in 9 patients (8%). The IOA altered the operative plan based on the CA in 27 of 144 patients (24%). Changes in the planned bypass procedures included selection of a more distal anastomotic site in 13 of 102 patients (13%), selection of a more proximal anastomotic site in 4 of 102 (4%), selection of a different artery for the distal anastomosis in 3 of 102 (3%), and amputation rather than bypass in 2 of 102 patients (2%) with no suitable distal bypass target on the IOA. The IOA also resulted in bypass rather than planned amputation in 5 of 12 patients (42%) deemed unreconstructable on the preoperative CA. A mean of 13 minutes was required for IOA and an adequate study was obtained on the first attempt in 98 of 144 patients (86%). On postoperative review, more patent vessel segments but fewer segments with <50% stenosis were identified on the IOA compared to the CA. CONCLUSIONS: Prebypass intraoperative arteriography facilitates selection of the optimal distal bypass target during infrageniculate revascularization and can result in initial limb salvage in select patients deemed unreconstructable by preoperative contrast arteriography.

Aged↗

Utility of magnetic resonance arteriography for distal lower extremity revascularization.

PURPOSE: Magnetic resonance arteriography (MRA) of the lower extremities affords several possible advantages over conventional contrast arteriography (CA). We hypothesized that MRA of the infrageniculate vessels was sufficiently accurate to replace CA before revascularization procedures in patients with limb-threatening ischemia. METHODS: Fifty-three extremities in 49 patients were prospectively evaluated before attempted infrageniculate revascularization procedures with preoperative infrageniculate time-of-flight MRA (cost, $170/study) and standard contrast arteriography (cost, $1310/study) of the aortoiliac and runoff vessels. Independent operative plans were formulated based on the MRA and CA results before the revascularization procedure. Intraoperative, prebypass arteriograms (IOA; cost, $46/study) were obtained in all patients to confirm the adequacy of the distal runoff. The preoperative plans formulated by the results of MRA and CA were compared with the actual procedure performed based on the IOA. All arteriograms (CA, MRA, IOA) were reviewed after the operation by two independent reviewers, and the number of patent vessel segments and those with < 50% stenosis was determined. RESULTS: Revascularization procedures were performed in 44 of 53 extremities (83%), and amputation was performed in nine extremities (17%) because of an absence of a suitable bypass target. The CA and MRA were equally effective in predicting the optimal operative plans as determined from IOA (CA, 42 of 53 [77%] vs MRA, 40 of 53 [75%]; p = 0.79). More patent vessel segments were seen on CA than MRA (reviewer A, 229 vs 174, kappa = 0.32; reviewer B, 321 vs 314, kappa = 0.46); however, a comparable number of segments were seen if the vessels of the foot were excluded. The accuracy (reviewer A, 78% vs 68%, p = 0.003; reviewer B, 75% vs 67%, p = 0.003) and sensitivity (reviewer A, 69% vs 51%, p = 0.001; reviewer B, 68% vs 46%, p = 0.0001) of CA relative to IOA were superior to those of MRA, although the specificity was comparable (reviewer A, 86% vs 90%, p = 0.31; reviewer B, 82% vs 87%, p = 0.52). The combination of MRA and IOA would have resulted in the optimal operative plan in 51 of the 53 cases (96%) and was comparable with CA and IOA (53 of 53; 100%; p = 0.50). Substitution of MRA and IOA for CA and IOA could potentially have saved an estimated $60,420. CONCLUSIONS: The combination of MRA and IOA provides an accurate, cost-efficient strategy for visualization of the infrageniculate vessels before revascularization procedures.

Aged↗

Improving the cost-effectiveness of carotid endarterectomy.

PURPOSE: Carotid endarterectomy (CEA) has been shown to significantly reduce the risk of stroke caused by carotid artery stenosis. Limiting the costs of CEA without increasing the risks will improve the cost-effectiveness of this procedure. METHODS: Results were prospectively collected from 63 consecutive CEAs performed in 60 patients who were entered into a clinical pathway for CEA that included avoidance of cerebral arteriography, preferential use of regional anesthesia, selective use of the intensive care unit (ICU), and early hospital discharge. The mortality rate, complications, hospital costs, and net income in these patients were then compared with results from 45 CEAs performed in 42 consecutive patients immediately before beginning the CEA pathway. Age, comorbid risk factors, incidence of symptoms, and degree of carotid artery stenosis were similar in both patient groups. RESULTS: The rates of mortality and complications associated with CEA were low (mortality rate, 0%; stroke, 0.9%; transient ischemic attack, 2.8%) and did not vary between the two groups. Implementation of the CEA pathway resulted in significant (p < 0.001) reductions in the use of arteriography (74% to 13%), general anesthesia (100% to 24%), ICU use (98% to 30%), and mean hospital length of stay (5.8 days to 2.0 days). These changes resulted in a 41% reduction in mean total hospital cost ($9652 to $5699) and a 124% increase in mean net hospital income ($1804 to $4039) per CEA (p < 0.01). For the 39 patients (62%) who achieved all elements of the CEA pathway, the mean hospital length of stay was 1.3 days, the mean hospital cost was $4175, and the mean hospital income was $4327. CONCLUSIONS: Costs associated with CEA can be reduced substantially without increased risk. This makes CEA an extremely cost-effective treatment of carotid disease against which new therapeutic approaches must be measured.

Aged↗

Detection and evaluation of aerodigestive tract injuries caused by cervical and transmediastinal gunshot wounds.

BACKGROUND: Aerodigestive tract penetrations occurring with gunshot wounds to the neck and thorax are uncommon but are frequently associated with multiple organ injury and contribute to significant morbidity. METHODS: The selective management strategy used at our institution for suspected aerodigestive tract involvement with cervical, thoracic inlet, and transmediastinal gunshot wounds is reviewed with reference to eight clinical cases from 1989 to 1995. RESULTS: Seven pharyngoesophageal and four laryngotracheal injuries are described with three patients sustaining combined aerodigestive organ wounds. Associated injuries occurred in seven of the eight cases. Diagnosis of aerodigestive tract penetrations were made by triple endoscopy in five patients, by contrast esophagography in one case, and at operation for associated injuries in two patients. No injuries were missed during endoscopy or contrast studies. Two patients suffered complications including delayed recognition of an esophageal injury and pneumonia in one case and dehiscence of a distal esophageal repair in another. An associated vascular injury resulted in a single death in the series. CONCLUSIONS: A high index of suspicion must be maintained for aerodigestive tract involvement with cervicothoracic gunshot wounds. We advocate operative endoscopic inspection during emergent exploration in unstable patients or arteriography with endoscopy in stable patients. Adjunctive contrast pharyngoesophagography is performed to confirm equivocal endoscopic findings, evaluate the extent of leak, or completely exclude injury.

Adolescent↗

Hemodynamic consequences of stenosis remodeling during coronary angioplasty.

Quantitative hemodynamic assessment during various endovascular interventions including balloon angioplasty is lacking. Translesional pressure drops measured by angioplasty catheters can cause flow blockage and thus lead to inaccurate estimates of preintervention and postintervention flow rates. A new analytical model of the flow rate-pressure drop relation across vascular stenoses is utilized that is nonlinear yet relatively simple in principle, easily applicable in vivo, and compatible with the presence of catheters. The model incorporates in vitro experimental evidence, angiographic data on the dimensions and shapes of coronary arterial stenoses before and after balloon angioplasty, reported translesional pressure gradients, and measurements of coronary flow reserve. Reasonable estimates of mean coronary artery flow rates and translesional pressure drops in the absence of angioplasty catheters are obtained. Prior to angioplasty significant flow restriction across a 68% diameter stenosis exists during hyperemic flow conditions. Following successful balloon dilation, increased minimal cross-sectional area (residual 40% diameter stenosis) results in an improved flow rate-pressure drop relation. Despite minimal flow restriction during hyperemic conditions following angioplasty remodeling, residual luminal constriction leads to elevated wall shear stress levels within the entry region of the stenosis. The flow analysis described may be of clinical utility in evaluating the hemodynamic significance of the anatomic severity of stenoses in coronary and peripheral arteries before and after endovascular therapeutic interventions.

Angioplasty, Balloon, Coronary↗

Flow rate-pressure drop relation in coronary angioplasty: catheter obstruction effect.

Quantitative methods to measure the hemodynamic consequences of various endovascular interventions including balloon angioplasty are limited. Catheters measuring translesional pressure drops during balloon angioplasty procedures can cause flow blockage and thus inaccurate estimates of pre- and post-intervention flow rates. The purpose of this investigation was to examine the influence of the presence and size of an angioplasty catheter on measured mean pressure gradients across human coronary artery stenoses. Analytical flow modeling and in vitro experimental evidence, coupled with angiographic data on the dimensions and shape of stenotic vessel segments before and after angioplasty, indicated significant flow blockage effects with the catheter present.

Angioplasty, Balloon, Coronary↗

Deposition pattern of monocytes and fatty streak development in hypercholesterolemic rabbits.

To further characterize the role of monocytes in atherogenesis, we studied the influence of a qualitatively, well-defined hemodynamic flow field on the deposition pattern of monocytes in the thoracic aorta of normal (N, n = 6) and hypercholesterolemic (H, n = 10) rabbits. Pairs of H rabbits were sacrificed after 1, 2, 4, 7 and 10 weeks of cholesterol feeding. Complete deposition patterns of adherent cells were quantified over 500 mm2 of aortic endothelium around the lesion-susceptible intercostal orifices using an en face light microscopic technique. Adherent cells were almost exclusively monocytes by morphological criteria and non-specific esterase staining. The mean density of adherent cells in normal rabbits was 1.28 +/- 1.21 (S.D.) per mm2 of endothelium and increased nearly 5-fold by 7 weeks of cholesterol feeding. High local densities of adherent monocytes (up to 34 cells/mm2) were noted over early fatty lesions present in one 4 week and all 7 and 10 week H rabbits. Adherent cell densities near intercostal orifices prior to lesion formation were approximately 50% greater than in non-orifice regions in both the normal and the 1 and 2 week H rabbit groups. These differences were statistically significant at P < 0.05 by ANOVA. We conclude that preferred adherence of monocytes occurs around intercostal orifices in normolipidemic and early cholesterol-fed rabbits before lesions develop at these lesion-prone sites. Monocyte deposition appears to be governed not only by the arterial flow field but also by cholesterol feeding since higher numbers of adherent monocytes were found on both early fatty streaks and nonlesioned endothelium in rabbits fed cholesterol for longer than 4 weeks.

Animals↗

Nd:YAG laser-welded canine arteriovenous anastomoses.

This preliminary report describes formation of femoral arterio-venous fistulas (n = 10) in six dogs using a 1.32-microns wavelength Nd:YAG laser welding technique. Stay sutures (6-0 polypropylene) were placed at 5-7 mm intervals along the anastomoses for vessel apposition. Delivery of laser energy through a 400-microns diameter fiber optic was controlled by a new computer-based software system. At 3 mm distance above the anastomosis, energy fluences of 110-260 J/mm2/cm length of anastomosis were used for laser welding. One or two additional hemostatic sutures were required in seven of the ten anastomoses. Flow was maintained for 1-2 hours prior to tissue harvesting. No thrombosis or delayed anastomotic failures were observed after initial welding and repair. Histologic examination revealed good apposition and adherence between wall layers and a fibrinous coagulum at the intimal junctions. Mild thermal injury of the wall was present at some anastomoses. This early investigation suggests that a 1.32 microns Nd:YAG laser welding technique can successfully create large vessel arteriovenous fistulas in the canine.

Animals↗

Intravascular ultrasound guidance for peripheral vascular interventions.

Intravascular ultrasound (IVUS) imaging during peripheral endovascular interventions adds important information regarding the distribution of disease by providing controlled measurements of the cross-sectional area of the vessel lumen and wall prior to and following procedures. IVUS is useful in determining the mechanism and efficacy of balloon angioplasty, in guiding atherectomy devices, and in assuring appropriate placement of intravascular stents. The incorporation of an IVUS element into catheter-based interventional devices may improve the immediate and long-term results of endovascular interventions by decreasing complications from dissection and perforation of the arterial wall. Combined IVUS-stent prototype catheters are being developed to enable imaging and deployment simultaneously. Similar devices are being explored to enhance expedient, precise delivery of endoluminal grafts. Future studies of endovascular techniques should include IVUS, when possible, to accurately quantitative the initial efficacy of devices and to determine the nature and distribution of recurrent lesions.

Angioplasty↗

Forward-looking intravascular ultrasonography: in vitro imaging of normal and atherosclerotic human arteries.

Inadequate guidance of angioplasty devices limits the endoluminal treatment of high grade atherosclerotic stenoses and total occlusions. Conventional intraluminal ultrasound systems (IVUS) enable lateral cross-sectional imaging of tomographic sections of the vessel wall, but do not offer imaging in front of the catheter. This study describes our initial experience with a forward-looking intravascular ultrasound (FL-IVUS) system (Echoeye, EchoCath, Inc., Princeton, NJ). The acoustic beam from a 25.5 MHz piezoelectric transducer on a 7.5 Fr catheter is mechanically rotated in a forward-looking spiral fashion at 300 cycles/second. Sixty-four axially aligned, cross-sectional, real time images are obtained from a truncated, 60 degree conical volume located 5 to 10 mm from the catheter tip. Luminal dimensions (n = 51) of human cadaveric femoral arteries (cast in agar and submerged in saline) measured by the FL-IVUS were compared to histologic cross-sections of the vessel with a correlation of r = 0.92. FL-IVUS accurately imaged the narrowing lumen in front of total occlusions and the geometry at vessel branches, and identified the location of lesions and the shape and morphology of vessel wall thickness. The 7.5 Fr FL-IVUS over-estimated luminal dimensions in vessels larger than 5 mm. We conclude that FL-IVUS imaging shows promise as a new, accurate method for identifying and characterizing high grade atherosclerotic stenoses and total occlusions, and expands the current capabilities of conventional IVUS systems.

Angioplasty, Balloon↗

Intravascular ultrasound imaging: the new standard for guidance and assessment of endovascular interventions?

Intravascular ultrasound has developed rapidly during the last few years, and provides a unique perspective from which to view vascular disease and the effects of intervention. This catheter-based imaging technique utilizes advances in echographic data processing and computerized image manipulation to produce accurate luminal and transmural images of blood vessels. Although these devices have only been available for a relatively short time, numerous diagnostic and therapeutic applications have been reported. By providing a detailed image of vessels before, during, and after intervention, intravascular ultrasound provides a method for both guidance of endoluminal devices and immediate assessment of the results of therapeutic techniques including balloon angioplasty, atherectomy, laser-assisted angioplasty, and intravascular stent deployment. Intravascular ultrasound also offers exciting possibilities in peripheral vascular research such as investigation of blood vessel compliance, dynamic changes in the vessel wall caused by disease or pharmacologic intervention, and elucidation of the morphologic changes associated with the natural history of atherosclerosis.

Angiography↗

Flow measurements in a human femoral artery model with reverse lumen curvature.

Flow visualization and wall pressure measurements were made in a smooth reverse curvature model that conformed to the gentle "s" shape of a left femoral artery angiogram of a patient in a clinical trial. Observed lesion localization at the inner (lesser) curvatures appeared to be associated with secondary flows in the wall vicinity directed toward the inner curvatures that tended to reverse direction in the flow entering the reverse curvature region. Moderate flow resistance increases of about 20 percent above the Poiseuille flow relation were found at the higher physiological Reynolds numbers Re above about 600-700 and thus Dean numbers for steady flow. For pulsatile flow simulation, flow resistances did not increase up to the largest Re of 470 tested. Apparently, the large variations in velocity during the cardiac cycle disrupted the stronger secondary flow patterns observed at the higher Reynolds numbers for steady flow.

Arteriosclerosis↗

Fluid particle motion and Lagrangian velocities for pulsatile flow through a femoral artery branch model.

A flow visualization study using selective dye injection and frame by frame analysis of a movie provided qualitative and quantitative data on the motion of marked fluid particles in a 60 degree artery branch model for simulation of physiological femoral artery flow. Physical flow features observed included jetting of the branch flow into the main lumen during the brief reverse flow period, flow separation along the main lumen wall during the near zero flow phase of diastole when the core flow was in the downstream direction, and inference of flow separation conditions along the wall opposite the branch later in systole at higher branch flow ratios. There were many similarities between dye particle motions in pulsatile flow and the comparative steady flow observations.

Adult↗

Fluid dynamic study in a femoral artery branch casting of man with upstream main lumen curvature for steady flow.

An in-vitro, steady flow investigation was conducted in a hollow, transparent vascular replica of the profunda femoris branch of man for a range of physiological flow conditions. The replica casting tested was obtained from a human cadaver and indicated some plaque formation along the main lumen and branch. The flow visualization observations and measured pressure distributions indicated the highly three-dimensional flow characteristics with arterial curvature and branching, and the important role of centrifugal effects in fluid transport mechanisms.

Blood Pressure↗

Primary axillary-subclavian venous thrombosis: is aggressive surgical intervention justified?

Multimodal (thrombolysis, surgical decompression, venous reconstruction, oral anticoagulation) treatment of primary axillary-subclavian venous thrombosis was reviewed to assess the impact of venous patency on functional outcome. Since 1996, 7 patients (6 men, 1 woman) of ages 16-53 years (mean 33 years) presented with symptomatic acute axillosubclavian venous thrombosis as a result of a recent athletic or strenuous arm activity. Five patients had undergone previous (>2 weeks) catheter-directed thrombolysis and venous angioplasty. Diagnostic contrast venography followed by repeat catheter-directed thrombolysis demonstrated abnormal (residual stenosis [n=6] or occlusion [n=1]) axillosubclavian venous segments in all patients. Surgical intervention was performed at a mean interval of 7 days (range 1-19 days) after thrombolysis and consisted of thoracic outlet decompression with scalenectomy and 1st rib resection via a paraclavicular (n=4) or supraclavicular (n=3) approach. Medial claviculectomy or cervical rib resection was performed in 2 patients. Concomitant venous surgery was performed in all patients to restore normal venous patency by circumferential venolysis (n=7) and balloon catheter thrombectomy (n=3), or vein-patch angioplasty (n=2), or endovenectomy (n=5), or internal jugular transposition (n=2). Postoperative venous duplex testing beyond 1 month identified recurrent thrombosis in 4 patients despite therapeutic oral anticoagulation. Subsequent venous recanalization was documented in 3 patients. Poor functional outcome was associated with an occluded venous repair and extensive venous thrombosis on initial presentation. A patent or recanalized venous repair present in 6 of 7 patients was associated with good functional outcome and may justify multimodal intervention in patients with primary axillosubclavian effort thrombosis presenting with recurrent thrombosis and significant residual disease after thrombolysis.

Adolescent↗