PubMed HealthSearch

Biomedical subjects

M R Horton

Publications and source records attributed to M R Horton.

10 recordsLinked to original sources

A review of algorithms for molecular sequence comparison.

Computers have recently become an essential component of research in molecular biology. Most computer analyses of nucleic acid and protein sequences depend on comparisons between sequences. These comparisons, depending on their purpose, may differ not only in the kinds of comparisons that are done, but also in the way the results of the comparison are used by molecular biologists or by other computer programs. This paper reviews algorithms currently in use to solve comparison problems in molecular biology. Each algorithm is explained in detail and discussed in terms of the molecular biology problems it is most suited to solve.

Algorithms

Nonparametric comparison of entire ROC curves for computerized ECG left ventricular hypertrophy algorithms using data from the Framingham Heart Study.

A computer program may be capable of several different statements for left ventricular hypertrophy (eg, possible LVH, probable LVH, consistent with LVH), but such statements resulting from discretized levels of sensitivity/specificity would represent only isolated points on a receiver-operating characteristic (ROC) curve, which is a plot of all levels of sensitivity versus specificity. Even if two algorithms use the same discrete scales, their performances may not readily be compared. The authors present a comparison methodology for ROC curves using ROC area as a nonparametric measure of the ability of the algorithm to separate the two populations; the ROC area ranges from 0.5 (no ability) to 1.0 (perfect separation) and is unbiased if the normal versus abnormal populations have no common values for the measurement. The methodology compares the performance of ECG algorithms on the same population of cases by testing for significant differences of ROC areas and incorporating correlation of the algorithms in a nonparametric way. To illustrate this methodology, they use ECG and echocardiographic data from the Framingham Heart Study.

Algorithms

Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter.

The purpose of this study was to design and test a bilinearly transformed, null-phase (BLT/NP) filter for removing baseline wander and to compare it with the cubic spline for performance. For this purpose, the ECG data were filtered to remove high-frequency noise and low-frequency baseline wander to form a set of "clean" ECGs. Artificial low-frequency noise mimicking typical baseline wander was constructed from sine and cosine waves at 0.20 and 0.45 Hz and with amplitudes of 400 and 300 microV, respectively, and added to the "clean" ECGs to form the "test" ECGs. The BLT/NP filter and the cubic spline method each were applied to a "test" ECG to form a "restored" ECG. The measure of performance was the root mean square difference (RMSD) between the "restored" ECG and the initial "clean" ECG. RMSD values showed that on the average the BLT/NP filter performed as well as the cubic spline method and has the advantage that accurate determination of the QRS onset is not required.

Algorithms

The emerging prominence of computer electrocardiography in large population-based surveys.

The year 1987 marks the centennial of electrocardiography. As Beamish reminds us, it was the first and foremost technical aid to the cardiologist. During the history of cardiovascular epidemiology, which dates back roughly forty years, electrocardiography has played a central role as a relatively specific marker for coronary and hypertensive heart disease. The lack of sensitivity of electrocardiography and the advent of new technologies such as ultrasonography for assessment of such heart disease in cardiology and cardiovascular epidemiology has raised questions as to whether electrocardiography might be replaced in the next century. Recent developments in computer electrocardiography have rendered suggestions of the decreased importance of electrocardiography premature. Use of computer analysis of electrocardiograms in epidemiologic studies, which dates back less than three decades, has renewed interest in and expanded the role of electrocardiography in cardiology in general and cardiovascular epidemiology in particular. The computer analysis of electrocardiograms has allowed the processing and analysis of large numbers of electrocardiograms in a rapid, efficient, systematic and consistent manner. This has led to new, more sensitive criteria for detection of left ventricular hypertrophy as a discrete variable. In addition, the numerous waveform amplitude and duration measurements by computer have allowed the development of mathematical models to express the likelihood of coronary heart disease (myocardial infarction) and degree of left ventricular hypertrophy (estimates of left ventricular mass) on continuous scales. These developments have contributed substantially to the potential of electrocardiography (and particularly computer electrocardiography) in future studies and clinical applications.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiomegaly

Electrocardiographic changes with advancing age. A cross-sectional study of the association of age with QRS axis, duration and voltage.

In order to examine the electrocardiographic (ECG) changes which occur with advancing age we defined an apparently healthy reference population derived from prospectively followed subjects of the Framingham Heart Study. Healthy subjects were clinically free of hypertension, coronary artery disease, congestive heart failure and valve disease and were not taking antihypertensive or other cardiac medications. ECG tracings were analyzed by the IBM Bonner (V2) program. Mean values and correlations with age for PR duration, QRS duration and axis, S wave voltage V1 and R wave voltage V5 are presented. With advancing age in men there is a narrowing of QRS, a leftward QRS axis shift, and a loss of S V1 and R V5 amplitude. In women only a leftward QRS axis shift is associated with advancing age. These changes should be considered in defining normal age- and sex-specific reference values. These findings underscore theoretical limitations of commonly-used criteria for the ECG diagnosis of conditions such as left ventricular hypertrophy.

Adult

Regional ventilatory clearance by xenon scintigraphy: a critical evaluation of two estimation procedures.

Estimates of ventilatory clearance are usually made by inspecting xenon washout images. Quantitative computer procedures have been described that produce regional clearance rates, yet their accuracy is not well established. We define a mathematical model for scintigraphic ventilation data based on 96 clinical studies, and with this model we test the accuracy of two procedures used to estimate ventilatory clearance. The least-squares curve-fitting technique for both washin and washout data has the same accuracy as a modified Stewart-Hamilton method (A/H) that uses washout data alone. Both procedures demonstrate relative errors of less than 5% and coefficients of variation of 10-20% when regions with equilibrium count rates of 3 cps and clearance times between 10 and 90 sec are examined. Because the A/H procedure is preferred for its simplicity and speed, we analyze two of its main sources of error: early washin/washout termination and background activity. To measure regional ventilation by the A/H procedure, we recommend: (a) washin and washout periods at least three times the largest clearance time of clinical interest; b) a regional equilibrium count rate of at least 3cps; and c) a 25- to 50-sec average of the equilibrium count rate.

Humans