A randomized trial of the long-term effects of digital ocular compression in the late postoperative period.

PURPOSE: To determine whether digital ocular compression is a viable technique to lower intraocular pressure in patients at least 3 months after trabeculectomy. PATIENTS AND METHODS: A 6-month prospective, randomized, controlled, single-masked trial of 29 patients who underwent a trabeculectomy at the Glaucoma Service of Wills Eye Hospital. Patients were assigned to two groups: ocular compression or cheekbone compression (control group). The ocular compression group performed compression to the operated eye three times a day in the pattern of 10 seconds of pressure, 5 seconds of rest, and 10 seconds of pressure. Pressure was applied with the index finger through the closed lid to the center of the cornea. Pressure was steady and firm, but not painful. No massaging was performed. The cheekbone compression group applied pressure to the zygomatic arch with an identical style and frequency. RESULTS: At 6 months, the change in mean intraocular pressure for the ocular compression group was 0.25 mm Hg compared with -0.44 mm Hg for the control group (P = 0.7). A few patients in both groups experienced large swings in intraocular pressure and mild to moderate discomfort. CONCLUSION: Ocular compression had little to no success in the long-term management of increased intraocular pressure in the late postoperative period in this study.

Aged↗

Trabeculectomy with intraoperative mitomycin C versus 5-fluorouracil. Prospective randomized clinical trial.

OBJECTIVE: To evaluate the relative efficacy and safety of 5-fluorouracil (5-FU) and mitomycin C (MMC) when used as adjuncts with primary trabeculectomy in eyes not at high risk for failure. DESIGN: Prospective multicenter, randomized clinical trial. PARTICIPANTS: One hundred thirteen patients with primary open-angle, pseudoexfoliative, pigmentary, or angle-closure glaucoma undergoing primary trabeculectomy were recruited. METHODS: One eye of each patient was randomized to receive either 5-FU (50 mg/ml for 5 minutes) or MMC (0.4 mg/ml for 2 minutes). MAIN OUTCOME MEASURES: Intraocular pressure (IOP), visual acuity, complications, and interventions were documented at fixed intervals after surgery. The study also examined progression of visual field loss, long-term complications, and bleb appearance 3 years after surgery. RESULTS: Of the 108 patients with complete perioperative information, 54 eyes received 5-FU and 54 received MMC. The proportion of patients reaching different predefined target IOPs after surgery was slightly higher in the MMC group than in the 5-FU group. This difference was less than 25%, which would have been necessary to achieve statistical significance with a power of 0.8 and the sample size used. Likewise, there was no statistically significant difference between the groups with regard to mean preoperative IOP, complications, or interventions. Mean postoperative follow-up was 309 and 330 days in the 5-FU and MMC groups, respectively (P = 0.593). CONCLUSIONS: 5-Fluorouracil and MMC were found to be equally safe and effective adjuncts to primary trabeculectomy in the short- and medium-term postoperative periods.

Aged↗

Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant.

PURPOSE: We studied the intermediate-term clinical experience with the Ahmed Glaucoma Valve implant (New World Medical, Inc, Rancho Cucamonga, California). METHODS: In this multicenter, retrospective case series, we studied 159 eyes (144 patients) treated with the Ahmed Glaucoma Valve with a mean +/- SEM (standard error of mean) follow-up of 13.4 +/- 0.7 months (range, 4 to 44 months). The mean +/- SEM age was 60.9 +/- 1.9 years (range, 0.1 to 103 years). Surgical success was defined as intraocular pressure less than 22 mm Hg and greater than 5 mm Hg without additional glaucoma surgery and without loss of light perception. Postoperative use of antiglaucoma medications was not a criterion for success or failure. The definition of hypotony was intraocular pressure of 5 mm Hg or less in two consecutive visits. RESULTS: Intraocular pressure was reduced from a mean of 32.7 +/- 0.8 mm Hg before surgery to 15.9 +/- 0.6 mm Hg (P < .0001) at the most recent follow-up after surgery. The number of antiglaucoma medications was decreased from 2.7 +/- 0.1 before surgery to 1.1 +/- 0.1 after surgery (P < .0001). The cumulative probability of success was 87% at 1 year and 75% at 2 years after surgery (Kaplan-Meier life-table analysis). Postoperatively, 24 (15%) of 159 eyes had intraocular pressure greater than or equal to 22 mm Hg. The visual acuity was improved or within one Snellen line in 131 eyes (82%). Complications occurred in 75 eyes (47%), the majority of which did not affect surgical outcome. The most common complication was obstruction of the tube, which was observed in 17 eyes (11%). Transient postoperative hypotony was found in 13 eyes (8%). CONCLUSIONS: The Ahmed Glaucoma Valve implant is effective in lowering intraocular pressure, and postoperative hypotony is not commonly associated with this implant.

Adolescent↗

Reversal of optic disc cupping after glaucoma surgery analyzed with a scanning laser tomograph.

OBJECTIVE: To detect and quantitate changes in optic nerve morphology after glaucoma surgery using the Heidelberg Retina Tomograph (HRT, Heidelberg Instruments, Heidelberg, Germany). DESIGN: Nonconsecutive observational case series. PARTICIPANTS AND INTERVENTION: The authors prospectively enrolled 21 adult patients undergoing incisional glaucoma surgery for progressive glaucoma damage. Quantitative analysis of the optic nerve head by scanning laser tomography and automated perimetry were performed before and after glaucoma surgery. MAIN OUTCOME MEASURES: Changes in optic nerve parameters were subjected to linear regression analysis with respect to percent of postoperative reduction of intraocular pressure (IOP), as well as with respect to age, refraction, preoperative cup:disc ratio, and change in visual field parameters. RESULTS: Seventeen patients had pre- and postoperative images suitable for analysis. Mean IOP at the time of image acquisition before surgery was 30.5+/-12 mm Hg, and after surgery 11.8+/-5.2 mm Hg (mean follow-up, 26+/-7 weeks). Eleven of 13 (85%) patients having IOP reduction of greater than 40% showed improvement in optic disc parameters. All four patients with less than 25% reduction in IOP showed worsening of most parameters. Changes in optic disc parameters were highly correlated with percent IOP reduction and with age. The parameters in which change most strongly correlated with percent change of IOP were cup area, rim area, cup:disc ratio, and mean cup depth (each, P<0.005). The age of the patient correlated highly with change in maximum cup depth (P<0.005). Refraction and clinically determined cup:disc ratio correlated poorly with changes in measured optic disc parameters. Clinical improvement in visual fields was correlated with the degree of improvement of cup:disc ratio (P = 0.025). CONCLUSION: Most patients showing a 40% lowering of IOP after glaucoma surgery show improved optic nerve morphology as measured by the HRT. The amount of improvement correlated highly with the percent reduction of IOP.

Adult↗

Transpupillary argon laser cyclophotocoagulation in the treatment of traumatic glaucoma.

PURPOSE: A patient with traumatic glaucoma who underwent transpupillary argon laser cyclophotocoagulation for management of uncontrolled intraocular pressure (IOP) despite maximally tolerated medical therapy is discussed. METHODS: In this patient, pars plana vitrectomy, lensectomy, and removal of 180 degrees of necrotic iris had been performed after a blunt trauma with a bungee cord. Six weeks after surgery, the patient presented with an IOP of 40 mmHg despite therapy with three aqueous suppressants. The patient refused further surgical intervention and opted for transpupillary argon laser cyclophotocoagulation (TALC). The laser setting was 1,000 mW, with a 50-micron spot size for 0.1 second. A total of 293 laser exposures through a Goldmann contact lens was administered to all visible ciliary processes over 180 degrees where iris structures were absent. RESULTS: Ten weeks after TALC, the patient's IOP remained controlled with medications at 16 mmHg, and visual acuity had improved to 20/25 with an aphakic contact lens. CONCLUSION: In selected patients whose ciliary processes are visible with indirect gonioscopy due to the defect in the iris, TALC may be an effective alternative cyclodestructive procedure to lower IOP when conventional medical or laser treatments are not successful.

Adult↗

The use of the consensual light reflex as an aid to performing laser peripheral iridectomy in patients with pigment dispersion syndrome and pigmentary glaucoma.

PURPOSE: The authors explore an alternative method of performing laser peripheral iridectomy (LPI) in patients with pigment dispersion syndrome and pigmentary glaucoma (PDS/PG) who are high myopes and therefore at increased risk of developing retinal detachment. METHODS: Four myopic patients with PDS/PG had LPI performed in one eye. A transilluminator was held up to the opposite eye to provide pupillary constriction via the consensual light reflex. No miotics were used. RESULTS: All LPIs were easily performed without complications. CONCLUSION: The authors present an alternative method to the standard use of pilocarpine for LPI theoretically to decrease further the incidence of retinal detachment in populations predisposed to it.

Accommodation, Ocular↗

Metipranolol-associated nongranulomatous anterior uveitis.

PURPOSE: To describe the findings in a patient with a nongranulomatous anterior uveitis, presumed to be induced by metipranolol. METHOD: A 69-year-old woman developed bilateral, nongranulomatous, anterior uveitis while undergoing treatment with metipranolol 0.3% for primary open-angle glaucoma. Four months after resolution of the initial episode, the patient was challenged with metipranolol 0.3% in the right eye. RESULT: On reinstituting metipranolol 0.3%, the patient once again developed a unilateral, nongranulomatous, anterior uveitis in the challenged eye. CONCLUSION: Metipranolol 0.3% eyedrops, used to treat primary open-angle glaucoma, appear to cause a nongranulomatous anterior uveitis.

Adrenergic beta-Antagonists↗

Quantitative differences between the optic nerve head and peripapillary retina in low-tension and high-tension primary open-angle glaucoma.

PURPOSE: To determine whether quantitative differences in optic nerve topography could be identified between patients having primary open-angle glaucoma with normal intraocular pressure (low-tension primary open-angle glaucoma [LT-POAG]) vs those with elevated intraocular pressure (high-tension primary open-angle glaucoma [HT-POAG]). METHODS: We attempted to match 31 eyes of 31 patients in the LT-POAG group on a case-by-case basis with comparable eyes of 31 patients with HT-POAG. We used the Heidelberg Retina Tomograph to evaluate the optic nerve head and retinal nerve fiber layer. RESULTS: Cup areas and cup:disk area ratios were significantly larger (P < .05), whereas rim areas, rim volumes, retinal nerve fiber layer heights, and retinal nerve fiber layer cross-sectional areas were consistently smaller, but not significantly so (P > .05), in the LT-POAG group. The inferior neuroretinal rim area was significantly smaller (P < .05) and the mean deviation of superior arcuate area was significantly greater than the opposite sector in patients with LT-POAG but not in those with HT-POAG. A relationship between localized measurements of the optic nerve head and mean deviation was more apparent in the LT-POAG group than in the HT-POAG group. CONCLUSIONS: The optic cups were larger in patients with LT-POAG than in those with HT-POAG. Measurements of sectors of the optic disk correlated better with visual field changes in LT-POAG than did global measurements of the whole nerve head, indicating more vulnerability of the optic nerve to focal damage with low intraocular pressure.

Case-Control Studies↗

Mitomycin-C supplemented trabeculectomy, phacoemulsification, and foldable lens implantation.

PURPOSE: To evaluate the outcome of combined mitomycin-C filtering surgery, phacoemulsification, and foldable intraocular lens (IOL) implantation. SETTING: Wills Eye Hospital, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. METHODS: This retrospective study evaluated 182 eyes of 174 patients who had combined mitomycin-C trabeculectomy, phacoemulsification, and insertion of a foldable IOL through a 3.5 mm incision. Success of the combined procedure was defined as intraocular pressure (IOP) below 21 mm Hg, with or without medications, and no serious complication. Success rates were calculated using the Kaplan-Meier actuarial method. RESULTS: Mean follow-up was 16.7 months +/- 5.4 (SD). The probability of success at 6, 12, 18, and 24 months was 98.3, 95.6, 90.6, and 88.0%, respectively. When compared with preoperatively, visual acuity improved one or more lines in 148 eyes (81.3%) and worsened one or more lines in 15 (8.2%); 111 eyes (61.0%) achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsule opacification requiring capsulotomy, which occurred in 22 cases (12.0%). CONCLUSION: The 1 year and 2 year IOP control rate of combined mitomycin-C filtering procedures and phacoemulsification in glaucoma patients was high.

Aged↗

A color Doppler analysis of nifedipine-induced posterior ocular blood flow changes in open-angle glaucoma.

PURPOSE: This pilot study used color Doppler imaging to investigate the effects of nifedipine on the posterior ocular blood flow of patients with glaucoma progression at normal intraocular pressures. PATIENTS AND METHODS: Eighteen patients, 11 men and seven women with a median age of 61.7 years, were imaged before and 6 weeks after the initiation of 30 mg of sustained-release nifedipine (Procardia XL; produced by either Pfizer or Pratt) daily. RESULTS: There was no statistically significant change in the blood velocity of the ophthalmic artery, central retinal artery, and main nasal and temporal short posterior ciliary arteries after treatment with nifedipine. CONCLUSION: The routine use of nifedipine in patients with normal tension glaucoma progression is not supported by this study.

Adult↗

Intraoperative prediction of intraocular pressure for the first postoperative day following glaucoma filtration surgery.

The goal of glaucoma filtering surgery is to achieve adequate control of intraocular pressure (IOP). This prospective study evaluates the authors' accuracy in predicting IOP for the first postoperative day (POD 1) through digital palpation of the globe and evaluation of the achieved leakage at the end of trabeculectomy. Fifty patients underwent trabeculectomy with or without the use of an antimetabolite. At the conclusion of the procedure, an IOP prediction for POD 1 was given by the surgeon. The recorded IOP readings on POD 1 were compared with this prediction. The results were evaluated by linear regression analysis. The IOP predictions were within +/- 3 mm Hg of the forecasted value for 31 patients (62%), within +/- 6 mm Hg for 44 patients (88%) and outside of +/- 6 mm Hg for 6 patients (12%). Short-term postoperative IOP control is reasonably predictable and may be adjusted for individual care.

Aqueous Humor↗

Encapsulated filtering blebs after trabeculectomy with mitomycin-C.

BACKGROUND AND OBJECTIVE: To determine the frequency of encapsulated blebs after guarded filtration procedures with mitomycin-C. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone a guarded filtration procedure with mitomycin-C. There were 235 patients (283 cases) who had more than 1 month of follow-up. RESULTS: An encapsulated bleb developed in 7 eyes (2.47%) of 6 patients. Identification of bleb encapsulation occurred at a mean follow-up time of 29.7 +/- 14.6 days after surgery. The mean intraocular pressure at that point was 24.2 +/- 13.5 mm Hg in the affected eyes. Three eyes were treated medically, and needling was performed in 4 eyes. CONCLUSION: There is a low frequency of encapsulated bleb formation after guarded filtration procedures with adjunctive mitomycin-C.

Administration, Topical↗

Subconjunctival versus peribulbar anesthesia in trabeculectomy: a prospective, randomized study.

BACKGROUND AND OBJECTIVE: To compare the use of subconjunctival and peribulbar anesthesia for trabeculectomy. PATIENTS AND METHODS: Sixty patients undergoing trabeculectomy were prospectively randomized to receive either peribulbar or subconjunctival anesthesia. Peribulbar anesthesia consisted of a 3-ml inferior and a 1-ml superior injection of a 1:1 mixture of 2% mepivacaine, 0.75% bupivacaine, and hyaluronidase. Subconjunctival anesthesia consisted of a 1- to 2-ml injection of the same mixture without hyaluronidase in the superotemporal quadrant. Intraoperative pain, presence of eye movements, and complications during surgery were evaluated. RESULTS: The frequency and intensity of pain was statistically similar between the two groups. All episodes of pain (20% in the subconjunctival group and 6.6% in the peribulbar group) were rated as mild. Eye movement was more common in the subconjunctival group than in the peribulbar group, but it was controlled by verbal command and did not interfere with the procedure. No clinically significant complications occurred during surgery. CONCLUSION: Subconjunctival anesthesia is an effective alternative to peribulbar anesthesia for trabeculectomy.

Aged↗

Simultaneous use of mitomycin-C with Baerveldt implantation.

BACKGROUND AND OBJECTIVE: To evaluate the outcome of Baerveldt implantation with adjunctive mitomycin-C in cases of complicated glaucoma. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone Baerveldt implantation with mitomycin-C between January 1993 and March 1995. Success was defined before data collection as an intraocular pressure (IOP) between 5 and 21 mm Hg, with or without medications. The success rate was calculated using the Kaplan-Meier actuarial method. RESULTS: Twenty-nine patients were identified. The mean preoperative IOP was 33.6 mm Hg, with an average of 2.0 antiglaucoma medications. The probability of success at 6 and 12 months for patients who received mitomycin-C during Baerveldt implantation was 82.4% and 73.3%, respectively. Choroidal effusion with a flat anterior chamber (10.3%), corneal edema (6.8%), and conjunctival erosion (6.8%) were the most frequent complications. CONCLUSION: In this retrospective series of complicated glaucoma, the implantation of a Baerveldt drainage device with adjunctive mitomycin-C had a satisfactory outcome. The complications encountered and the clinical efficacy were comparable to those of previously reported series in which mitomycin-C was not used.

Antibiotics, Antineoplastic↗

Formula revealed.

Explore the source record for details and available documents.

Antibiotics, Antineoplastic↗

Management of overfiltering and leaking blebs with autologous blood injection.

We describe our experience with intrableb autologous blood injection to manage over-filtering and leaking blebs. Autologous blood was injected into 12 thin cystic filtration blebs of 12 eyes. Indications for blood injection included symptomatic hypotony in five eyes, hypotony associated with bleb leakage in five eyes, and bleb leakage without hypotony in two eyes. Seven eyes (58.3%) were classified as successes and five eyes (41.7%) were classified as failures. The mean (+/- SD) follow-up was 6.8 +/- 2.6 months. Among the eyes classified as successes, a significant increase was noted in intraocular pressure and visual acuity by a mean (+/- SD) of 5.1 +/- 2.9 mm Hg and 5.3 +/- 2.1 lines, respectively. Bleb leakage resolved in four of seven eyes. The most common complication was hyphema formation. Injection of autologous blood into a filtration bleb is an alternative procedure for management of excessive filtration or bleb leakage in selected patients.

Adult↗