PubMed Health⌕ Search

Biomedical subjects

M R Piglionica

Publications and source records attributed to M R Piglionica.

6 recordsLinked to original sources

Endoluminal repair of infrarenal abdominal aortic aneurysms using a modular stent-graft: one-year clinical results from a European multicentre trial.

This is a report of a prospective study to evaluate the safety and efficacy of the Medtronic AneuRx stent-graft. Patients with an infrarenal aneurysm with a proximal neck length of greater than 10 mm and a neck diameter not greater than 26 mm and iliac artery diameters of at least 6 mm were accepted for endovascular repair using the Medtronic AneuRx modular stent-graft. A total of 104 patients were included in the study. Transfemoral placement of the bifurcated stent-graft was successful in 102 of 104 patients. Two conversions were performed. The mean operating time was 148 min (range 75-480) and the mean blood loss was 605 ml (range 100-2900). The mean follow-up was 15 months (range 12-21). Complications were rare and no kinking or migration occurred. At follow-up, four endoleaks persisted after 12 months. The Medtronic AneuRx stent-graft is a safe and efficacious alternative to open abdominal aortic aneurysm repair with excellent early results.

Aged↗

[Transluminal treatment in aneurysm of the abdominal aorta. Role of diagnostic imaging].

PURPOSE: To emphasize the importance of diagnostic imaging: a) in the selection of patients to be treated with the transluminal approach b) during stent-graft positioning c) in the follow-up of treated patients. MATERIAL AND METHODS: From January 1997 to May 1998, twenty-five patients with abdominal aortic aneurysms (AAA) were treated with transfemoral stent-grafts (AneuRx Medtronic). All patients were submitted to a preoperative study including digital angiography (DSA) and Spiral CT. Intraoperatively they underwent DSA and intravascular ultrasound (IVUS). Follow-up was performed with Spiral CT. RESULTS: Twenty-four bifurcated and one straight device were inserted in twenty-five patients with AAA. In two cases it was impossible to position the endoprosthesis due to narrow or tortuous artery access. Following the intention to treat criteria, the technical success rate was 92.5%. All the stents were patent and no dislodgement was observed at follow-up. Partial thrombosis of the stent was observed in three patients. Owing to incomplete distal covering, early endoleak occurred in one patient with an aortoiliac aneurysm; the positioning of two cuffs allowed a successful outcome. CT examination performed 6 months after positioning revealed the presence of endoleaks in three patients, due to persistence of lumbar and inferior mesenteric artery patency. The AAA was no more appreciable in five of the ten patients submitted to CT follow-up one year after the procedure. In three of ten cases it was reduced in size and in two patients there was no change. DISCUSSION: Spiral CT plays a basic role in the selection of patients because it helps assess the length and diameter of the proximal neck, thus permitting to choose the device to be inserted. Preoperative DSA is mandatory in the evaluation of size and tortuosity of the iliac arteries. IVUS allows to monitor the site of delivery during the maneuver and to make the final measurements while DSA plays a role in checking the correct positioning of the device and excluding the presence of endoleaks at the end of the procedure. Late follow-up with Spiral CT aims at demonstrating possible malfunctioning of the endoprosthesis and confirms the definitive exclusion of AAA. CONCLUSIONS: Diagnostic imaging plays a basic role in the endovascular treatment of AAA, much more than that required for traditional surgical treatment. In particular, pretreatment planning is critical and requires sophisticated imaging including Spiral CT with 3D reconstruction and angiographic evaluation using catheters with calibrated markers.

Angioplasty, Balloon↗

Carotid plaque characterization using digital image processing and its potential in future studies of carotid endarterectomy and angioplasty.

PURPOSE: To corroborate the validity of a computerized methodology for evaluating carotid lesions at risk for stroke based on plaque echogenicity. METHODS: The records of 96 carotid endarterectomy patients (59 men; median age 69.5 years, range 52 to 83) with stenoses > 50% were studied retrospectively. Forty-one patients (43%) had been symptomatic preoperatively. All patients had undergone computed tomography (CT) to detect infarction in the carotid territory and a duplex scan to measure carotid stenosis. Plaque echogenicity was analyzed by computer, expressing the echodensity in terms of the gray scale median (GSM). The incidence of CT-documented cerebral infarction was analyzed in relation to symptomatology, percent stenosis, and echodensity. RESULTS: Symptoms correlated well with CT evidence of brain infarction: 32% of symptomatic patients had a positive CT scan versus 16% for asymptomatic plaques (p = 0.076). The mean GSM value was 56 +/- 14 for plaques associated with negative CT scans and 38 +/- 13 for plaques from patients with positive scans (p < 0.0001). However, there was no difference in the GSM value between plaques with > or < 70% stenosis. Furthermore, the incidence of CT infarction was 40% in the cerebral territory of carotid plaques with a GSM value < 50 and only 9% in those with a GSM > 50 (p < 0.001). CONCLUSIONS: Computerized analysis of plaque echogenicity appears to provide clinically useful data that correlates with the incidence of cerebral infarction and symptoms. This method of analyzing plaque echolucency could be used as a screening tool for carotid stent studies to identify high-risk lesions better suited to conventional surgical treatment.

Aged↗

European multicentre experience with modular device (Medtronic Aneurx) for the endoluminal repair of infrarenal abdominal aortic aneurysms.

OBJECTIVE: Transfemoral endoluminal repair of AAA, introduced for the first time in the early 90's, has become a very promising alternative to conventional open repair and more and more centers are reporting satisfactory postoperative results in a high percentage of cases. Straight and bifurcated grafts represent the devices available on the market at present and aortic, as well as iliac aneurysmal lesions can be safely treated through a transfemoral approach. The possibility to indicate an endovascular AAA repair is related to the configuration (length and size) of the proximal and distal necks, tortuosity and calcification of the access arteries and to vascular and non-vascular comorbidities, which afflict the patients. The objective of our study was to evaluate the early and late postoperative results in a series of patients affected by infrarenal AAA, who underwent endoluminal repair. MATERIALS AND METHODS: From December 1996 to 31 October 1997 in 5 different European Centers, 100 Medtronic AneuRx bifurcated stent grafts were implanted for infrarenal abdominal aortic aneurysms. The diameter of the AAA varied from 33 to 77 mm (average 64 mm) and the mean age of the patients was 70.8 years (51-87 years). In one patient with a 33 mm diameter of the aneurysm, the surgical procedure was indicated because the size of the aneurysm had increased by 5 mm, compared to the previous control made 2 months before. In addition the aneurysm became symptomatic. There were 92 male and 8 female patients. The average time of the surgical procedure was 150 minutes (75-480 minutes) with an average blood loss of 570 ml (100-2,600 ml).

Aged↗

[Subrenal aortic occlusion].

The juxtarenal aortic occlusion is an infrequent but not exceptional condition determining several problems during the corrective procedure. The incidence of this pathological picture is around 10% of the patients affected by steno-obliterative lesions of the subrenal aorta. The danger of this morbid condition derives mainly from the risks threatening the renal function which sometimes is already endangered before surgical intervention. The operation however implies high additional risks because some surgical procedures require suprarenal aortic clamping and because during the surgical manoeuvres embolization could occur in the lumen of renal arteries. This study analyzes 206 patients who underwent surgical intervention for subrenal aortic occlusion during the last 15 years. 11 patients were operated on in emergency because of lower limbs ischaemia. 4 patients presented a complete thrombosis of an aneurysmatic lesion of the subrenal aorta. The study is aimed at analyzing the renal behaviour in the postoperative period, comparing its functionality with the preoperative parameters. A second aspect which will be considered refers to the type of surgical procedure.

Adult↗

New diagnostic and screening possibilities in the stenobliterative lesions of the deep visceral vessels.

The evolution and continuous improvement of the ultrasonic diagnostic devices allows an hemodynamic and morphological exploration of the deep abdominal vessels that until now seemed to be precluded to non invasive diagnostic techniques. For example, the angiodynography today advantageously substitutes classical urographic investigation during the initial screening of the hypertensive patients suspected of stenotic lesions of the renal arteries. In fact the ecocolordopplersonography allows not only a morphological evaluation of the parenchyma and of the renal vascular tree, but also supplies a quantitative measurement of the blood flow through the renal artery. Still more important are the possibilities offered by these devices in the study of the acute or chronic intestinal ischemia, in which until now a sure diagnosis was only possible using invasive techniques. Performing a study of the mesenteric vascularization urgently, sometimes is possible a decisive demonstration of an ischemic pathology where the clinical abdominal picture provides only uncertain diagnostic elements.

Abdomen↗