Evaluation of disinfection techniques for, and their effects on, rectal thermocouple catheters.

The antibacterial activities of an iodophor (Wescodyne G), a quaternary ammonium compound (Roccal), and an iodine tincture as agents for the cold disinfection of rectal catheters contaminated in vitro were determined. Following thorough cleaning with an alcoholic solution of soft soap, each of the three disinfectants tested showed satisfactory results (100% kill) in 5 min against the enteric test bacteria (Escherichia coli and Salmonella typhosa) as well as a test species of the genus Pseudomonas, among the bacteria most resistant to surface-active agents. An aqueous solution of Wescodyne G containing 75 ppm available iodine was used both as a wiping solution and for subsequent disinfection of rectal catheters contaminated in vivo. Total bacterial destruction was found to follow a 60-min soak preceded by the wiping procedure. Rectal catheters subjected to prolonged immersion in each of the test disinfectants were found to be essentially unaffected, retaining their initial calibrations within a permissible tolerance. Neither Roccal nor Wescodyne G solutions were found to measurably attack bare thermocouples. Alcoholic iodine 0.5% did, however, exert a deteriorating effect on bare thermocouples in a short time, as measured by change in resistance characteristics. The results of this study have led to the recommendation that Wescodyne G containing 75 ppm available iodine be used in standing operating procedures for the initial cleaning and subsequent disinfection of rectal thermocouple catheters.

Benzalkonium Compounds↗

A practical approach to evaluation of the germicidal efficiency of a general purpose military disinfectant.

The bactericidal activity of a general purpose disinfectant consisting of 25% sodium-o-phenylphenolate and 75% sodium-4- and 6-chloro-2-phenylphenolate was evaluated by a simulated in-use, surface-square dilution method. Common floor (asphalt, rubber, and unglazed tiles) and wall (stainless steel tile, ceramic tile, and painted wood) surfaces of various porosities and compositions were selected to simulate actual-use conditions. The method used consisted of inoculating the surfaces of 1-in. square sections of floor and wall covering with a test organism, air-drying the inoculated surface, applying the disinfectant, allowing it to act for 10 min, and recovering the survivors by plating. Confirmatory results of the standard phenol coefficient and use-dilution tests indicated 700 ppm of the disinfectant to be a safe use concentration. The in-use surface-square dilution studies have shown that this is a more than adequate safe concentration for stainless steel, both glazed and unglazed ceramic tile, and nonwaxed surface of asphalt tile. However, concentrations ranging between 2,500 and 6,000 ppm for plastic-fortified rubber tile, 1,500 and 2,000 ppm for waxed asphalt tile, and 2,000 ppm for painted wood were required to achieve 99.9% reduction of either Salmonella choleraesuis or Salmonella schottmuelleri. These results indicate that a disinfectant concentration derived from the Association of Official Agricultural Chemists use-dilution test cannot always be relied upon to provide a dependable index to actual safe use-dilution when a disinfectant is supplied to certain wall or floor surfaces.

Anti-Infective Agents, Local↗